Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Sensors (Basel) ; 23(13)2023 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-37447749

RESUMO

Impedance cardiography (ICG) is a low-cost, non-invasive technique that enables the clinical assessment of haemodynamic parameters, such as cardiac output and stroke volume (SV). Conventional ICG recordings are taken from the patient's thorax. However, access to ICG vital signs from the upper-arm brachial artery (as an associated surrogate) can enable user-convenient wearable armband sensor devices to provide an attractive option for gathering ICG trend-based indicators of general health, which offers particular advantages in ambulatory long-term monitoring settings. This study considered the upper arm ICG and control Thorax-ICG recordings data from 15 healthy subject cases. A prefiltering stage included a third-order Savitzky-Golay finite impulse response (FIR) filter, which was applied to the raw ICG signals. Then, a multi-stage wavelet-based denoising strategy on a beat-by-beat (BbyB) basis, which was supported by a recursive signal-averaging optimal thresholding adaptation algorithm for Arm-ICG signals, was investigated for robust signal quality enhancement. The performance of the BbyB ICG denoising was evaluated for each case using a 700 ms frame centred on the heartbeat ICG pulse. This frame was extracted from a 600-beat ensemble signal-averaged ICG and was used as the noiseless signal reference vector (gold standard frame). Furthermore, in each subject case, enhanced Arm-ICG and Thorax-ICG above a threshold of correlation of 0.95 with the noiseless vector enabled the analysis of beat inclusion rate (BIR%), yielding an average of 80.9% for Arm-ICG and 100% for Thorax-ICG, and BbyB values of the ICG waveform feature metrics A, B, C and VET accuracy and precision, yielding respective error rates (ER%) of 0.83%, 11.1%, 3.99% and 5.2% for Arm-IG, and 0.41%, 3.82%, 1.66% and 1.25% for Thorax-ICG, respectively. Hence, the functional relationship between ICG metrics within and between the arm and thorax recording modes could be characterised and the linear regression (Arm-ICG vs. Thorax-ICG) trends could be analysed. Overall, it was found in this study that recursive averaging, set with a 36 ICG beats buffer size, was the best Arm-ICG BbyB denoising process, with an average of less than 3.3% in the Arm-ICG time metrics error rate. It was also found that the arm SV versus thorax SV had a linear regression coefficient of determination (R2) of 0.84.


Assuntos
Cardiografia de Impedância , Hemodinâmica , Humanos , Débito Cardíaco/fisiologia , Volume Sistólico/fisiologia , Cardiografia de Impedância/métodos , Hemodinâmica/fisiologia , Monitorização Ambulatorial
2.
Med Res Rev ; 41(4): 2039-2108, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33559917

RESUMO

Zika virus (ZIKV) has emerged as a particularly notorious mosquito-borne flavivirus, which can lead to a devastating congenital syndrome in the fetuses of pregnant mothers (e.g., microcephaly, spasticity, craniofacial disproportion, miscarriage, and ocular abnormalities) and cause the autoimmune disorder Guillain-Barre' syndrome of adults. Due to its severity and rapid dispersal over several continents, ZIKV has been acknowledged to be a global health concern by the World Health Organization. Unfortunately, the ZIKV has recently resurged in India with the potential for devastating effects. Researchers from all around the world have worked tirelessly to develop effective detection strategies and vaccines for the prevention and control of ZIKV infection. In this review, we comprehensively summarize the most recent research into ZIKV, including the structural biology and evolution, historical overview, pathogenesis, symptoms, and transmission. We then focus on the detection strategies for ZIKV, including viral isolation, serological assays, molecular assays, sensing methods, reverse transcription loop mediated isothermal amplification, transcription-mediated amplification technology, reverse transcription strand invasion based amplification, bioplasmonic paper-based device, and reverse transcription isothermal recombinase polymerase amplification. To conclude, we examine the limitations of currently available strategies for the detection of ZIKV, and outline future opportunities and research challenges.


Assuntos
Infecção por Zika virus , Zika virus , Adulto , Animais , Feminino , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Gravidez , Zika virus/genética , Infecção por Zika virus/diagnóstico
3.
Sensors (Basel) ; 21(13)2021 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-34199010

RESUMO

In all ultrasonic material evaluation methods, transducers and sensors play a key role of mechanoelectrical conversion. Their transduction characteristics must be known quantitatively in designing and implementing successful structural health monitoring (SHM) systems. Yet, their calibration and verification have lagged behind most other aspects of SHM system development. This study aims to extend recent advances in quantifying the transmission and receiving sensitivities to normally incident longitudinal waves of ultrasonic transducers and acoustic emission sensors. This paper covers extending the range of detection to lower frequencies, expanding to areal and multiple sensing methods and examining transducer loading effects. Using the refined transmission characteristics, the receiving sensitivities of transducers and sensors were reexamined under the conditions representing their actual usage. Results confirm that the interfacial wave transmission is governed by wave propagation theory and that the receiving sensitivity of resonant acoustic emission sensors peaks at antiresonance.


Assuntos
Transdutores , Ultrassom , Acústica , Calibragem , Monitorização Fisiológica
4.
Sensors (Basel) ; 19(1)2019 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-30621335

RESUMO

In recent years, along with the rapid development of relevant biological fields, there has been a tremendous motivation to combine molecular imprinting technology (MIT) with biosensing. In this situation, bioprobes and biosensors based on molecularly imprinted polymers (MIPs) have emerged as a reliable candidate for a comprehensive range of applications, from biomolecule detection to drug tracking. Unlike their precursors such as classic immunosensors based on antibody binding and natural receptor elements, MIPs create complementary cavities with stronger binding affinity, while their intrinsic artificial polymers facilitate their use in harsh environments. The major objective of this work is to review recent MIP bioprobes and biosensors, especially those used for biomolecules and drugs. In this review, MIP bioprobes and biosensors are categorized by sensing method, including optical sensing, electrochemical sensing, gravimetric sensing and magnetic sensing, respectively. The working mechanism(s) of each sensing method are thoroughly discussed. Moreover, this work aims to present the cutting-edge structures and modifiers offering higher properties and performances, and clearly point out recent efforts dedicated to introduce multi-sensing and multi-functional MIP bioprobes and biosensors applicable to interdisciplinary fields.


Assuntos
Biopolímeros/isolamento & purificação , Técnicas Biossensoriais/tendências , Impressão Molecular/tendências , Polímeros/química , Biopolímeros/química , Humanos , Ligação Proteica
5.
Conserv Biol ; 31(1): 213-220, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27564920

RESUMO

Although remote sensing has been used for >40 years to learn about Earth, use of very high-resolution satellite imagery (VHR) (<1-m resolution) has become more widespread over the past decade for studying wildlife. As image resolution increases, there is a need to understand the capabilities and limitations of this exciting new path in wildlife research. We reviewed studies that used VHR to examine remote populations of wildlife. We then determined characteristics of the landscape and the life history of species that made the studies amenable to use of satellite imagery and developed a list of criteria necessary for appropriate use of VHR in wildlife research. From 14 representative articles, we determined 3 primary criteria that must be met for a system and species to be appropriately studied with VHR: open landscape, target organism's color contrasts with the landscape, and target organism is of detectable size. Habitat association, temporal exclusivity, coloniality, landscape differentiation, and ground truthing increase the utility of VHR for wildlife research. There is an immediate need for VHR imagery in conservation research, particularly in remote areas of developing countries, where research can be difficult. For wildlife researchers interested in but unfamiliar with remote sensing resources and tools, understanding capabilities and current limitations of VHR imagery is critical to its use as a conservation and wildlife research tool.


Assuntos
Animais Selvagens , Conservação dos Recursos Naturais , Imagens de Satélites , Vertebrados , Animais , Ecossistema
6.
Sensors (Basel) ; 12(7): 9635-65, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23012563

RESUMO

Sensing technology has been widely investigated and utilized for gas detection. Due to the different applicability and inherent limitations of different gas sensing technologies, researchers have been working on different scenarios with enhanced gas sensor calibration. This paper reviews the descriptions, evaluation, comparison and recent developments in existing gas sensing technologies. A classification of sensing technologies is given, based on the variation of electrical and other properties. Detailed introduction to sensing methods based on electrical variation is discussed through further classification according to sensing materials, including metal oxide semiconductors, polymers, carbon nanotubes, and moisture absorbing materials. Methods based on other kinds of variations such as optical, calorimetric, acoustic and gas-chromatographic, are presented in a general way. Several suggestions related to future development are also discussed. Furthermore, this paper focuses on sensitivity and selectivity for performance indicators to compare different sensing technologies, analyzes the factors that influence these two indicators, and lists several corresponding improved approaches.

7.
Artigo em Inglês | MEDLINE | ID: mdl-36360992

RESUMO

Nowadays, water pollution has become a global issue affecting most countries in the world. Water quality should be monitored to alert authorities on water pollution, so that action can be taken quickly. The objective of the review is to study various conventional and modern methods of monitoring water quality to identify the strengths and weaknesses of the methods. The methods include the Internet of Things (IoT), virtual sensing, cyber-physical system (CPS), and optical techniques. In this review, water quality monitoring systems and process control in several countries, such as New Zealand, China, Serbia, Bangladesh, Malaysia, and India, are discussed. Conventional and modern methods are compared in terms of parameters, complexity, and reliability. Recent methods of water quality monitoring techniques are also reviewed to study any loopholes in modern methods. We found that CPS is suitable for monitoring water quality due to a good combination of physical and computational algorithms. Its embedded sensors, processors, and actuators can be designed to detect and interact with environments. We believe that conventional methods are costly and complex, whereas modern methods are also expensive but simpler with real-time detection. Traditional approaches are more time-consuming and expensive due to the high maintenance of laboratory facilities, involve chemical materials, and are inefficient for on-site monitoring applications. Apart from that, previous monitoring methods have issues in achieving a reliable measurement of water quality parameters in real time. There are still limitations in instruments for detecting pollutants and producing valuable information on water quality. Thus, the review is important in order to compare previous methods and to improve current water quality assessments in terms of reliability and cost-effectiveness.


Assuntos
Internet das Coisas , Qualidade da Água , Reprodutibilidade dos Testes , Poluição da Água , Computadores
8.
Foods ; 11(9)2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35564074

RESUMO

Formaldehyde, the simplest molecule of the aldehyde group, is a gaseous compound at room temperature and pressure, is colorless, and has a strong, pungent odor. It is soluble in water, ethanol, and diethyl ether and is used in solution or polymerized form. Its maximum daily dosage established by the EPA is 0.2 µg g-1 of body weight whereas that established by the WHO is between 1.5 and 14 mg g-1: it is in category 1A of carcinogens by IARC. From an analytical point of view, formaldehyde is traditionally analyzed by HPLC with UV-Vis detection. Nowadays, the need to analyze this compound quickly and in situ is increasing. This work proposes a critical review of methods for analyzing formaldehyde in food using sensing methods. A search carried out on the Scopus database documented more than 50 papers published in the last 5 years. The increase in interest in the recognition of the presence of formaldehyde in food has occurred in recent years, above all due to an awareness of the damage it can cause to human health. This paper focuses on some new sensors by analyzing their performance and comparing them with various no-sensing methods but focusing on the determination of formaldehyde in food products. The sensors reported are of various types, but they all share a good LOD, good accuracy, and a reduced analysis time. Some of them are also biodegradable and others have a very low cost, many are portable and easy to use, therefore usable for the recognition of food adulterations on site.

9.
Int J Food Microbiol ; 343: 109094, 2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33621832

RESUMO

Anisakid nematode larvae (NL) in fish products comprise a risk to human health and, if visible, lead to the rejection of these products by consumers. Therefore, great efforts are being made for the identification of these anisakid larvae to estimate the potential consumer health risk as well as to develop effective detection methods in order to prevent the introduction of heavily infected fish products into the market. The tasks of national reference laboratories include the improvement of detection methods and to promote their further development. As a prerequisite for improved detection, it is important to understand the structural properties of anisakid NL and compounds produced during host-parasite interactions. This review provides an overview of the intrinsic properties of anisakid NL and reports the latest detection methods in published literature. First, in order to define the potentially interesting intrinsic properties of anisakid nematodes for their detection, anatomy and compounds involved in host-parasite interactions are summarised. These can be used for various detection approaches, such as in the medical field or for allergen detection in fish products. In addition, fluorescence characteristics and their use as both established and promising candidates for detection methods, especially in the field of optical sensing technologies, are presented. Finally, different detection and identification methods applied by the fish processing industries and by control laboratories are listed. The review intends to highlight trends and provide suggestions for the development of improved detection and identification methods of anisakid NL in fish products.


Assuntos
Anisakis/isolamento & purificação , Produtos Pesqueiros/parasitologia , Microbiologia de Alimentos , Animais , Anisaquíase/parasitologia , Anisaquíase/prevenção & controle , Anisakis/anatomia & histologia , Anisakis/química , Produtos Pesqueiros/análise , Fluorescência , Indústria de Processamento de Alimentos , Interações Hospedeiro-Parasita , Humanos , Larva/anatomia & histologia , Larva/química
10.
Biosens Bioelectron ; 143: 111662, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31491726

RESUMO

Traditional analytical techniques face many limitations such as time-consuming process, complicated sample preparation, high consumption of reagents and need for expensive equipment. So, it is important that simple, rapid and sensitive detection methods are introduced. Nucleic acids-based assays, particularly aptamers, have a great impact on modern life sciences for biological analysis and target detection. Aptamer-based biosensors with unique recognition properties including high specificity and affinity, rapid response and simple fabrication have attracted much attention. It is believed that two- and three-dimensional structures, sometimes referred to as DNA origami, using DNA aptamers can show more selective binding affinity and better stability over other nucleic acids forms. In this review, we will focus on recent advances in the development and uses of electrochemical and optical DNA origami-based aptasensors to supply readers with a comprehensive understanding of their improvements. Also, the challenges and awards of these approaches are discussed.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais , DNA/isolamento & purificação , Técnicas Eletroquímicas , Aptâmeros de Nucleotídeos/genética , Colorimetria , DNA/química , Humanos , Conformação de Ácido Nucleico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA