Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 786
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Small ; 20(28): e2311036, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38342584

RESUMO

Wearable devices play an indispensable role in modern life, and the human body contains multiple wasted energies available for wearable devices. This study proposes a self-sensing and self-powered wearable system (SS-WS) based on scavenging waist motion energy and knee negative energy. The proposed SS-WS consists of a three-degree-of-freedom triboelectric nanogenerator (TDF-TENG) and a negative energy harvester (NEH). The TDF-TENG is driven by waist motion energy and the generated triboelectric signals are processed by deep learning for recognizing the human motion. The triboelectric signals generated by TDF-TENG can accurately recognize the motion state after processing based on Gate Recurrent Unit deep learning model. With double frequency up-conversion, the NEH recovers knee negative energy generation for powering wearable devices. A model wearing the single energy harvester can generate the power of 27.01 mW when the movement speed is 8 km h-1, and the power density of NEH reaches 0.3 W kg-1 at an external excitation condition of 3 Hz. Experiments and analysis prove that the proposed SS-WS can realize self-sensing and effectively power wearable devices.


Assuntos
Fontes de Energia Elétrica , Dispositivos Eletrônicos Vestíveis , Humanos , Movimento (Física) , Movimento
2.
Stat Med ; 43(17): 3227-3238, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816901

RESUMO

The prevalence of e-cigarette use among young adults in the USA is high (14%). Although the majority of users plan to quit vaping, the motivation to make a quit attempt is low and available support during a quit attempt is limited. Using wearable sensors to collect physiological data (eg, heart rate) holds promise for capturing the right timing to deliver intervention messages. This study aims to fill the current knowledge gap by proposing statistical methods to (1) de-noise beat-to-beat interval (BBI) data from smartwatches worn by 12 young adult regular e-cigarette users for 7 days; and (2) summarize the de-noised data by event and control segments. We also conducted a comprehensive review of conventional methods for summarizing heart rate variability (HRV) and compared their performance with the proposed method. The results show that the proposed singular spectrum analysis (SSA) can effectively de-noise the highly variable BBI data, as well as quantify the proportion of total variation extracted. Compared to existing HRV methods, the proposed second order polynomial model yields the highest area under the curve (AUC) value of 0.76 and offers better interpretability. The findings also indicate that the average heart rate before vaping is higher and there is an increasing trend in the heart rate before the vaping event. Importantly, the development of increasing heart rate observed in this study implies that there may be time to intervene as this physiological signal emerges. This finding, if replicated in a larger scale study, may inform optimal timings for delivering messages in future intervention.


Assuntos
Frequência Cardíaca , Vaping , Dispositivos Eletrônicos Vestíveis , Humanos , Frequência Cardíaca/fisiologia , Adulto Jovem , Masculino , Feminino , Sistemas Eletrônicos de Liberação de Nicotina/estatística & dados numéricos , Adulto , Modelos Estatísticos
3.
J Surg Res ; 295: 853-861, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38052697

RESUMO

INTRODUCTION: Markers of postoperative recovery in pediatric patients are difficult for parents to evaluate after hospital discharge, who use subjective proxies to assess recovery and the onset of complications. Consumer-grade wearable devices (e.g., Fitbit) generate objective recovery data in near real time and thus may provide an opportunity to remotely monitor postoperative patients and identify complications beyond the initial hospitalization. The aim of this study was to use daily step counts from a Fitbit to compare recovery in patients with complications to those without complications after undergoing appendectomy for complicated appendicitis. METHODS: Children ages 3-17 years old undergoing laparoscopic appendectomy for complicated appendicitis were recruited. Patients wore a Fitbit device for 21 d after operation. After collection, patient data were included in the analysis if minimum wear-time criteria were achieved. Postoperative complications were identified through chart review, and step count trajectories for patients recovering with and without complications were compared. Additionally, to account for the patients experiencing a complication on different postoperative days, median daily step count for pre- and post-complication were analyzed. RESULTS: Eighty-six patients with complicated appendicitis were enrolled in the study, and fourteen children developed a postoperative complication. Three patients were excluded because they did not meet the minimum wear time requirements. Complications were divided into abscesses (n = 7, 64%), surgical site infections (n = 2, 18%), and other, which included small bowel obstruction and Clostridioides difficile infection (n = 2, 18%). Patients presented with a complication on mean postoperative day 8, while deviation from the normative recovery trajectory was evident 4 d prior. When compared to children with normative recovery, the patients with surgical complications experienced a slower increase in step count postoperatively, but the recovery trajectory was specific to each complication type. When corrected for day of presentation with complication, step count remained low prior to the discovery of the complication and increased after treatment resembling the normative recovery trajectory. CONCLUSIONS: This study profiled variations from the normative recovery trajectory in patients with complication after appendectomy for complicated appendicitis, with distinct trajectory patterns by complication type. Our findings have potentially profound clinical implications for monitoring pediatric patients postoperatively, particularly in the outpatient setting, thus providing objective data for potentially earlier identification of complications after hospital discharge.


Assuntos
Apendicite , Laparoscopia , Dispositivos Eletrônicos Vestíveis , Humanos , Criança , Pré-Escolar , Adolescente , Apendicectomia/efeitos adversos , Apendicite/cirurgia , Apendicite/complicações , Laparoscopia/efeitos adversos , Hospitalização , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Tempo de Internação
4.
Support Care Cancer ; 32(3): 188, 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38400942

RESUMO

PURPOSE: Pediatric patients with cancer often develop chemotherapy-induced fever in neutropenia (FN), requiring emergency broad-spectrum antibiotics. Continuous temperature monitoring can lead to earlier FN detection and therapy with improved outcomes. We aimed to compare the feasibility of continuous core temperature monitoring with timely data availability between two wearable devices (WDs) in pediatric oncology patients undergoing chemotherapy. METHODS: In this prospective observational two-center study, 20 patients (median age: 8 years) undergoing chemotherapy simultaneously wore two WDs (CORE®, Everion®) for 14 days. The predefined goal was core temperature recorded in sufficient quality and available within ≤ 30 min during ≥ 18/24 h for ≥ 7/14 days in more than 15 patients. RESULTS: More patients reached the goal with CORE® (n = 13) versus Everion® (n = 3) (difference, 50% p < 0.001). After correcting for the transmission bottleneck caused by two WDs transmitting via one gateway, these numbers increased (n = 15 versus n = 14; difference, 5%; p = 0.69). CORE® measurements corresponded better to ear temperatures (n = 528; mean bias, - 0.07 °C; mean absolute difference, 0.35 °C) than Everion® measurements (n = 532; - 1.06 °C; 1.10 °C). Acceptance rates for the WDs were 95% for CORE® and 89% for Everion®. CONCLUSION: The CORE® fulfilled the predefined feasibility criterion (15 of 20 patients) after correction for transmission bottleneck, and the Everion® nearly fulfilled it. Continuous core temperature recording of good quality and with timely data availability was feasible from preschool to adolescent patients undergoing chemotherapy for cancer. These results encourage the design of randomized controlled trials on continuously monitored core temperature in pediatric patients. CLINICALTRIALS: gov (NCT04914702) on June 7, 2021.


Assuntos
Neoplasias , Dispositivos Eletrônicos Vestíveis , Pré-Escolar , Adolescente , Humanos , Criança , Temperatura , Temperatura Corporal , Neoplasias/tratamento farmacológico , Estudos Prospectivos
5.
Clin Trials ; : 17407745241230287, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38486348

RESUMO

BACKGROUND/AIMS: Information regarding the use of wearable devices in clinical research, including disease areas, intervention techniques, trends in device types, and sample size targets, remains elusive. Therefore, we conducted a comprehensive review of clinical research trends related to wristband wearable devices in research planning and examined their applications in clinical investigations. METHODS: As this study identified trends in the adoption of wearable devices during the planning phase of clinical research, including specific disease areas and targeted number of intervention cases, we searched ClinicalTrials.gov-a prominent platform for registering and disseminating clinical research. Since wrist-worn devices represent a large share of the market, we focused on wrist-worn devices and selected the most representative models among them. The main analysis focused on major wearable devices to facilitate data analysis and interpretation, but other wearables were also surveyed for reference. We searched ClinicalTrials.gov with the keywords "ActiGraph,""Apple Watch,""Empatica,""Fitbit,""Garmin," and "wearable devices" to obtain studies published up to 21 August 2022. This initial search yielded 3214 studies. After excluding duplicate National Clinical Trial studies (the overlap was permissible among different device types except for wearable devices), our analysis focused on 2930 studies, including simple, time-series, and type-specific assessments of various variables. RESULTS: Overall, an increasing number of clinical studies have incorporated wearable devices since 2012. While ActiGraph and Fitbit initially dominated this landscape, the use of other devices has steadily increased, constituting approximately 10% of the total after 2015. Observational studies outnumbered intervention studies, with behavioral and device-based interventions being particularly prevalent. Regarding disease types, cancer and cardiovascular diseases accounted for approximately 20% of the total. Notably, 114 studies adopted multiple devices simultaneously within the context of their clinical investigations. CONCLUSIONS: Our findings revealed that the utilization of wearable devices for data collection and behavioral interventions in various disease areas has been increasing over time since 2012. The increase in the number of studies over the past 3 years has been particularly significant, suggesting that this trend will continue to accelerate in the future. Devices and their evaluation methods that have undergone thorough validation, confirmed their accuracy, and adhered to established legal regulations will likely assume a pivotal role in evaluations, allowing for remote clinical trials. Moreover, behavioral intervention therapy utilizing apps is becoming more extensive, and we expect to see more examples that will lead to their approval as programmed medical devices in the future.

6.
Am J Emerg Med ; 79: 25-32, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38330880

RESUMO

BACKGROUND: Wearable devices, particularly smartwatches like the Apple Watch (AW), can record important cardiac information, such as single­lead electrocardiograms (ECGs). Although they are increasingly used to detect conditions such as atrial fibrillation (AF), research on their effectiveness in detecting a wider range of dysrhythmias and abnormal ECG findings remains limited. The primary objective of this study is to evaluate the accuracy of the AW in detecting various cardiac rhythms by comparing it with standard ECG's lead-I. METHODS: This single-center prospective observational study was conducted in a tertiary care emergency department (ED) between 1.10.2023 and 31.10.2023. The study population consisted of all patients assessed in the critical care areas of the ED, all of whom underwent standard 12­lead ECGs for various clinical reasons. Participants in the study were included consecutively. An AW was attached to patients' wrists and an ECG lead-I printout was obtained. Heart rate, rhythm and abnormal findings were evaluated and compared with the lead-I of standard ECG. Two emergency medicine specialists performed the ECG evaluations. Rhythms were categorized as normal sinus rhythm and abnormal rhythms, while ECG findings were categorized as the presence or absence of abnormal findings. AW and 12­lead ECG outputs were compared using the McNemar test. Predictive performance analyses were also performed for subgroups. Bland-Altman analysis using absolute mean differences and concordance correlation coefficients was used to assess the level of heart rate agreement between devices. RESULTS: The study was carried out on 721 patients. When analyzing ECG rhythms and abnormal findings in lead-I, the effectiveness of AW in distinguishing between normal and abnormal rhythms was similar to standard ECGs (p = 0.52). However, there was a significant difference between AW and standard ECGs in identifying abnormal findings in lead-I (p < 0.05). Using Bland-Altman analysis for heart rate assessment, the absolute mean difference for heart rate was 0.81 ± 6.12 bpm (r = 0.94). There was strong agreement in 658 out of 700 (94%) heart rate measurements. CONCLUSION: Our study indicates that the AW has the potential to detect cardiac rhythms beyond AF. ECG tracings obtained from the AW may help evaluate cardiac rhythms prior to the patient's arrival in the ED. However, further research with a larger patient cohort is essential, especially for specific diagnoses.


Assuntos
Fibrilação Atrial , Dispositivos Eletrônicos Vestíveis , Humanos , Eletrocardiografia , Fibrilação Atrial/diagnóstico , Frequência Cardíaca/fisiologia , Estudos Prospectivos
7.
J Med Internet Res ; 26: e46098, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512332

RESUMO

BACKGROUND: Wearable electrocardiogram (ECG) monitoring devices are used worldwide. However, data on the diagnostic yield of an adhesive single-lead ECG patch (SEP) to detect premature ventricular complex (PVC) and the optimal duration of wearing an SEP for PVC burden assessment are limited. OBJECTIVE: We aimed to validate the diagnostic yield of an SEP (mobiCARE MC-100, Seers Technology) for PVC detection and evaluate the PVC burden variation recorded by the SEP over a 3-day monitoring period. METHODS: This is a prospective study of patients with documented PVC on a 12-lead ECG. Patients underwent simultaneous ECG monitoring with the 24-hour Holter monitor and SEP on the first day. On the subsequent second and third days, ECG monitoring was continued using only SEP, and a 3-day extended monitoring was completed. The diagnostic yield of SEP for PVC detection was evaluated by comparison with the results obtained on the first day of Holter monitoring. The PVC burden monitored by SEP for 3 days was used to assess the daily and 6-hour PVC burden variations. The number of patients additionally identified to reach PVC thresholds of 10%, 15%, and 20% during the 3-day extended monitoring by SEP and the clinical factors associated with the higher PVC burden variations were explored. RESULTS: The recruited data of 134 monitored patients (mean age, 54.6 years; males, 45/134, 33.6%) were analyzed. The median daily PVC burden of these patients was 2.4% (IQR 0.2%-10.9%), as measured by the Holter monitor, and 3.3% (IQR 0.3%-11.7%), as measured in the 3-day monitoring by SEP. The daily PVC burden detected on the first day of SEP was in agreement with that of the Holter monitor: the mean difference was -0.07%, with 95% limits of agreement of -1.44% to 1.30%. A higher PVC burden on the first day was correlated with a higher daily (R2=0.34) and 6-hour burden variation (R2=0.48). Three-day monitoring by SEP identified 29% (12/42), 18% (10/56), and 7% (4/60) more patients reaching 10%, 15%, and 20% of daily PVC burden, respectively. Younger age was additionally associated with the identification of clinically significant PVC burden during the extended monitoring period (P=.02). CONCLUSIONS: We found that the mobiCARE MC-100 SEP accurately detects PVC with comparable diagnostic yield to the 24-hour Holter monitor. Performing 3-day PVC monitoring with SEP, especially among younger patients, may offer a pragmatic alternative for identifying more individuals exceeding the clinically significant PVC burden threshold.


Assuntos
Complexos Ventriculares Prematuros , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Tecnologia
8.
J Korean Med Sci ; 39(9): e94, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38469966

RESUMO

BACKGROUND: To evaluate the therapeutic effectiveness and safety of a neurofeedback wearable device for stress reduction. METHODS: A randomized, double-blind, controlled study was designed. Participants had psychological stress with depression or sleep disturbances. They practiced either neurofeedback-assisted meditation (n = 20; female, 15 [75.0%]; age, 49.40 ± 11.76 years) or neurofeedback non-assisted meditation (n = 18; female, 11 [61.1%]; age, 48.67 ± 12.90 years) for 12 minutes twice a day for two weeks. Outcome variables were self-reported questionnaires, including the Korean version of the Perceived Stress Scale, Beck Depression Inventory-II, Insomnia Severity Index, Pittsburgh Sleep Quality Index, and State Trait Anxiety Index, quantitative electroencephalography (qEEG), and blood tests. Satisfaction with device use was measured at the final visit. RESULTS: The experimental group had a significant change in PSS score after two weeks of intervention compared with the control group (6.45 ± 0.95 vs. 3.00 ± 5.54, P = 0.037). State anxiety tended to have a greater effect in the experimental group than in the control group (P = 0.078). Depressive mood and sleep also improved in each group, with no significant difference between the two groups. There were no significant differences in stress-related physiological parameters, such as stress hormones or qEEG, between the two groups. Subjective device satisfaction was significantly higher in the experimental group than in the control group (P = 0.008). CONCLUSION: Neurofeedback-assisted meditation using a wearable device can help improve subjective stress reduction compared with non-assisted meditation. These results support neurofeedback as an effective adjunct to meditation for relieving stress. TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0007413.


Assuntos
Meditação , Neurorretroalimentação , Testes Psicológicos , Autorrelato , Dispositivos Eletrônicos Vestíveis , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Método Duplo-Cego , Meditação/métodos , Meditação/psicologia , Estresse Psicológico/terapia , Estresse Psicológico/psicologia , Masculino
9.
BMC Med Inform Decis Mak ; 24(1): 71, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475812

RESUMO

BACKGROUND: Wearable devices have the advantage of always being with individuals, enabling easy detection of their movements. Smart clothing can provide feedback to family caregivers of older adults with disabilities who require in-home care. METHODS: This study describes the process of setting up a smart technology-assisted (STA) home-nursing care program, the difficulties encountered, and strategies applied to improve the program. The STA program utilized a smart-vest, designed specifically for older persons with dementia or recovering from hip-fracture surgery. The smart-vest facilitated nurses' and family caregivers' detection of a care receiver's movements via a remote-monitoring system. Movements included getting up at night, time spent in the bathroom, duration of daytime immobility, leaving the house, and daily activity. Twelve caregivers of older adults and their care receiver participated; care receivers included persons recovering from hip fracture (n = 5) and persons living with dementia (n = 7). Data about installation of the individual STA in-home systems, monitoring, and technical difficulties encountered were obtained from researchers' reports. Qualitative data about the caregivers' and care receivers' use of the system were obtained from homecare nurses' reports, which were explored with thematic analysis. RESULTS: Compiled reports from the research team identified three areas of difficulty with the system: incompatibility with the home environment, which caused extra hours of manpower and added to the cost of set-up and maintenance; interruptions in data transmissions, due to system malfunctions; and inaccuracies in data transmissions, due to sensors on the smart-vest. These difficulties contributed to frustration experienced by caregivers and care receivers. CONCLUSIONS: The difficulties encountered impeded implementation of the STA home nursing care. Each of these difficulties had their own unique problems and strategies to resolve them. Our findings can provide a reference for future implementation of similar smart-home systems, which could facilitate ease-of-use for family caregivers.


Assuntos
Demência , Fraturas do Quadril , Serviços de Assistência Domiciliar , Humanos , Idoso , Idoso de 80 Anos ou mais , Cuidadores , Assistência Domiciliar , Vestuário
10.
J Neuroeng Rehabil ; 21(1): 110, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926876

RESUMO

INTRODUCTION: People with Parkinson's Disease (PD) show abnormal gait patterns compromising their independence and quality of life. Among all gait alterations due to PD, reduced step length, increased cadence, and decreased ground-reaction force during the loading response and push-off phases are the most common. Wearable biofeedback technologies offer the possibility to provide correlated single or multi-modal stimuli associated with specific gait events or gait performance, hence promoting subjects' awareness of their gait disturbances. Moreover, the portability and applicability in clinical and home settings for gait rehabilitation increase the efficiency in the management of PD. The Wearable Vibrotactile Bidirectional Interface (BI) is a biofeedback device designed to extract gait features in real-time and deliver a customized vibrotactile stimulus at the waist of PD subjects synchronously with specific gait phases. The aims of this study were to measure the effect of the BI on gait parameters usually compromised by the typical bradykinetic gait and to assess its usability and safety in clinical practice. METHODS: In this case series, seven subjects (age: 70.4 ± 8.1 years; H&Y: 2.7 ± 0.3) used the BI and performed a test on a 10-meter walkway (10mWT) and a two-minute walk test (2MWT) as pre-training (Pre-trn) and post-training (Post-trn) assessments. Gait tests were executed in random order with (Bf) and without (No-Bf) the activation of the biofeedback stimulus. All subjects performed three training sessions of 40 min to familiarize themselves with the BI during walking activities. A descriptive analysis of gait parameters (i.e., gait speed, step length, cadence, walking distance, double-support phase) was carried out. The 2-sided Wilcoxon sign-test was used to assess differences between Bf and No-Bf assessments (p < 0.05). RESULTS: After training subjects improved gait speed (Pre-trn_No-Bf: 0.72(0.59,0.72) m/sec; Post-trn_Bf: 0.95(0.69,0.98) m/sec; p = 0.043) and step length (Pre-trn_No-Bf: 0.87(0.81,0.96) meters; Post-trn_Bf: 1.05(0.96,1.14) meters; p = 0.023) using the biofeedback during the 10mWT. Similarly, subjects' walking distance improved (Pre-trn_No-Bf: 97.5 (80.3,110.8) meters; Post-trn_Bf: 118.5(99.3,129.3) meters; p = 0.028) and the duration of the double-support phase decreased (Pre-trn_No-Bf: 29.7(26.8,31.7) %; Post-trn_Bf: 27.2(24.6,28.7) %; p = 0.018) during the 2MWT. An immediate effect of the BI was detected in cadence (Pre-trn_No-Bf: 108(103.8,116.7) step/min; Pre-trn_Bf: 101.4(96.3,111.4) step/min; p = 0.028) at Pre-trn, and in walking distance at Post-trn (Post-trn_No-Bf: 112.5(97.5,124.5) meters; Post-trn_Bf: 118.5(99.3,129.3) meters; p = 0.043). SUS scores were 77.5 in five subjects and 80.3 in two subjects. In terms of safety, all subjects completed the protocol without any adverse events. CONCLUSION: The BI seems to be usable and safe for PD users. Temporal gait parameters have been measured during clinical walking tests providing detailed outcomes. A short period of training with the BI suggests improvements in the gait patterns of people with PD. This research serves as preliminary support for future integration of the BI as an instrument for clinical assessment and rehabilitation in people with PD, both in hospital and remote environments. TRIAL REGISTRATION: The study protocol was registered (DGDMF.VI/P/I.5.i.m.2/2019/1297) and approved by the General Directorate of Medical Devices and Pharmaceutical Service of the Italian Ministry of Health and by the ethics committee of the Lombardy region (Milan, Italy).


Assuntos
Biorretroalimentação Psicológica , Transtornos Neurológicos da Marcha , Doença de Parkinson , Dispositivos Eletrônicos Vestíveis , Humanos , Doença de Parkinson/reabilitação , Doença de Parkinson/complicações , Doença de Parkinson/fisiopatologia , Idoso , Masculino , Biorretroalimentação Psicológica/instrumentação , Biorretroalimentação Psicológica/métodos , Feminino , Transtornos Neurológicos da Marcha/reabilitação , Transtornos Neurológicos da Marcha/etiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Pessoa de Meia-Idade , Marcha/fisiologia
11.
J Neuroeng Rehabil ; 21(1): 45, 2024 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570841

RESUMO

BACKGROUND: Knee osteoarthritis (KOA) is an irreversible degenerative disease that characterized by pain and abnormal gait. Radiography is typically used to detect KOA but has limitations. This study aimed to identify changes in plantar pressure that are associated with radiological knee osteoarthritis (ROA) and to validate them using machine learning algorithms. METHODS: This study included 92 participants with variable degrees of KOA. A modified Kellgren-Lawrence scale was used to classify participants into non-ROA and ROA groups. The total feature set included 210 dynamic plantar pressure features captured by a wearable in-shoe system as well as age, gender, height, weight, and body mass index. Filter and wrapper methods identified the optimal features, which were used to train five types of machine learning classification models for further validation: k-nearest neighbors (KNN), support vector machine (SVM), random forest (RF), AdaBoost, and eXtreme gradient boosting (XGBoost). RESULTS: Age, the standard deviation (SD) of the peak plantar pressure under the left lateral heel (f_L8PPP_std), the SD of the right second peak pressure (f_Rpeak2_std), and the SD of the variation in the anteroposterior displacement of center of pressure (COP) in the right foot (f_RYcopstd_std) were most associated with ROA. The RF model with an accuracy of 82.61% and F1 score of 0.8000 had the best generalization ability. CONCLUSION: Changes in dynamic plantar pressure are promising mechanical biomarkers that distinguish between non-ROA and ROA. Combining a wearable in-shoe system with machine learning enables dynamic monitoring of KOA, which could help guide treatment plans.


Assuntos
Osteoartrite do Joelho , Dispositivos Eletrônicos Vestíveis , Humanos , Osteoartrite do Joelho/diagnóstico por imagem , Radiografia , Marcha , Aprendizado de Máquina
12.
IEEE Sens J ; 24(5): 6888-6897, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38476583

RESUMO

We developed an ankle-worn gait monitoring system for tracking gait parameters, including length, width, and height. The system utilizes ankle bracelets equipped with wide-angle infrared (IR) stereo cameras tasked with monitoring a marker on the opposing ankle. A computer vision algorithm we have also developed processes the imaged marker positions to estimate the length, width, and height of the person's gait. Through testing on multiple participants, the prototype of the proposed gait monitoring system exhibited notable performance, achieving an average accuracy of 96.52%, 94.46%, and 95.29% for gait length, width, and height measurements, respectively, despite distorted wide-angle images. The OptiGait system offers a cost-effective and user-friendly alternative compared to existing gait parameter sensing systems, delivering comparable accuracy in measuring gait length and width. Notably, the system demonstrates a novel capability in measuring gait height, a feature not previously reported in the literature.

13.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544279

RESUMO

Respiratory rate (fR) monitoring through wearable devices is crucial in several scenarios, providing insights into well-being and sports performance while minimizing interference with daily activities. Strain sensors embedded into garments stand out but require thorough investigation for optimal deployment. Optimal sensor positioning is often overlooked, and when addressed, the quality of the respiratory signal is neglected. Additionally, sensor metrological characterization after sensor integration is often omitted. In this study, we present the design, development, and feasibility assessment of a smart t-shirt embedded with two flexible sensors for fR monitoring. Guided by a motion capture system, optimal sensor design and position on the chest wall were defined, considering both signal magnitude and quality. The sensors were developed, embedded into the wearable system, and metrologically characterized, demonstrating a remarkable response to both static (sensitivity 9.4 Ω⋅%-1 and 9.1 Ω⋅%-1 for sensor A and sensor B, respectively) and cyclic loads (min. hysteresis span 20.4% at 36 bpm obtained for sensor A). The feasibility of the wearable system was assessed on healthy volunteers both under static and dynamic conditions (such as running, walking, and climbing stairs). A mean absolute error of 0.32 bpm was obtained by averaging all subjects and tests using the combination of the two sensors. This value was lower than that obtained using both sensor A (0.53 bpm) and sensor B (0.78 bpm) individually. Our study highlights the importance of signal amplitude and quality in optimal sensor placement evaluation, as well as the characterization of the embedded sensors for metrological assessment.


Assuntos
Corrida , Dispositivos Eletrônicos Vestíveis , Humanos , Monitorização Fisiológica , Taxa Respiratória , Têxteis
14.
Sensors (Basel) ; 24(10)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38793840

RESUMO

We propose the use of a specially designed polyurethane foam with a plateau region in its mechanical characteristics-where stress remains nearly constant during deformation-between the electromyography (EMG) electrode and clothing to suppress motion artifacts in EMG measurement. Wearable EMG devices are receiving attention for monitoring muscle weakening due to aging. However, daily EMG measurement has been challenging due to motion artifacts caused by changes in the contact pressure between the bioelectrode and the skin. Therefore, this study aims to measure EMG signals in daily movement environments by controlling the contact pressure using polyurethane foam between the bioelectrode on the clothing and the skin. Through mechanical calculations and finite element method simulations of the polyurethane foam's effect, we clarified that the characteristics of the polyurethane foam significantly influence contact pressure control and that the contact pressure is adjustable through the polyurethane foam thickness. The optimization of the design successfully controlled the contact pressure between the bioelectrode and skin from 1.0 kPa to 2.0 kPa, effectively suppressing the motion artifact in EMG measurement.


Assuntos
Artefatos , Eletromiografia , Poliuretanos , Dispositivos Eletrônicos Vestíveis , Poliuretanos/química , Eletromiografia/métodos , Eletromiografia/instrumentação , Humanos , Eletrodos , Movimento (Física)
15.
Sensors (Basel) ; 24(10)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38794011

RESUMO

Livestock monitoring is a task traditionally carried out through direct observation by experienced caretakers. By analyzing its behavior, it is possible to predict to a certain degree events that require human action, such as calving. However, this continuous monitoring is in many cases not feasible. In this work, we propose, develop and evaluate the accuracy of intelligent algorithms that operate on data obtained by low-cost sensors to determine the state of the animal in the terms used by the caregivers (grazing, ruminating, walking, etc.). The best results have been obtained using aggregations and averages of the time series with support vector classifiers and tree-based ensembles, reaching accuracies of 57% for the general behavior problem (4 classes) and 85% for the standing behavior problem (2 classes). This is a preliminary step to the realization of event-specific predictions.


Assuntos
Algoritmos , Aprendizado de Máquina , Animais , Bovinos , Comportamento Animal/fisiologia , Máquina de Vetores de Suporte , Humanos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
16.
Sensors (Basel) ; 24(13)2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-39001101

RESUMO

With the development of technology, people's demand for pressure sensors with high sensitivity and a wide working range is increasing. An effective way to achieve this goal is simulating human skin. Herein, we propose a facile, low-cost, and reproducible method for preparing a skin-like multi-layer flexible pressure sensor (MFPS) device with high sensitivity (5.51 kPa-1 from 0 to 30 kPa) and wide working pressure range (0-200 kPa) by assembling carbonized fabrics and micro-wrinkle-structured Ag@rGO electrodes layer by layer. In addition, the highly imitated skin structure also provides the device with an extremely short response time (60/90 ms) and stable durability (over 3000 cycles). Importantly, we integrated multiple sensor devices into gloves to monitor finger movements and behaviors. In summary, the skin-like MFPS device has significant potential for real-time monitoring of human activities in the field of flexible wearable electronics and human-machine interaction.


Assuntos
Fibra de Algodão , Pressão , Dispositivos Eletrônicos Vestíveis , Humanos , Fibra de Algodão/análise , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Eletrodos , Pele , Têxteis , Atividades Humanas
17.
Sensors (Basel) ; 24(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38544207

RESUMO

The remote monitoring of vital signs and healthcare provision has become an urgent necessity due to the impact of the COVID-19 pandemic on the world. Blood oxygen level, heart rate, and body temperature data are crucial for managing the disease and ensuring timely medical care. This study proposes a low-cost wearable device employing non-contact sensors to monitor, process, and visualize critical variables, focusing on body temperature measurement as a key health indicator. The wearable device developed offers a non-invasive and continuous method to gather wrist and forehead temperature data. However, since there is a discrepancy between wrist and actual forehead temperature, this study incorporates statistical methods and machine learning to estimate the core forehead temperature from the wrist. This research collects 2130 samples from 30 volunteers, and both the statistical least squares method and machine learning via linear regression are applied to analyze these data. It is observed that all models achieve a significant fit, but the third-degree polynomial model stands out in both approaches. It achieves an R2 value of 0.9769 in the statistical analysis and 0.9791 in machine learning.


Assuntos
Temperatura Corporal , Dispositivos Eletrônicos Vestíveis , Humanos , Punho/fisiologia , Temperatura , Pandemias
18.
Sensors (Basel) ; 24(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610281

RESUMO

In this study, we propose a low-cost piezoelectric flexible pressure sensor fabricated on Kapton® (Kapton™ Dupont) substrate by using aluminum nitride (AlN) thin film, designed for the monitoring of the respiration rate for a fast detection of respiratory anomalies. The device was characterized in the range of 15-30 breaths per minute (bpm), to simulate moderate difficult breathing, borderline normal breathing, and normal spontaneous breathing. These three breathing typologies were artificially reproduced by setting the expiratory to inspiratory ratios (E:I) at 1:1, 2:1, 3:1. The prototype was able to accurately recognize the breath states with a low response time (~35 ms), excellent linearity (R2 = 0.997) and low hysteresis. The piezoelectric device was also characterized by placing it in an activated carbon filter mask to evaluate the pressure generated by exhaled air through breathing acts. The results indicate suitability also for the monitoring of very weak breath, exhibiting good linearity, accuracy, and reproducibility, in very low breath pressures, ranging from 0.09 to 0.16 kPa. These preliminary results are very promising for the future development of smart wearable devices able to monitor different patients breathing patterns, also related to breathing diseases, providing a suitable real-time diagnosis in a non-invasive and fast way.


Assuntos
Respiração , Taxa Respiratória , Humanos , Reprodutibilidade dos Testes , Compostos de Alumínio
19.
Sensors (Basel) ; 24(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38610437

RESUMO

Computer vision (CV)-based systems using cameras and recognition algorithms offer touchless, cost-effective, precise, and versatile hand tracking. These systems allow unrestricted, fluid, and natural movements without the constraints of wearable devices, gaining popularity in human-system interaction, virtual reality, and medical procedures. However, traditional CV-based systems, relying on stationary cameras, are not compatible with mobile applications and demand substantial computing power. To address these limitations, we propose a portable hand-tracking system utilizing the Leap Motion Controller 2 (LMC) mounted on the head and controlled by a single-board computer (SBC) powered by a compact power bank. The proposed system enhances portability, enabling users to interact freely with their surroundings. We present the system's design and conduct experimental tests to evaluate its robustness under variable lighting conditions, power consumption, CPU usage, temperature, and frame rate. This portable hand-tracking solution, which has minimal weight and runs independently of external power, proves suitable for mobile applications in daily life.


Assuntos
Antebraço , Dispositivos Eletrônicos Vestíveis , Humanos , Extremidade Superior , Mãos , Algoritmos
20.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475162

RESUMO

An educational augmented reality auscultation system (EARS) is proposed to enhance the reality of auscultation training using a simulated patient. The conventional EARS cannot accurately reproduce breath sounds according to the breathing of a simulated patient because the system instructs the breathing rhythm. In this study, we propose breath measurement methods that can be integrated into the chest piece of a stethoscope. We investigate methods using the thoracic variations and frequency characteristics of breath sounds. An accelerometer, a magnetic sensor, a gyro sensor, a pressure sensor, and a microphone were selected as the sensors. For measurement with the magnetic sensor, we proposed a method by detecting the breathing waveform in terms of changes in the magnetic field accompanying the surface deformation of the stethoscope based on thoracic variations using a magnet. During breath sound measurement, the frequency spectra of the breath sounds acquired by the built-in microphone were calculated. The breathing waveforms were obtained from the difference in characteristics between the breath sounds during exhalation and inhalation. The result showed the average value of the correlation coefficient with the reference value reached 0.45, indicating the effectiveness of this method as a breath measurement method. And the evaluations suggest more accurate breathing waveforms can be obtained by selecting the measurement method according to breathing method and measurement point.


Assuntos
Realidade Aumentada , Estetoscópios , Humanos , Auscultação , Respiração , Expiração , Sons Respiratórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA