Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 711
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 24(26): 7972-7978, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38888269

RESUMO

Despite the weak, van der Waals interlayer coupling, photoinduced charge transfer vertically across atomically thin interfaces can occur within surprisingly fast, sub-50 fs time scales. An early theoretical understanding of charge transfer is based on a noninteracting picture, neglecting excitonic effects that dominate optical properties of such materials. We employ an ab initio many-body perturbation theory approach, which explicitly accounts for the excitons and phonons in the heterostructure. Our large-scale first-principles calculations directly probe the role of exciton-phonon coupling in the charge dynamics of the WS2/MoS2 heterobilayer. We find that the exciton-phonon interaction induced relaxation time of photoexcited excitons at the K valley of MoS2 and WS2 is 67 and 15 fs at 300 K, respectively, which sets a lower bound to the intralayer-to-interlayer exciton transfer time and is consistent with experiment reports. We further show that electron-hole correlations facilitate novel transfer pathways that are otherwise inaccessible to noninteracting electrons and holes.

2.
Neuroimage ; 288: 120523, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38278427

RESUMO

Although manganese (Mn) is a trace metal essential for humans, chronic exposure to Mn can cause accumulation of this metal ion in the brain leading to an increased risk of neurological and neurobehavioral health effects. This is a concern for welders exposed to Mn through welding fumes. While brain Mn accumulation in occupational settings has mostly been reported in the basal ganglia, several imaging studies also revealed elevated Mn in other brain areas. Since Mn functions as a magnetic resonance imaging (MRI) T1 contrast agent, we developed a whole-brain MRI approach to map in vivo Mn deposition differences in the brains of non-exposed factory controls and exposed welders. This is a cross-sectional analysis of 23 non-exposed factory controls and 36 exposed full-time welders from the same truck manufacturer. We collected high-resolution 3D MRIs of brain anatomy and R1 relaxation maps to identify regional differences using voxel-based quantification (VBQ) and statistical parametric mapping. Furthermore, we investigated the associations between excess Mn deposition and neuropsychological and motor test performance. Our results indicate that: (1) Using whole-brain MRI relaxometry methods we can generate excess Mn deposition maps in vivo, (2) excess Mn accumulation due to occupational exposure occurs beyond the basal ganglia in cortical areas associated with motor and cognitive functions, (3) Mn likely diffuses along white matter tracts in the brain, and (4) Mn deposition in specific brain regions is associated with exposure (cerebellum and frontal cortex) and motor metrics (cerebellum and hippocampus).


Assuntos
Manganês , Ferreiros , Humanos , Estudos Transversais , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Mapeamento Encefálico
3.
Small ; 20(5): e2305360, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37786291

RESUMO

Thermoelectric (TE) building materials have the potential to revolutionize sustainable architecture by converting temperature differences into electrical energy. This study introduces geopolymeric TE materials enhanced with manganese dioxide (MnO2 ) as a modifying agent. Calorimetric experiments examine the impact of MnO2 on geopolymerization. Mechanical tests show that adding MnO2 (up to 5% by weight) improves the geopolymer composite's strength, achieving a peak compressive strength of 36.8 MPa. The Seebeck effect of the MnO2 -modified geopolymeric composite is also studied. The inclusion of MnO2 boosts the Seebeck coefficient of the geopolymer, reaching a notable 4273 µV C-1 at a 5% MnO2 dosage. This enhancement is attributed to an increase in the density of states (DOS) and a reduction in relaxation time. However, excessive MnO2 or high alkali levels may adversely affect the Seebeck coefficient by lengthening the relaxation time.

4.
Small ; 20(27): e2309600, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38403846

RESUMO

Constructing a stable and robust solid electrolyte interphase (SEI) has a decisive influence on the charge/discharge kinetics of lithium-ion batteries (LIBs), especially for silicon-based anodes which generate repeated destruction and regeneration of unstable SEI films. Herein, a facile way is proposed to fabricate an artificial SEI layer composed of lithiophilic chitosan on the surface of two-dimensional siloxene, which has aroused wide attention as an advanced anode for LIBs due to its special characteristics. The optimized chitosan-modified siloxene anode exhibits an excellent reversible cyclic stability of about 672.6 mAh g-1 at a current density of 1000 mA g-1 after 200 cycles and 139.9 mAh g-1 at 6000 mA g-1 for 1200 cycles. Further investigation shows that a stable and LiF-rich SEI film is formed and can effectively adhere to the surface during cycling, redistribute lithium-ion flux, and enable a relatively homogenous lithium-ion diffusion. This work provides constructive guidance for interface engineering strategy of nano-structured silicon anodes.

5.
Magn Reson Med ; 91(5): 1863-1875, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38192263

RESUMO

PURPOSE: To evaluate a vendor-agnostic multiparametric mapping scheme based on 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) for whole-brain T1, T2, and proton density (PD) mapping. METHODS: This prospective, multi-institutional study was conducted between September 2021 and February 2022 using five different 3T systems from four prominent MRI vendors. The accuracy of this technique was evaluated using a standardized MRI system phantom. Intra-scanner repeatability and inter-vendor reproducibility of T1, T2, and PD values were evaluated in 10 healthy volunteers (6 men; mean age ± SD, 28.0 ± 5.6 y) who underwent scan-rescan sessions on each scanner (total scans = 100). To evaluate the feasibility of 3D-QALAS, nine patients with multiple sclerosis (nine women; mean age ± SD, 48.2 ± 11.5 y) underwent imaging examination on two 3T MRI systems from different manufacturers. RESULTS: Quantitative maps obtained with 3D-QALAS showed high linearity (R2 = 0.998 and 0.998 for T1 and T2, respectively) with respect to reference measurements. The mean intra-scanner coefficients of variation for each scanner and structure ranged from 0.4% to 2.6%. The mean structure-wise test-retest repeatabilities were 1.6%, 1.1%, and 0.7% for T1, T2, and PD, respectively. Overall, high inter-vendor reproducibility was observed for all parameter maps and all structure measurements, including white matter lesions in patients with multiple sclerosis. CONCLUSION: The vendor-agnostic multiparametric mapping technique 3D-QALAS provided reproducible measurements of T1, T2, and PD for human tissues within a typical physiological range using 3T scanners from four different MRI manufacturers.


Assuntos
Encéfalo , Esclerose Múltipla , Masculino , Humanos , Feminino , Reprodutibilidade dos Testes , Estudos Prospectivos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Esclerose Múltipla/diagnóstico por imagem , Mapeamento Encefálico
6.
NMR Biomed ; : e5172, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38794994

RESUMO

Limb-girdle muscular dystrophy (LGMD) type R1 (LGMDR1) is the most common subtype of LGMD in Europe. Prospective longitudinal data, including clinical assessments and new biomarkers such as quantitative magnetic resonance imaging (qMRI), are needed to evaluate the natural course of the disease and therapeutic options. We evaluated eight thigh and seven leg muscles of 13 LGMDR1 patients (seven females, mean age 36.7 years, body mass index 23.9 kg/m2) and 13 healthy age- and gender-matched controls in a prospective longitudinal design over 1 year. Clinical assessment included testing for muscle strength with quick motor function measure (QMFM), gait analysis and patient questionnaires (neuromuscular symptom score, activity limitation [ACTIVLIM]). MRI scans were performed on a 3-T MRI scanner, including a Dixon-based sequence, T2 mapping and diffusion tensor imaging. The qMRI values of fat fraction (FF), water T2 relaxation time (T2), fractional anisotropy, mean diffusivity, axial diffusivity and radial diffusivity were analysed. Within the clinical outcome measures, significant deterioration between baseline and follow-up was found for ACTIVLIM (p = 0.029), QMFM (p = 0.012). Analysis of qMRI parameters of the patient group revealed differences between time points for both FF and T2 when analysing all muscles (FF: p < 0.001; T2: p = 0.016). The highest increase of fat replacement was found in muscles with an FF of between 10% and 50% at baseline. T2 in muscles with low-fat replacement increased significantly. No significant differences were found for the diffusion metrics. Significant correlations between qMRI metrics and clinical assessments were found at baseline and follow-up, while only T2 changes in thigh muscles correlated with changes in ACTIVLIM over time (ρ = -0.621, p < 0.05). Clinical assessments can show deterioration of the general condition of LGMDR1 patients. qMRI measures can give additional information about underlying pathophysiology. Further research is needed to establish qMRI outcome measures for clinical trials.

7.
J Magn Reson Imaging ; 59(2): 699-710, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37209407

RESUMO

BACKGROUND: Clear cell renal cell carcinoma (ccRCC) is the most common subtype of RCC, and accurate grading is crucial for prognosis and treatment selection. Biopsy is the reference standard for grading, but MRI methods can improve and complement the grading procedure. PURPOSE: Assess the performance of diffusion relaxation correlation spectroscopic imaging (DR-CSI) in grading ccRCC. STUDY TYPE: Prospective. SUBJECTS: 79 patients (age: 58.1 +/- 11.5 years; 55 male) with ccRCC confirmed by histopathology (grade 1, 7; grade 2, 45; grade 3, 18; grade 4, 9) following surgery. FIELD STRENGTH/SEQUENCE: 3.0 T MRI scanner. DR-CSI with a diffusion-weighted echo-planar imaging sequence and T2-mapping with a multi-echo spin echo sequence. ASSESSMENT: DR-CSI results were analyzed for the solid tumor regions of interest using spectrum segmentation with five sub-region volume fraction metrics (VA , VB , VC , VD , and VE ). The regulations for spectrum segmentation were determined based on the D-T2 spectra of distinct macro-components. Tumor size, voxel-wise T2, and apparent diffusion coefficient (ADC) values were obtained. Histopathology assessed tumor grade (G1-G4) for each case. STATISTICAL TESTS: One-way ANOVA or Kruskal-Wallis test, Spearman's correlation (coefficient, rho), multivariable logistic regression analysis, receiver operating characteristic curve analysis, and DeLong's test. Significance criteria: P < 0.05. RESULTS: Significant differences were found in ADC, T2, DR-CSI VB , and VD among the ccRCC grades. Correlations were found for ccRCC grade to tumor size (rho = 0.419), age (rho = 0.253), VB (rho = 0.553) and VD (rho = -0.378). AUC of VB was slightly larger than ADC in distinguishing low-grade (G1-G2) from high-grade (G3-G4) ccRCC (0.801 vs. 0.762, P = 0.406) and G1 from G2 to G4 (0.796 vs. 0.647, P = 0.175), although not significant. Combining VB , VD , and VE had better diagnostic performance than combining ADC and T2 for differentiating G1 from G2-G4 (AUC: 0.814 vs 0.643). DATA CONCLUSION: DR-CSI parameters are correlated with ccRCC grades, and may help to differentiate ccRCC grades. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Estudos Prospectivos , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos , Gradação de Tumores , Estudos Retrospectivos
8.
Cereb Cortex ; 33(7): 3562-3574, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-35945683

RESUMO

Quantitative magnetic resonance (MR) has been used to study cyto- and myelo-architecture of the human brain non-invasively. However, analyzing brain cortex using high-resolution quantitative MR acquisition can be challenging to perform using 3T clinical scanners. MR fingerprinting (MRF) is a highly efficient and clinically feasible quantitative MR technique that simultaneously provides T1 and T2 relaxation maps. Using 3D MRF from 40 healthy subjects (mean age = 25.6 ± 4.3 years) scanned on 3T magnetic resonance imaging, we generated whole-brain gyral-based normative MR relaxation atlases and investigated cortical-region-based T1 and T2 variations. Gender and age dependency of T1 and T2 variations were additionally analyzed. The coefficient of variation of T1 and T2 for each cortical-region was 3.5% and 7.3%, respectively, supporting low variability of MRF measurements across subjects. Significant differences in T1 and T2 were identified among 34 brain regions (P < 0.001), lower in the precentral, postcentral, paracentral lobule, transverse temporal, lateral occipital, and cingulate areas, which contain sensorimotor, auditory, visual, and limbic functions. Significant correlations were identified between age and T1 and T2 values. This study established whole-brain MRF T1 and T2 atlases of healthy subjects using a clinical 3T scanner, which can provide a quantitative and region-specific baseline for future brain studies and pathology detection.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Adulto Jovem , Adulto , Lactente , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Voluntários Saudáveis , Processamento de Imagem Assistida por Computador/métodos
9.
Proc Natl Acad Sci U S A ; 118(15)2021 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-33837153

RESUMO

Colloidal gels result from the aggregation of Brownian particles suspended in a solvent. Gelation is induced by attractive interactions between individual particles that drive the formation of clusters, which in turn aggregate to form a space-spanning structure. We study this process in aluminosilicate colloidal gels through time-resolved structural and mechanical spectroscopy. Using the time-connectivity superposition principle a series of rapidly acquired linear viscoelastic spectra, measured throughout the gelation process by applying an exponential chirp protocol, are rescaled onto a universal master curve that spans over eight orders of magnitude in reduced frequency. This analysis reveals that the underlying relaxation time spectrum of the colloidal gel is symmetric in time with power-law tails characterized by a single exponent that is set at the gel point. The microstructural mechanical network has a dual character; at short length scales and fast times it appears glassy, whereas at longer times and larger scales it is gel-like. These results can be captured by a simple three-parameter constitutive model and demonstrate that the microstructure of a mature colloidal gel bears the residual skeleton of the original sample-spanning network that is created at the gel point. Our conclusions are confirmed by applying the same technique to another well-known colloidal gel system composed of attractive silica nanoparticles. The results illustrate the power of the time-connectivity superposition principle for this class of soft glassy materials and provide a compact description for the dichotomous viscoelastic nature of weak colloidal gels.

10.
Sensors (Basel) ; 24(10)2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38793913

RESUMO

The purpose of this paper is to demonstrate a new discovery regarding the interaction between materials and very low radio frequencies. Specifically, we observed a feedback response on an inertia active sensor when specific frequencies (around 2-4 kHz) are used to irradiate targeted pharmaceutical samples like aspirin or paracetamol drugs. The characteristics of this phenomenon, such as excitation and relaxation time, the relation between deceleration and a material's quantity, and signal amplitude, are presented and analyzed. Although the underlying physics of this phenomenon is not yet known, we have shown that it has potential applications in remote identification of compounds, detection, and location sensing, as well as identifying substances that exist in plants without the need for any processing. This method is fast, accurate, low-cost, non-destructive, and non-invasive, making it a valuable area for further research that could yield spectacular results in the future.


Assuntos
Acetaminofen , Acetaminofen/análise , Acetaminofen/química , Fenômenos Eletromagnéticos , Aspirina/química , Aspirina/análise , Preparações Farmacêuticas/química , Preparações Farmacêuticas/análise , Ondas de Rádio
11.
J Therm Biol ; 119: 103777, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38150888

RESUMO

The aim of this work is to analytically study the thermo-mechanical response of two-dimensional skin tissues when subjected to instantaneous heating. A complete understanding of the heat transfer process and the associated thermal and mechanical effects on the patient's skin tissues is critical to ensuring the effective applications of thermal therapy techniques and procedures. The surface boundary of the half-space undergoes a heat flux characterized by an exponentially decaying pulse, while maintaining a condition of zero traction. The utilization of Laplace and Fourier transformations is employed, and the resulting formulations are then applied to human tissues undergoing regional hyperthermia treatment for cancer therapy. To perform the inversion process for Laplace and Fourier transforms, a numerical programming method based on Stehfest numerical inverse method is employed. The findings demonstrate that blood perfusion rate and thermal relaxation time significantly influence all the analyzed distributions. Numerical findings suggest that thermo-mechanical waves propagate through skin tissue over finite distances, which helps mitigate the unrealistic predictions made by the Pennes' model.


Assuntos
Hipertermia Induzida , Modelos Biológicos , Humanos , Condutividade Térmica , Pele , Hipertermia Induzida/métodos , Temperatura Cutânea , Temperatura Alta
12.
Alzheimers Dement ; 20(3): 2047-2057, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38184796

RESUMO

INTRODUCTION: Mapping of microscopic changes in the perivascular space (PVS) of the cerebral cortex, beyond magnetic resonance-visible PVS in white matter, may enhance our ability to diagnose Alzheimer's disease (AD) early. METHODS: We used the cerebrospinal fluid (CSF) water fraction (CSFF), a magnetic resonance imaging-based biomarker, to characterize brain parenchymal CSF water, reflecting microscopic PVS in parenchyma. We measured CSFF and amyloid beta (Aß) using 11 C Pittsburgh compound B positron emission tomography to investigate their relationship at both the subject and voxel levels. RESULTS: Our research has demonstrated a positive correlation between the parenchymal CSFF, a non-invasive imaging biomarker indicative of parenchymal glymphatic clearance, and Aß deposition, observed at both individual and voxel-based assessments in the posterior cingulate cortex. DISCUSSION: This study shows that an increased parenchymal CSFF is associated with Aß deposition, suggesting that CSFF could serve as a biomarker for brain glymphatic clearance, which can be used to detect early fluid changes in PVS predisposing individuals to the development of AD. HIGHLIGHTS: Cerebrospinal fluid fraction (CSFF) could be a biomarker of parenchymal perivascular space. CSFF is positively associated with amyloid beta (Aß) deposition at subject level. CSFF in an Aß+ region is higher than in an Aß- region in the posterior cingulate cortex. Correspondence is found between Aß deposition and glymphatic clearance deficits measured by CSFF.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Humanos , Peptídeos beta-Amiloides/metabolismo , Doença de Alzheimer/patologia , Encéfalo/patologia , Tomografia por Emissão de Pósitrons/métodos , Biomarcadores , Água
13.
Molecules ; 29(2)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38257380

RESUMO

The viscoelastic behaviors of aqueous solutions of commercially available methyl cellulose (MC) samples with a degree of substitution of 1.8 and a wide range of weight average molar masses (Mw) were investigated over a wide concentration (c) range at some temperatures from -10 to 25 °C. The viscoelastic parameters useful to discuss the structure and dynamics of MC-forming particles in aqueous solutions were precisely determined, such as the zero-shear viscosity (η0), the steady-state compliance (Je), the average relaxation time (τw), and the activation energy (E*) of τw. Because previously obtained scattering and intrinsic viscosity ([η]) data revealed that the MC samples possess a rigid rod-like structure in dilute aqueous solutions over the entire Mw range examined, the viscoelastic data obtained in this study were discussed in detail based on the concept of rigid rod particle suspension rheology. The obtained Je-1 was proportional to the number density of sample molecules (ν = cNAMw-1, where NA means the Avogadro's constant) over the ν range examined irrespective of Mw. The reduced relaxation time (4NAτw(3νJe [η]ηmMw)-1), where ηm means the medium viscosity, was proportional to (νL3)2, L; the average particle length depending on Mw for each sample was determined in a previous study; and the reduced specific viscosity (ηspNAL3(Mw [η])-1), where ηsp means the specific viscosity, was proportional to (νL3)3 in a range of νL3 < 3 × 102. These findings were typical characteristics of the rigid rod suspension rheology. Therefore, the MC samples behave as entangling rigid rod particles in the νL3 range from rheological points of view. A stepwise increase in E* was clearly observed in a c range higher than the [η]-1 value irrespective of Mw. This observation proposes that contact or entanglement formation between particles formed by MC molecules results in an increase in E*.

14.
Molecules ; 29(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38398549

RESUMO

The iminosugar 1-deoxynojirimicyn (DNJ) contained in mulberry leaves has displayed systemic beneficial effects against disorders of carbohydrate metabolism. Nevertheless, its effect is impaired by the short half-life. Alginate-based carriers were developed to encapsulate a DNJ-rich mulberry extract: Ca-alginate beads, obtained by external gelation, and spray-dried alginate microparticles (SDMs). Mean size and distribution, morphology, drug loading, encapsulation efficiency, experimental yield, and release characteristics were determined for the two formulations. Ca-alginate beads and SDMs exhibited an encapsulation efficiency of about 54% and 98%, respectively, and a DNJ loading in the range of 0.43-0.63 µg/mg. The in vitro release study demonstrated the carriers' capability in controlling the DNJ release in acid and basic conditions (<50% in 5 h), due to electrostatic interactions, which were demonstrated by 1H-NMR relaxometry studies. Thus, alginate-based particles proved to be promising strategies for producing food supplements containing mulberry leaf extracts for the management of hyperglycemic state.


Assuntos
Alginatos , Morus , Alginatos/metabolismo , 1-Desoxinojirimicina/química , Morus/química , Suplementos Nutricionais , Extratos Vegetais/química , Folhas de Planta/metabolismo
15.
Hippocampus ; 33(11): 1189-1196, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37587770

RESUMO

Mesial temporal lobe epilepsy is one of the most common causes of refractory epilepsy worldwide. A good percentage of patients do not have detectable hippocampal atrophy on magnetic resonance imaging (MRI). The objective of this study is to evaluate whether T2 relaxometry can identify hippocampal pathology and lateralize the epileptic focus in patients with intractable temporal lobe epilepsy (TLE). T2 relaxometry can also be used to correlate the clinical severity of the disease with the relaxometry readings in those who have hippocampal atrophy as well as those who do not. Thirty two patients having clinical and electrophysiological features of TLE were enrolled and a MRI brain with T2 relaxometry was done. Hippocampal T2 relaxometry values were calculated in the head, body, and tail of the hippocampus and average T2 relaxometry values were calculated, and a comparison was done with the controls. For patients with unilateral involvement, the contralateral side was taken as control and in cases of bilateral involvement, controls were identified from normal subjects. T2 relaxometry is found to be superior to MR visual analysis in the early detection of cases of hippocampal sclerosis where there is no atrophy on visual analysis. Nine out of 32 patients (28%) were normal on MR visual analysis; however, showed increased values on T2 relaxometry, correlating with clinical and electrophysiological diagnosis. The rest of the patients with hippocampal atrophy showed a correlation of T2 relaxometry values with the degree of atrophy. The hippocampal T2 measurement is thus more sensitive and specific. The study was clinically significant (p < .0001). There was a mild female predilection of the disease and there was no significant correlation with comorbidities. There was a strong positive correlation with patients having a history of febrile seizures in childhood. T2 relaxometry may accurately lateralize the majority of patients with persistent TLE and offers evidence of hippocampus injury in those patients who do not show evidence of atrophy on MRI and also the T2 relaxometry values correlated with the degree of atrophy. Early identification of hippocampal sclerosis is crucial for prompt management which offers better outcomes.


Assuntos
Epilepsia do Lobo Temporal , Esclerose Hipocampal , Doenças Neurodegenerativas , Humanos , Feminino , Epilepsia do Lobo Temporal/diagnóstico por imagem , Epilepsia do Lobo Temporal/patologia , Estudos Transversais , Hipocampo/diagnóstico por imagem , Hipocampo/patologia , Imageamento por Ressonância Magnética/métodos , Doenças Neurodegenerativas/patologia , Atrofia , Esclerose/diagnóstico por imagem , Esclerose/patologia
16.
Magn Reson Med ; 90(5): 1990-2000, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37345717

RESUMO

PURPOSE: Postexercise recovery rate is a vital component of designing personalized training protocols and rehabilitation plans. Tracking exercise-induced muscle damage and recovery requires sensitive tools that can probe the muscles' state and composition noninvasively. METHODS: Twenty-four physically active males completed a running protocol consisting of a 60-min downhill run on a treadmill at -10% incline and 65% of maximal heart rate. Quantitative mapping of MRI T2 was performed using the echo-modulation-curve algorithm before exercise, and at two time points: 1 h and 48 h after exercise. RESULTS: T2 values increased by 2%-4% following exercise in the primary mover muscles and exhibited further elevation of 1% after 48 h. For the antagonist muscles, T2 values increased only at the 48-h time point (2%-3%). Statistically significant decrease in the SD of T2 values was found following exercise for all tested muscles after 1 h (16%-21%), indicating a short-term decrease in the heterogeneity of the muscle tissue. CONCLUSION: MRI T2 relaxation time constitutes a useful quantitative marker for microstructural muscle damage, enabling region-specific identification for short-term and long-term systemic processes, and sensitive assessment of muscle recovery following exercise-induced muscle damage. The variability in T2 changes across different muscle groups can be attributed to their different role during downhill running, with immediate T2 elevation occurring in primary movers, followed by delayed elevation in both primary and antagonist muscle groups, presumably due to secondary damage caused by systemic processes.


Assuntos
Músculo Esquelético , Corrida , Masculino , Humanos , Músculo Esquelético/diagnóstico por imagem , Corrida/fisiologia , Exercício Físico , Imageamento por Ressonância Magnética/métodos
17.
Magn Reson Med ; 90(1): 11-20, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36807934

RESUMO

PURPOSE: The purpose of this study was to characterize the 1 H downfield MR spectrum from 8.0 to 10.0 ppm of human skeletal muscle at 7 T and determine the T1 and cross-relaxation rates of observed resonances. METHODS: We performed downfield MRS in the calf muscle of 7 healthy volunteers. Single-voxel downfield MRS was collected using alternately selective or broadband inversion-recovery sequences and spectrally selective 90° E-BURP RF pulse excitation centered at 9.0 ppm with bandwidth = 600 Hz (2.0 ppm). MRS was collected using TIs of 50-2500 ms. We modeled recovery of the longitudinal magnetization of three observable resonances using two models: (1) a three-parameter model accounting for the apparent T1 recovery and (2) a Solomon model explicitly including cross-relaxation effects. RESULTS: Three resonances were observed in human calf muscle at 7 T at 8.0, 8.2, and 8.5 ppm. We found broadband (broad) and selective (sel) inversion recovery T1 = mean ± SD (ms): T1-broad,8.0ppm = 2108.2 ± 664.5, T1-sel,8.0ppm = 753.6 ± 141.0 (p = 0.003); T1-broad,8.2ppm = 2033.5 ± 338.4, T1-sel,8.2ppm = 135.3 ± 35.3 (p < 0.0001); and T1-broad,8.5ppm = 1395.4 ± 75.4, T1-sel,8.5ppm = 107.1 ± 40.0 (p < 0.0001). Using the Solomon model, we found T1 = mean ± SD (ms): T1-8.0ppm = 1595.6 ± 491.1, T1-8.2ppm = 1737.2 ± 963.7, and T1-8.5ppm = 849.8 ± 282.0 (p = 0.04). Post hoc tests corrected for multiple comparisons showed no significant difference in T1 between peaks. The cross-relaxation rate σAB = mean ± SD (Hz) of each peak was σAB,8.0ppm = 0.76 ± 0.20, σAB,8.2ppm = 5.31 ± 2.27, and σAB,8.5ppm = 7.90 ± 2.74 (p < 0.0001); post hoc t-tests revealed the cross-relaxation rate of the 8.0 ppm peak was significantly slower than the peaks at 8.2 ppm (p = 0.0018) and 8.5 ppm (p = 0.0005). CONCLUSION: We found significant differences in effective T1 and cross-relaxation rates of 1 H resonances between 8.0 and 8.5 ppm in the healthy human calf muscle at 7 T.


Assuntos
Músculo Esquelético , Humanos , Espectroscopia de Ressonância Magnética , Músculo Esquelético/diagnóstico por imagem
18.
Osteoarthritis Cartilage ; 31(1): 96-105, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36252943

RESUMO

OBJECTIVE: Evaluate patellofemoral cartilage health, as assessed by quantitative magnetic resonance imaging (qMRI) T2 relaxation times, 24-months after ACL reconstruction (ACLR) and determine if they were associated with patellofemoral contact forces and knee mechanics during gait 3 months after surgery. DESIGN: Thirty individuals completed motion analysis during overground walking at a self-selected speed 3 months after ACLR. An EMG-driven neuromusculoskeletal model was used to determine muscle forces, which were then used in a previously described model to estimate patellofemoral contact forces. Biomechanical variables of interest included peak patellofemoral contact force, peak knee flexion angle and moment, and walking speed. These same participants underwent a sagittal bilateral T2 mapping qMRI scan 24-months after surgery. T2 relaxation times were estimated for both patellar and trochlear cartilage. Paired t-tests were used to compare T2 relaxation times between limbs while Pearson correlations and linear regressions were utilized to assess the association between the biomechanical variables of interest and T2 relaxation times. RESULTS: Prolonged involved limb trochlear T2 relaxation times (vs uninvolved) were present 24-months after surgery, indicating worse cartilage health. No differences were detected in patellar cartilage. Significant negative associations were present within the involved limb for all the biomechanical variables of interest 3 months after ACLR and trochlear T2 relaxation times at 24-months. No associations were found in patellar cartilage or within the uninvolved limb. CONCLUSIONS: Altered involved limb trochlear cartilage health is present 24-months after ACLR and may be related to patellofemoral loading and other walking gait mechanics 3 months after surgery.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Cartilagem Articular , Osteoartrite do Joelho , Humanos , Reconstrução do Ligamento Cruzado Anterior/métodos , Cartilagem Articular/patologia , Osteoartrite do Joelho/patologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Marcha/fisiologia , Lesões do Ligamento Cruzado Anterior/cirurgia , Imageamento por Ressonância Magnética/métodos , Fenômenos Biomecânicos
19.
NMR Biomed ; 36(5): e4873, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36347826

RESUMO

T1 relaxation times of the 14 T1 phantom spheres that make up the standard International Society for Magnetic Resonance in Medicine (ISMRM)/National Institute of Standards and Technology (NIST) system phantom are reported at 7 T. T1 values of six of the 14 T1 spheres at 7 T (with T1 > 270 ms) have been reported previously, but, to the best of our knowledge, not all of the T1s of the 14 T1 spheres at 7 T have been reported before. Given the increasing number of 7-T MRI systems in clinical settings and the increasing need for T1 phantoms that cover a wide range of T1 relaxation times to evaluate rapid T1 mapping techniques at 7 T, it is of high interest to obtain accurate T1 values for all the ISMRM/NIST T1 spheres at 7 T. In this work, T1 relaxation time was measured on a 7-T MRI scanner using an inversion-recovery spin-echo pulse sequence and derived by curve fitting to a signal equation that exhibits insensitivity to B 1 + inhomogeneity. Day-to-day reproducibility was within 0.4% and differences between two different RF coils within 1.5%. T1s of a subset of the 14 spheres were also measured by NMR at 7 T for comparison, and the T1 results were consistent between the MRI and NMR measurements. T1 measurements performed at 3 T on the same 14 spheres using the same sequence and fitting method yielded good agreement (mean percentage difference of -0.4%) with the reference T1 values available from the NIST, reflecting the accuracy of the reported technique despite being without the standard phantom housing. We found that the T1 values of all 14 NiCl2 spheres are consistently lower at 7 T than at 3 T. Although our results were well reproduced, this study represents initial work to quantify the 7-T T1 values of all 14 NIST T1 spheres outside of the standard housing and does not warrant reproducibility of the ISMRM/NIST system phantom as a whole. A future study to assess the T1 values of a version of the ISMRM/NIST system phantom that fits inside typical commercial coils at 7 T will be very helpful. Nonetheless, the details on our acquisition and curve-fitting methods reported here allow the T1 measurements to be reproduced elsewhere. The T1 values of all 14 spheres reported here will be valuable for the development of quantitative MR fingerprinting and rapid T1 mapping for a large variety of research projects, not only in neuroimaging but also in body MRI, musculoskeletal MRI, and gadolinium contrast-enhanced MRI, each of which is concerned with much shortened T1.


Assuntos
Imageamento por Ressonância Magnética , Neuroimagem , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Valores de Referência
20.
NMR Biomed ; : e4947, 2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37021657

RESUMO

MRI's T2 relaxation time is a valuable biomarker for neuromuscular disorders and muscle dystrophies. One of the hallmarks of these pathologies is the infiltration of adipose tissue and a loss of muscle volume. This leads to a mixture of two signal components, from fat and from water, to appear in each imaged voxel, each having a specific T2 relaxation time. In this proof-of-concept work, we present a technique that can separate the signals from water and from fat within each voxel, measure their separate T2 values, and calculate their relative fractions. The echo modulation curve (EMC) algorithm is a dictionary-based technique that offers accurate and reproducible mapping of T2 relaxation times. We present an extension of the EMC algorithm for estimating subvoxel fat and water fractions, alongside the T2 and proton-density values of each component. To facilitate data processing, calf and thigh anatomy were automatically segmented using a fully convolutional neural network and FSLeyes software. The preprocessing included creating two signal dictionaries, for water and for fat, using Bloch simulations of the prospective protocol. Postprocessing included voxelwise fitting for two components, by matching the experimental decay curve to a linear combination of the two simulated dictionaries. Subvoxel fat and water fractions and relaxation times were generated and used to calculate a new quantitative biomarker, termed viable muscle index, and reflecting disease severity. This biomarker indicates the fraction of remaining muscle out of the entire muscle region. The results were compared with those using the conventional Dixon technique, showing high agreement (R = 0.98, p < 0.001). It was concluded that the new extension of the EMC algorithm can be used to quantify abnormal fat infiltration as well as identify early inflammatory processes corresponding to elevation in the T2 value of the water (muscle) component. This new ability may improve the diagnostic accuracy of neuromuscular diseases, help stratification of patients according to disease severity, and offer an efficient tool for tracking disease progression.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA