Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Pediatr Diabetes ; 22(3): 495-502, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33289242

RESUMO

BACKGROUND: Data on the use of Control-IQ, the latest FDA-approved automated insulin delivery (AID) system for people with T1D 6 years of age or older is still scarce, particularly regarding nonglycemic outcomes. Children with T1D and their parents are at higher risk for sleep disturbances. This study assesses sleep, psycho-behavioral and glycemic outcomes of AID compared to sensor-augmented pump therapy (SAP) therapy in young children with T1D and their parents. METHODS: Thirteen parents and their young children (ages 7-10) on insulin pump therapy were enrolled. Children completed an initial 4-week study with SAP using their own pump and a study CGM followed by a 4-week phase of AID. Sleep outcomes for parents and children were evaluated through actigraphy watches. Several questionnaires were administered at baseline and at the end of each study phase. CGM data were used to assess glycemic outcomes. RESULTS: Actigraphy data did not show any significant change from SAP to AID, except a reduction of number of parental awakenings during the night (p = 0.036). Parents reported statistically significant improvements in Pittsburgh Sleep Quality Index total score (p = 0.009), Hypoglycemia Fear Survey total score (p = 0.011), diabetes-related distress (p = 0.032), and depression (p = 0.023). While on AID, time in range (70-180 mg/dL) significantly increased compared to SAP (p < 0.001), accompanied by a reduction in hyperglycemia (p = 0.001). CONCLUSIONS: These results suggest that use of AID has a positive impact on glycemic outcomes in young children as well as sleep and diabetes-specific quality of life outcomes in their parents.


Assuntos
Diabetes Mellitus Tipo 1/psicologia , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pais/psicologia , Qualidade do Sono , Adulto , Automonitorização da Glicemia , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Inquéritos e Questionários
2.
Diabetol Int ; 11(2): 97-104, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32206479

RESUMO

AIMS/INTRODUCTION: The predictive low glucose management (PLGM) system was introduced in March 2018 in Japan. Although there are some reports demonstrating the benefit of PLGM in preventing hypoglycemia, no data are currently available in Japanese patients with type 1 diabetes mellitus (T1DM). The aim of the present study is to evaluate the effect of PLGM with sensor-augmented pump therapy in the prevention of hypoglycemia in Japanese patients. MATERIALS AND METHODS: We included 16 patients with T1DM who used the MiniMed®640G system after switching from the MiniMed®620G system. We retrospectively analysed the data of the continuous glucose monitoring system in 1 month after switching to MiniMed®640G. RESULTS: The area under the curve (AUC) of hypoglycemia of < 70 mg/dL was lowered from 0.42 ± 0.43 mg/dL day to 0.18 ± 0.18 mg/dL day (P = 0.012). Correspondingly, the duration of severe hypoglycemia (< 54 mg/dL) was reduced significantly from 15.3 ± 21.7 min/day to 4.8 ± 6.9 min/day (P = 0.019). The duration of hypoglycemia was reduced, but the reduction was not significant. Regarding the AUC for hyperglycemia > 180 mg/dL and the duration of hyperglycemia did not change. With the PLGM function, 79.3% of the predicted hypoglycemic events were avoided. CONCLUSIONS: The hypoglycemia avoidance rate was comparable to those in previous reports. In addition, we demonstrated that PLGM can markedly suppress severe hypoglycemia without deteriorating glycemic control in Japanese T1DM patients. It is necessary to further investigate the effective use of the PLGM feature such as establishing a lower limit and the timing of resumption.

3.
Diabetes Technol Ther ; 19(3): 173-182, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28099035

RESUMO

BACKGROUND: A sensor-augmented insulin pump (SAP) using the MiniMed® 640G system with SmartGuard™ technology allows an automatic stop of insulin delivery based on prediction of low glucose levels. Since pediatric patients are particularly prone to hypoglycemia, this device may offer additional protection beyond conventional sensor-augmented therapy. METHODS: This prospective, pediatric multicenter user evaluation assessed 6 weeks of SAP with SmartGuard (threshold setting for hypoglycemia: 70 mg/dL) compared to a preceding period of 2 weeks with SAP only. The primary outcome was the potential reduction in the frequency of hypoglycemic episodes and hypoglycemic intensity (area under the curve [AUC] and time <70 mg/dL). RESULTS: The study included 24 patients with at least 3 months of insulin pump use (average age: 11.6 ± 5.1 years, 15 female, average type 1 diabetes duration: 7.5 ± 4.2 years, mean ± SD) who had on average 3.2 ± 1.0 predictive suspensions/patient/day. The mean sensor glucose minimum during suspension was 78 ± 6 mg/dL and the average suspension time was 155 ± 47 min/day. Use of SmartGuard in patients treated as per the protocol (n = 18) reduced the number of instances in which the glucose level was <70 mg/dL (1.02 ± 0.52 to 0.72 ± 0.36; P = 0.027), as well as AUC <70 mg/dL (0.76 ± 0.73 to 0.38 ± 0.24; P = 0.027) and the time/day the level fell below 70 mg/dL (73 ± 56 to 31 ± 22 min). The reduction of hypoglycemia was not associated with a significant change in mean glucose concentration (171 ± 26 to 180 ± 19 mg/dL, P = 0.111) and HbA1c (7.5% ± 0.5% to 7.6% ± 0.7%, (P = 0.329). Manual resumption of insulin delivery followed by carbohydrate intake resulted in significantly higher glucose levels 1 h after suspension compared to SmartGuard suspensions with automatic resume (190.8 ± 26.5 vs. 138.7 ± 10.3 mg/dL; P < 0.001). CONCLUSIONS: SmartGuard technology significantly reduced the risk for hypoglycemia in pediatric type 1 diabetes patients without increasing HbA1c. Patients must be educated that when using combining predictive low-glucose insulin suspension technology, extra carbohydrate intake in response to an alarm combined with manual resumption is likely to cause rebound hyperglycemia. The best results were achieved when the user did not interfere with pump operation.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Adolescente , Algoritmos , Criança , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Hipoglicemia/sangue , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Insulina/administração & dosagem , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA