Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.418
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Physiol ; 602(10): 2227-2251, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38690610

RESUMO

Passive whole-body hyperthermia increases limb blood flow and cardiac output ( Q ̇ $\dot Q$ ), but the interplay between peripheral and central thermo-haemodynamic mechanisms remains unclear. Here we tested the hypothesis that local hyperthermia-induced alterations in peripheral blood flow and blood kinetic energy modulate flow to the heart and Q ̇ $\dot Q$ . Body temperatures, regional (leg, arm, head) and systemic haemodynamics, and left ventricular (LV) volumes and functions were assessed in eight healthy males during: (1) 3 h control (normothermic condition); (2) 3 h of single-leg heating; (3) 3 h of two-leg heating; and (4) 2.5 h of whole-body heating. Leg, forearm, and extracranial blood flow increased in close association with local rises in temperature while brain perfusion remained unchanged. Increases in blood velocity with small to no changes in the conduit artery diameter underpinned the augmented limb and extracranial perfusion. In all heating conditions, Q ̇ $\dot Q$ increased in association with proportional elevations in systemic vascular conductance, related to enhanced blood flow, blood velocity, vascular conductance and kinetic energy in the limbs and head (all R2 ≥ 0.803; P < 0.001), but not in the brain. LV systolic (end-systolic elastance and twist) and diastolic functional profiles (untwisting rate), pulmonary ventilation and systemic aerobic metabolism were only altered in whole-body heating. These findings substantiate the idea that local hyperthermia-induced selective alterations in peripheral blood flow modulate the magnitude of flow to the heart and Q ̇ $\dot Q$ through changes in blood velocity and kinetic energy. Localised heat-activated events in the peripheral circulation therefore affect the human heart's output. KEY POINTS: Local and whole-body hyperthermia increases limb and systemic perfusion, but the underlying peripheral and central heat-sensitive mechanisms are not fully established. Here we investigated the regional (leg, arm and head) and systemic haemodynamics (cardiac output: Q ̇ $\dot Q$ ) during passive single-leg, two-leg and whole-body hyperthermia to determine the contribution of peripheral and central thermosensitive factors in the control of human circulation. Single-leg, two-leg, and whole-body hyperthermia induced graded increases in leg blood flow and Q ̇ $\dot Q$ . Brain blood flow, however, remained unchanged in all conditions. Ventilation, extracranial blood flow and cardiac systolic and diastolic functions only increased during whole-body hyperthermia. The augmented Q ̇ $\dot Q$ with hyperthermia was tightly related to increased limb and head blood velocity, flow and kinetic energy. The findings indicate that local thermosensitive mechanisms modulate regional blood velocity, flow and kinetic energy, thereby controlling the magnitude of flow to the heart and thus the coupling of peripheral and central circulation during hyperthermia.


Assuntos
Débito Cardíaco , Hipertermia , Humanos , Masculino , Adulto , Hipertermia/fisiopatologia , Débito Cardíaco/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Febre/fisiopatologia , Adulto Jovem , Temperatura Alta , Hemodinâmica
2.
J Transl Med ; 22(1): 285, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493167

RESUMO

BACKGROUND: Lactate is traditionally recognized as a by-product of anaerobic metabolism. However, lactate is a preferred oxidative substrate for stressed myocardium. Exogenous lactate infusion increases cardiac output (CO). The exact mechanism underlying this mechanism has yet to be elucidated. The aim of this study was to investigate the cardiovascular mechanisms underlying the acute haemodynamic effects of exogenous lactate infusion in an experimental model of human-sized pigs. METHODS: In this randomised, blinded crossover study in eight 60-kg-pigs, the pigs received infusions with one molar sodium lactate and a control infusion of tonicity matched hypertonic saline in random order. We measured CO and pulmonary pressures using a pulmonary artery catheter. A pressure-volume admittance catheter in the left ventricle was used to measure contractility, afterload, preload and work-related parameters. RESULTS: Lactate infusion increased circulating lactate levels by 9.9 mmol/L (95% confidence interval (CI) 9.1 to 11.0) and CO by 2.0 L/min (95% CI 1.2 to 2.7). Afterload decreased as arterial elastance fell by  -1.0 mmHg/ml (95% CI  -2.0 to  -0.1) and systemic vascular resistance decreased by  -548 dynes/s/cm5 (95% CI  -261 to  -835). Mixed venous saturation increased by 11 percentage points (95% CI 6 to 16), whereas ejection fraction increased by 16.0 percentage points (95% CI 1.1 to 32.0) and heart rate by 21 bpm (95% CI 8 to 33). No significant changes in contractility nor preload were observed. CONCLUSION: Lactate infusion increased cardiac output by increasing heart rate and lowering afterload. No differences were observed in left ventricular contractility or preload. Lactate holds potential as a treatment in situations with lowered CO and should be investigated in future clinical studies.


Assuntos
Hemodinâmica , Ácido Láctico , Animais , Débito Cardíaco/fisiologia , Estudos Cross-Over , Frequência Cardíaca , Suínos , Resistência Vascular
3.
Eur Radiol ; 34(3): 1825-1835, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37650970

RESUMO

OBJECTIVES: Left ventricle function directly impacts left atrial (LA) conduit function, and LA conduit strain is associated with exercise intolerance in patients with heart failure with preserved ejection fraction (HFpEF). Pulmonary capillary wedge pressure (PCWP) before and during exercise is the current gold standard for diagnosing HFpEF. Post-exercise ΔPCWP can lead to worse long-term outcomes. This study examined the correlation between LA strain and post-exercise ΔPCWP in patients with HFpEF. METHODS: We enrolled 100 subjects, including 74 with HFpEF and 26 with non-cardiac dyspnea, from November 2017 to December 2020. Subjects underwent echocardiography, invasive cardiac catheterization, and expired gas analysis at rest and during exercise. Arterial blood pressure, right atrial pressure, pulmonary artery pressure, and PCWP were recorded during cardiac catheterization. Cardiac output, stroke volume, pulmonary vascular resistance, pulmonary artery compliance, systemic vascular resistance, and LV stroke work were calculated using standard formulas. RESULTS: Exercise LA conduit strain significantly correlated with both post-exercise ΔPCWP (r = - 0.707, p < 0.001) and exercise PCWP (r = - 0.659; p < 0.001). Exercise LA conduit strain differentiated patients who did and did not meet the 2016 European Society of Cardiology HFpEF criteria with an area under the curve of 0.69 (95% confidence interval, 0.548-0.831) using a cutoff value of 14.25, with a sensitivity of 0.64 and a specificity of 0.68. CONCLUSIONS: Exercise LA conduit strain significantly correlates with post-exercise ΔPCWP and has a comparable power to identify patients with HFpEF. Additional studies are warranted to confirm the ability of LA conduit strain to predict long-term outcomes among patients with HFpEF. CLINICAL RELEVANCE STATEMENT: Exercise left atrial conduit strain was highly associated with the difference of post-exercise pulmonary capillary wedge pressure and may indicate increased mortality risk in patients with heart failure with preserved ejection fraction, and also has comparable diagnostic ability. KEY POINTS: • Left atrial conduit strain is associated with exercise intolerance in patients with heart failure with preserved ejection fraction. • Left atrial conduit strain during exercise can identify patients with heart failure with preserved ejection fraction. • Exercise left atrial conduit strain significantly correlates with the difference of pulmonary capillary wedge pressure during and before exercise which might predict the long-term outcomes of heart failure with preserved ejection fraction patients.


Assuntos
Insuficiência Cardíaca , Humanos , Volume Sistólico/fisiologia , Hemodinâmica , Débito Cardíaco/fisiologia , Pressão Propulsora Pulmonar/fisiologia , Função Ventricular Esquerda/fisiologia
4.
Curr Opin Crit Care ; 30(3): 251-259, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38690954

RESUMO

PURPOSE OF REVIEW: To describe current and near future developments and applications of CO2 kinetics in clinical respiratory and cardiovascular monitoring. RECENT FINDINGS: In the last years, we have witnessed a renewed interest in CO2 kinetics in relation with a better understanding of volumetric capnography and its derived parameters. This together with technological advances and improved measurement systems have expanded the monitoring potential of CO2 kinetics including breath by breath continuous end-expiratory lung volume and continuous noninvasive cardiac output. Dead space has slowly been gaining relevance in clinical monitoring and prognostic evaluation. Easy to measure dead space surrogates such as the ventilatory ratio have demonstrated a strong prognostic value in patients with acute respiratory failure. SUMMARY: The kinetics of carbon dioxide describe many relevant physiological processes. The clinical introduction of new ways of assessing respiratory and circulatory efficiency based on advanced analysis of CO2 kinetics are paving the road to a long-desired goal in clinical monitoring of critically ill patients: the integration of respiratory and circulatory monitoring during mechanical ventilation.


Assuntos
Capnografia , Dióxido de Carbono , Humanos , Dióxido de Carbono/análise , Capnografia/métodos , Monitorização Fisiológica/métodos , Respiração Artificial/métodos , Cinética , Débito Cardíaco/fisiologia , Biomarcadores , Espaço Morto Respiratório/fisiologia
5.
Ultrasound Obstet Gynecol ; 63(2): 198-205, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37325858

RESUMO

OBJECTIVE: Maternal cardiac function plays a crucial role in placental function and development. The maternal hemodynamic changes in twin pregnancy are more pronounced than those in singleton pregnancy, presumably due to a greater plasma volume expansion. In view of the correlation between maternal cardiac and placental function, it is plausible that chorionicity could influence maternal cardiac function. The aim of this study was to compare the longitudinal maternal hemodynamic changes between uncomplicated dichorionic (DC) and monochorionic (MC) twin pregnancies and in comparison to singleton pregnancies. METHODS: Included in the study were 40 MC diamniotic and 35 DC diamniotic uncomplicated twin pregnancies. These were compared with a group of 294 healthy singleton pregnancies from a previous cross-sectional study. All participants underwent a hemodynamic evaluation using an Ultrasound Cardiac Output Monitor (USCOM®), at three different stages in pregnancy (11-15 weeks, 20-24 weeks and 29-33 weeks). The following parameters were recorded: mean arterial pressure (MAP), stroke volume (SV), stroke volume index (SVI), heart rate, cardiac output (CO), cardiac index (CI), systemic vascular resistance (SVR), systemic vascular resistance index (SVRI), stroke volume variation, Smith-Madigan inotropy index (INO) and potential-to-kinetic-energy ratio (PKR). RESULTS: In the first trimester, DC and MC twin pregnancies showed lower MAP, SVR and PKR and higher CO and SV in comparison to singleton pregnancy. In the second trimester, maternal CO (8.33 vs 7.30 L/min, P = 0.03) and CI (4.52 vs 4.00 L/min/m2 , P = 0.02) were significantly higher in MC compared with DC twin pregnancy. In the third trimester, compared with in singleton pregnancy, women with MC twin pregnancy showed significantly higher PKR (24.06 vs 20.13, P = 0.03) and SVRI (1837.20 vs 1698.48 dynes × s/cm5 /m2 , P = 0.03), and significantly lower SV (78.80 vs 88.80 mL, P = 0.01), SVI (42.79 vs 50.31 mL/m2 , P < 0.01) and INO (1.70 vs 1.87 W/m2 , P = 0.03); these differences were not observed between DC twin and singleton pregnancies. CONCLUSIONS: Maternal cardiovascular function undergoes significant change during uncomplicated twin pregnancy and chorionicity influences maternal hemodynamics. In both MC and DC twin pregnancy, hemodynamic changes are detectable as early as the first trimester, showing higher maternal CO and lower SVR compared with singleton pregnancy. In DC twin pregnancy, the maternal hemodynamics remain stable during the rest of pregnancy. In contrast, in MC twin pregnancy, the rise in maternal CO continues in the second trimester in order to sustain the greater placental growth. There is a subsequent crossover, with a reduction in cardiovascular performance during the third trimester. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Placenta , Gravidez de Gêmeos , Gravidez , Feminino , Humanos , Gravidez de Gêmeos/fisiologia , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia , Gêmeos Dizigóticos
6.
J Intensive Care Med ; 39(7): 628-635, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38190576

RESUMO

Background: The likelihood of a patient being preload responsive-a state where the cardiac output or stroke volume (SV) increases significantly in response to preload-depends on both cardiac filling and function. This relationship is described by the canonical Frank-Starling curve. Research Question: We hypothesize that a novel method for phenotyping hypoperfused patients (ie, the "Doppler Starling curve") using synchronously measured jugular venous Doppler as a marker of central venous pressure (CVP) and corrected flow time of the carotid artery (ccFT) as a surrogate for SV will refine the pretest probability of preload responsiveness/unresponsiveness. Study Design and Methods: We retrospectively analyzed a prospectively collected convenience sample of hypoperfused adult emergency department (ED) patients. Doppler measurements were obtained before and during a preload challenge using a wireless, wearable Doppler ultrasound system. Based on internal jugular and carotid artery Doppler surrogates of CVP and SV, respectively, we placed hemodynamic assessments into quadrants (Qx) prior to preload augmentation: low CVP with normal SV (Q1), high CVP and normal SV (Q2), low CVP and low SV (Q3) and high CVP and low SV (Q4). The proportion of preload responsive and unresponsive assessments in each quadrant was calculated based on the maximal change in ccFT (ccFTΔ) during either a passive leg raise or rapid fluid challenge. Results: We analyzed 41 patients (68 hemodynamic assessments) between February and April 2021. The prevalence of each phenotype was: 15 (22%) in Q1, 8 (12%) in Q2, 39 (57%) in Q3, and 6 (9%) in Q4. Preload unresponsiveness rates were: Q1, 20%; Q2, 50%; Q3, 33%, and Q4, 67%. Interpretation: Even fluid naïve ED patients with sonographic estimates of low CVP have high rates of fluid unresponsiveness, making dynamic testing valuable to prevent ineffective IVF administration.


Assuntos
Artérias Carótidas , Hidratação , Veias Jugulares , Ultrassonografia Doppler , Humanos , Projetos Piloto , Masculino , Feminino , Hidratação/métodos , Pessoa de Meia-Idade , Veias Jugulares/diagnóstico por imagem , Estudos Prospectivos , Artérias Carótidas/diagnóstico por imagem , Idoso , Ressuscitação/métodos , Pressão Venosa Central/fisiologia , Estudos Retrospectivos , Adulto , Volume Sistólico/fisiologia , Débito Cardíaco/fisiologia , Serviço Hospitalar de Emergência , Hemodinâmica
7.
Eur J Pediatr ; 183(4): 1849-1855, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38276999

RESUMO

Clinical parameters used for hemodynamic assessment and titration of vasopressor therapy in neonates with septic shock have several limitations. Functional echocardiography is an emerging tool for bedside assessment of cardiac function and may be useful for diagnosis of shock and assessing the response to therapy. Data regarding echocardiographic parameters in neonates with shock is lacking. This prospective observational study was conducted in a Level III NICU with the primary objective of comparing echocardiographic characteristics of neonates with septic shock at diagnosis, following fluid boluses, and after maximum inotropic support [A1]. Additionally, we compared these characteristics with those of healthy stable neonates who were gestation and postnatal age-matched. A total of 36 neonates with septic shock and 30 gestation and postnatal age-matched controls were enrolled. The mean (SD) gestation and birth weight of neonates with septic shock were 30.6 (4.0) weeks and 1538 (728) g, respectively. Gram-negative bacilli constituted 78.9% of all isolates. At presentation, there was no significant difference between neonates with shock and controls in terms of ventricular outputs, shortening fraction, ratio of early to late diastolic trans-mitral flow velocity, and myocardial performance indices. The distensibility index of inferior vena cava was higher in neonates with shock compared to controls, (17% vs 10%, (p < 0.01)). Left ventricular output was 209 (92) and 227 (102) ml/kg/min (p = 0.53) and right ventricular output was 427 (203) and 459 (227) ml/kg/min, (p = 0.03), respectively, before and after inotropic therapy.     Conclusion: Echocardiographic parameters may not differentiate neonates with septic shock from hemodynamically stable neonates. Neonates with shock associated with predominantly gram-negative sepsis are not able to augment cardiac functions, either at the onset or after administration of inotropes.      Trial registration: (CTRI/2017/12/010766). What is known: • For neonates with shock, echocardiography is becoming increasingly popular as an objective method of evaluating hemodynamics. • In healthy preterm neonate, cardiac output has been known to increase in response to altered hemodynamics during states of increased oxygen demand. What is new: •  In the setting of septic shock induced by gram-negative organisms, echocardiographic parameters are less likely to assist in the assessment of the response to vasoactive agents. Cytokines, induced by gram-negative organisms, may alter adrenoreceptors in myocardium and vasculature.


Assuntos
Choque Séptico , Recém-Nascido , Humanos , Choque Séptico/diagnóstico por imagem , Choque Séptico/terapia , Ecocardiografia , Hemodinâmica , Débito Cardíaco/fisiologia , Ventrículos do Coração
8.
Eur J Pediatr ; 183(5): 2183-2192, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376594

RESUMO

We aimed to establish reference ranges for USCOM parameters in preterm infants, determine factors that affect cardiac output, and evaluate the measurement repeatability. This retro-prospective study was performed at Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy. We included infants below 32 weeks of gestational age (GA) and/or 1500 g of birth weight (BW). We excluded infants with congenital heart diseases or hemodynamic instability. Measurements were performed at 3 ± 1, 7 ± 2, and 14 ± 2 postnatal days. We analyzed 204 measurements from 92 patients (median GA = 30.57 weeks, BW = 1360 g). The mean (SD) cardiac output (CO) was 278 (55) ml/min/kg, cardiac index (CI) was 3.1 (0.5) L/min/m2, and systemic vascular resistance (SVRI) was 1292 (294) d*s*cm-5/m2. CO presented a negative correlation with postmenstrual age (PMA), while SVRI presented a positive correlation with PMA. The repeatability coefficient was 31 ml/kg/min (12%).  Conclusion: This is the first study describing reference values for USCOM parameters in hemodynamically stable preterm infants and factors affecting their variability. Further studies to investigate the usefulness of USCOM for the longitudinal assessment of patients at risk for cardiovascular instability or monitoring the response to therapies are warranted. What is Known: • The ultrasonic cardiac output monitoring (USCOM) has been widely used on adult and pediatric patients and reference ranges for cardiac output (CO) by USCOM have been established in term infants. What is New: • We established reference values for USCOM parameters in very preterm and very-low-birth-weight infants; the reference ranges for CO by USCOM in the study population were 198-405 ml/kg/min. • CO normalized by body weight presented a significant negative correlation with postmenstrual age (PMA); systemic vascular resistance index presented a significant positive correlation with PMA.


Assuntos
Débito Cardíaco , Recém-Nascido Prematuro , Humanos , Recém-Nascido , Débito Cardíaco/fisiologia , Masculino , Feminino , Valores de Referência , Estudos Prospectivos , Estudos Retrospectivos , Hemodinâmica/fisiologia , Reprodutibilidade dos Testes , Idade Gestacional , Monitorização Fisiológica/métodos , Resistência Vascular/fisiologia
9.
Scand J Med Sci Sports ; 34(1): e14495, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37724816

RESUMO

Sex differences in the cardiorespiratory and hemodynamic response to exercise exist due to differences in heart size, blood volume, and hemoglobin mass, eliciting higher maximal oxygen uptake (VO2max ) in men versus women. Data are equivocal whether sex differences in training responsiveness occur. This study investigated potential sex differences in the hemodynamic response (stroke volume (SV) and cardiac output (CO)) to high-intensity interval exercise (HIIE). Habitually active men (n = 15) and women (n = 13) underwent VO2max testing, followed by three HIIE sessions consisting of the 4 × 4, 10 × 1, and reduced exertion high-intensity training (REHIT), whose order was randomized. During exercise, oxygen uptake (VO2 ) and hemodynamic responses were determined. Results showed no sex difference in peak relative VO2 (p = 0.263), CO (p = 0.277), or SV (p = 0.116), although absolute values were higher in men (p < 0.05). Peak absolute (127.3 ± 20.6 vs. 115.2 ± 16.6 mL/beat, p = 0.004, d = 0.66) and relative SV (111.0 ± 15.5 vs. 100.7 ± 11.1% max, p = 0.005, d = 0.78) were higher with REHIT versus 4 × 4. No sex differences in mean relative VO2 , CO, or SV occurred (p > 0.05). Data showed lower mean VO2 during REHIT versus 4 × 4 (59.3 ± 6.8 vs. 65.8 ± 5.8 %VO2max , p < 0.001, d = 1.05) and 10 × 1 (59.3 ± 6.8 vs. 69.1 ± 7.4 %VO2max , p < 0.001, d = 1.4). Mean CO was lower in REHIT than 10 × 1 (79.8 ± 8.6 vs. 84.0 ± 7.4% max, p = 0.012, d = 0.53). Previously reported differences in VO2max response to HIIE may not be due to unique hemodynamic responses.


Assuntos
Treinamento Intervalado de Alta Intensidade , Caracteres Sexuais , Humanos , Feminino , Masculino , Exercício Físico/fisiologia , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia , Consumo de Oxigênio/fisiologia , Oxigênio
10.
BMC Anesthesiol ; 24(1): 201, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844869

RESUMO

BACKGROUND: Significant hemodynamic changes occur during liver transplantation, emphasizing the importance of precious and continuous monitoring of cardiac output, cardiac index, and other parameters. Although the monitoring of cardiac output by pulse indicator continuous cardiac output (PiCCO) was statistically homogeneous compared to the clinical gold standard pulmonary artery catheterization (PAC) in previous studies of liver transplantation, there are fewer statistical methods for the assessment of its conclusions, and a lack of comparisons of other hemodynamic parameters (e.g., SVRI, systemic vascular resistance index). Some studies have also concluded that the agreement between PiCCO and PAC is not good enough. Overall, there are no uniform conclusions regarding the agreement between PiCCO and PAC in previous studies. This study evaluates the agreement and trending ability of relevant hemodynamic parameters obtained with PiCCO compared to the clinical gold standard PAC from multiple perspectives, employing various statistical methods. METHODS: Fifty-two liver transplantation patients were included. Cardiac output (CO), cardiac index (CI), SVRI and stroke volume index (SVI) values were monitored at eight time points using both PiCCO and PAC. The results were analyzed by Bland-Altman analysis, Passing-bablok regression, intra-class correlation coefficient (ICC), 4-quadrant plot, polar plot, and trend interchangeability method (TIM). RESULTS: The Bland-Altman analysis revealed high percentage errors for PiCCO: 54.06% for CO, 52.70% for CI, 62.18% for SVRI, and 51.97% for SVI, indicating poor accuracy. While Passing-Bablok plots showed favorable agreement for SVRI overall and during various phases, the agreement for other parameters was less satisfactory. The ICC results confirmed good overall agreement between the two devices across most parameters, except for SVRI during the new liver phase, which showed poor agreement. Additionally, four-quadrant and polar plot analyses indicated that all agreement rate values fell below the clinically acceptable threshold of over 90%, and all angular deviation values exceeded ± 5°, demonstrating that PiCCO is unable to meet the acceptable trends. Using the TIM, the interchangeability rates were found to be quite low: 20% for CO and CI, 16% for SVRI, and 13% for SVI. CONCLUSIONS: Our study revealed notable disparities in absolute values of CO, CI, SVRI and SVI between PiCCO and PAC in intraoperative liver transplant settings, notably during the neohepatic phase where errors were particularly pronounced. Consequently, these findings highlight the need for careful consideration of PiCCO's advantages and disadvantages in liver transplantation scenarios, including its multiple parameters (such as the encompassing extravascular lung water index), against its limited correlation with PAC.


Assuntos
Débito Cardíaco , Cateterismo de Swan-Ganz , Hemodinâmica , Transplante de Fígado , Monitorização Intraoperatória , Transplante de Fígado/métodos , Humanos , Cateterismo de Swan-Ganz/métodos , Débito Cardíaco/fisiologia , Masculino , Pessoa de Meia-Idade , Feminino , Hemodinâmica/fisiologia , Monitorização Intraoperatória/métodos , Idoso , Adulto , Artéria Pulmonar/fisiologia
11.
Eur J Appl Physiol ; 124(7): 2183-2192, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38441687

RESUMO

Cardiovascular responses to diving are characterized by two opposing responses: tachycardia resulting from exercise and bradycardia resulting from the apnea. The convergence of bradycardia and tachycardia may determine the cardiovascular responses to diving. The purpose of this study was to investigate the interaction of breath holding and muscle mechanoreflex on cardiovascular responses in breath-hold divers (BHDs) and non-BHDs. We compared the cardiovascular responses to combined apnea and the mechanoreflex in BHDs and non-BHDs. All participants undertook three trials-apnea, passive leg cycling (PLC), and combined trials-for 30 s after rest. Cardiovascular variables were measured continuously. Nine BHD (male:female, 4:5; [means ± SD] age, 35 ± 6 years; height, 168.6 ± 4.6 cm; body mass, 58.4 ± 5.9 kg) and eight non-BHD (male:female, 4:4; [means ± SD] age, 35 ± 7 years; height, 163.9 ± 9.1 cm; body mass, 55.6 ± 7.2 kg) participants were included. Compared to the resting baseline, heart rate (HR) and cardiac output (CO) significantly decreased during the combined trial in the BHD group, while they significantly increased during the combined trials in the non-BHD group (P < 0.05). Changes in the HR and CO were significantly lower in the BHD group than in the non-BHD group in the combined trial (P < 0.05). These results suggest that bradycardia with apnea in BHDs is prioritized over tachycardia with the mechanoreflex, whereas that in non-BHDs is not. This finding implies that diving training changes the interaction between apnea and the mechanoreflex in cardiovascular control.


Assuntos
Suspensão da Respiração , Mergulho , Frequência Cardíaca , Humanos , Masculino , Feminino , Adulto , Mergulho/fisiologia , Frequência Cardíaca/fisiologia , Músculo Esquelético/fisiologia , Músculo Esquelético/fisiopatologia , Apneia/fisiopatologia , Reflexo/fisiologia , Débito Cardíaco/fisiologia , Reflexo de Mergulho/fisiologia , Pressão Sanguínea/fisiologia
12.
BMC Anesthesiol ; 24(1): 187, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38796436

RESUMO

PURPOSE: Oxygen delivery (DO2) and its monitoring are highlighted to aid postoperative goal directed therapy (GDT) to improve perioperative outcomes such as acute kidney injury (AKI) after high-risk cardiac surgeries associated with multiple morbidities and mortality. However, DO2 monitoring is neither routine nor done postoperatively, and current methods are invasive and only produce intermittent DO2 trends. Hence, we proposed a novel algorithm that simultaneously integrates cardiac output (CO), hemoglobin (Hb) and oxygen saturation (SpO2) from the Edwards Life Sciences ClearSight System® and Masimo SET Pulse CO-Oximetry® to produce a continuous, real-time DO2 trend. METHODS: Our algorithm was built systematically with 4 components - machine interface to draw data with PuTTY, data extraction with parsing, data synchronization, and real-time DO2 presentation using a graphic-user interface. Hb readings were validated. RESULTS: Our algorithm was implemented successfully in 93% (n = 57 out of 61) of our recruited cardiac surgical patients. DO2 trends and AKI were studied. CONCLUSION: We demonstrated a novel proof-of-concept and feasibility of continuous, real-time, non-invasive DO2 monitoring, with each patient serving as their own control. Our study also lays the foundation for future investigations aimed at identifying personalized critical DO2 thresholds and optimizing DO2 as an integral part of GDT to enhance outcomes in perioperative cardiac surgery.


Assuntos
Algoritmos , Procedimentos Cirúrgicos Cardíacos , Estudos de Viabilidade , Oximetria , Oxigênio , Humanos , Procedimentos Cirúrgicos Cardíacos/métodos , Masculino , Feminino , Oxigênio/metabolismo , Oxigênio/administração & dosagem , Oxigênio/sangue , Oximetria/métodos , Idoso , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Injúria Renal Aguda , Monitorização Fisiológica/métodos , Débito Cardíaco/fisiologia , Hemoglobinas/metabolismo , Hemoglobinas/análise , Saturação de Oxigênio/fisiologia
13.
J Cardiothorac Vasc Anesth ; 38(2): 417-422, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38114369

RESUMO

OBJECTIVES: The IKORUS system (Vygon, Écouen, France) allows continuous monitoring of the urethral perfusion index (uPI) using a photoplethysmographic sensor mounted near the base of the balloon of a dedicated urinary catheter. We aimed to test the hypothesis that the uPI decreases during off-pump coronary artery bypass (OPCAB) surgery and to investigate the relationship between the uPI and macrocirculatory variables. DESIGN: Prospective observational study. SETTING: University Medical Center Hamburg-Eppendorf, Hamburg, Germany. PARTICIPANTS: Twenty patients having OPCAB surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary endpoint was changes in the uPI during OPCAB surgery. We additionally investigated associations between the uPI and cardiac output, mean arterial pressure, heart rate, and point-of-care variables. Twenty patients with 24,137 uPI measurements were included. Overall, there was a high interindividual variability in the uPI. Compared with the preparation phase (during which the median [interquartile range] uPI was 7.7 [5.6-12.0]), the uPI decreased by 14% (95% CI 13%-15%) during the bypass grafting phase, by 35% (95% CI 34%-36%) during the cardiac positioning phase, and by 7% (95% CI 6%-9%) during hemostasis. There was no clinically important association between uPI and either cardiac output, mean arterial pressure, or heart rate. CONCLUSIONS: The uPI decreases during OPCAB surgery, specifically during the cardiac positioning phase. There was no clinically important association between uPI and either cardiac output, mean arterial pressure, or heart rate. It, therefore, remains to be determined whether intraoperative uPI decreases are clinically important, reflect alterations in intra-abdominal tissue perfusion that are not reflected by systemic macrohemodynamics, and can help clinicians guide therapeutic interventions.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Humanos , Pressão Arterial , Débito Cardíaco/fisiologia , Frequência Cardíaca/fisiologia , Índice de Perfusão , Estudos Prospectivos
14.
J Cardiothorac Vasc Anesth ; 38(7): 1484-1491, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38631929

RESUMO

OBJECTIVE: To investigate the accuracy, precision, and trending ability of noninvasive bioreactance-based Starling SV and the mini invasive pulse-power device LiDCOrapid as compared to thermodilution cardiac output (TDCO) as measured by pulmonary artery catheter when assessing cardiac index (CIx) in the setting of elective open abdominal aortic (AA) surgery. DESIGN: A prospective method-comparison study. SETTING: Oulu University Hospital, Finland. PARTICIPANTS: Forty patients undergoing elective open abdominal aortic surgery. INTERVENTIONS: Intraoperative CI measurements were obtained simultaneously with TDCO and the study monitors, resulting in 627 measurement pairs with Starling SV and 497 with LiDCOrapid. MEASUREMENTS AND MAIN RESULTS: The Bland-Altman method was used to investigate the agreement among the devices, and four-quadrant plots with error grids were used to assess trending ability. The agreement between TDCO and Starling SV was associated with a bias of 0.18 L/min/m2 (95% confidence interval [CI] = 0.13 to 0.23), wide limits of agreement (LOA = -1.12 to 1.47 L/min/m2), and a percentage error (PE) of 63.7 (95% CI = 52.4-71.0). The agreement between TDCO and LiDCOrapid was associated with a bias of -0.15 L/min/m2 (95% CI = -0.21 to -0.09), wide LOA (-1.56 to 1.37), and a PE of 68.7 (95% CI = 54.9-79.6). The trending ability of neither device was sufficient. CONCLUSION: The CI measurements achieved with Starling SV and LiDCOrapid were not interchangeable with TDCO, and the ability to track changes in CI was poor. These results do not support the use of either study device in monitoring CI during open AA surgery.


Assuntos
Aorta Abdominal , Débito Cardíaco , Monitorização Intraoperatória , Termodiluição , Humanos , Masculino , Feminino , Estudos Prospectivos , Débito Cardíaco/fisiologia , Idoso , Aorta Abdominal/cirurgia , Reprodutibilidade dos Testes , Monitorização Intraoperatória/métodos , Monitorização Intraoperatória/normas , Pessoa de Meia-Idade , Termodiluição/métodos , Procedimentos Cirúrgicos Vasculares/métodos
15.
Int J Sports Med ; 45(7): 532-542, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38267005

RESUMO

This study aimed to highlight the ventilatory and circulatory determinants of changes in ˙VO2peak after exercise-based cardiac rehabilitation (ECR) in patients with coronary heart disease (CHD). Eighty-two CHD patients performed, before and after a 3-month ECR, a cardiopulmonary exercise testing (CPET) on a bike with gas exchanges measurements (˙VO2peak, minute ventilation, i. e., ˙VE), and cardiac output (Q˙c). The arteriovenous difference in O2 (C(a-v¯)O2) and the alveolar capillary gradient in O2 (PAi-aO2) were calculated using Fick's laws. Oxygen uptake efficiency slope (OUES) was calculated. A 5.0% cut off was applied for differentiating non- (NR: ˙VO2<0.0%), low (LR: 0.0≤ ∆˙VO2<5.0%), moderate (MR: 5.0≤∆˙VO2 < 10.0%), and high responders (HR: ∆˙VO2≥10.0%) to ECR. A total of 44% of patients were HR (n=36), 20% MR (n=16), 23% LR (n=19), and 13% NR (n=11). For HR, the ˙VO2peak increase (p<0.01) was associated with increases in ˙VE (+12.8±13.0 L/min, p<0.01), (+1.0±0.9 L/min, p<0.01), and C(a-v¯)O2 (+2.3±2.5 mLO2/100 mL, p<0.01). MR patients were characterized by+6.7±19.7 L/min increase in ˙VE (p=0.04) and+0.7±1.0 L/min of Q˙c (p<0.01). ECR induced decreases in ˙VE (p=0.04) and C(a-v¯)O2 (p<0.01) and a Q˙c increase in LR and NR patients (p<0.01). Peripheral and ventilatory responses more than central adaptations could be responsible for the ˙VO2peak change with ECR in CHD patients.


Assuntos
Reabilitação Cardíaca , Doença das Coronárias , Teste de Esforço , Consumo de Oxigênio , Humanos , Masculino , Consumo de Oxigênio/fisiologia , Pessoa de Meia-Idade , Feminino , Doença das Coronárias/fisiopatologia , Doença das Coronárias/reabilitação , Reabilitação Cardíaca/métodos , Idoso , Terapia por Exercício/métodos , Débito Cardíaco/fisiologia , Troca Gasosa Pulmonar , Frequência Cardíaca/fisiologia
16.
Cardiol Young ; 34(2): 262-267, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37317547

RESUMO

BACKGROUND: Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance. METHODS: Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children's National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland-Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation. RESULTS: Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin's correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland-Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg. CONCLUSIONS: Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.


Assuntos
Transplante de Coração , Imageamento por Ressonância Magnética , Criança , Humanos , Reprodutibilidade dos Testes , Cateterismo Cardíaco , Oximetria/métodos , Débito Cardíaco/fisiologia , Espectroscopia de Ressonância Magnética
17.
J Anesth ; 38(1): 1-9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37740733

RESUMO

PURPOSE: Several technical aspects of the Fick method limit its use intraoperatively. A data-driven modification of the Fick method may enable its use in intraoperative settings. METHODS: This two-center retrospective observational study included 57 (28 and 29 in each center) patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery. Intraoperative recordings of physiological data were obtained and divided into training and test datasets. The Fick equation was used to calculate cardiac output (CO-Fick) using ventilator-determined variables, intraoperative hemoglobin level, and SvO2, with continuous thermodilution cardiac output (CCO) used as a reference. A modification CO-Fick was derived and validated: CO-Fick-AD, which adjusts the denominator of the original equation. RESULTS: Increased deviation between CO-Fick and CCO was observed when oxygen extraction was low. The root mean square error of CO-Fick was decreased from 6.07 L/min to 0.70 L/min after the modification. CO-Fick-AD showed a mean bias of 0.17 (95% CI 0.00-0.34) L/min, with a 36.4% (95% CI 30.6-44.4%) error. The concordance rates of CO-Fick-AD ranged from 73.3 to 87.1% depending on the time interval and exclusion zone. CONCLUSIONS: The original Fick method is not reliable when oxygen extraction is low, but a modification using data-driven approach could enable continuous estimation of cardiac output during the dynamic intraoperative period with minimal bias. However, further improvements in precision and trending ability are needed.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Humanos , Débito Cardíaco/fisiologia , Monitorização Fisiológica , Consumo de Oxigênio , Oxigênio , Termodiluição/métodos
18.
Curr Opin Organ Transplant ; 29(1): 72-81, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38032246

RESUMO

PURPOSE OF REVIEW: The purpose of this article is to provide a comprehensive review of hemodynamic monitoring in liver transplantation. RECENT FINDINGS: Radial arterial blood pressure monitoring underestimates the aortic root arterial blood pressure and causes excessive vasopressor and worse outcomes. Brachial and femoral artery monitoring is well tolerated and should be considered in critically ill patients expected to be on high dose pressors. The pulmonary artery catheter is the gold standard of hemodynamic monitoring and is still widely used in liver transplantation; however, it is a highly invasive monitor with potential for serious complications and most of its data can be obtained by other less invasive monitors. Rescue transesophageal echocardiography relies on few simple views and should be available as a standby to manage sudden hemodynamic instability. Risk of esophageal bleeding from transesophageal echocardiography in liver transplantation is the same as in other patient populations. The arterial pulse waveform analysis based cardiac output devices are minimally invasive and have the advantage of real-time beat to beat monitoring of cardiac output. No hemodynamic monitor can improve clinical outcomes unless integrated into a goal-directed hemodynamic therapy. The hemodynamic monitoring technique should be tailored to the patient's medical status, surgical technique, and the anesthesiologist's level of expertise. SUMMARY: The current article provides a review of the current hemodynamic monitoring systems and their integration in goal-directed hemodynamic therapy.


Assuntos
Monitorização Hemodinâmica , Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Hemodinâmica/fisiologia , Débito Cardíaco/fisiologia , Monitorização Fisiológica/métodos
19.
Zhonghua Fu Chan Ke Za Zhi ; 59(5): 375-382, 2024 May 25.
Artigo em Zh | MEDLINE | ID: mdl-38797567

RESUMO

Objective: To investigate the variation of reference ranges of hemodynamic parameters in normal pregnancy and their relation to maternal basic characteristics. Methods: A total of 598 healthy pregnant women who underwent regular prenatal examination at the Third Affiliated Hospital of Guangzhou Medical University from January to December 2023 were prospectively enrolled, and noninvasive hemodynamic monitors were used to detect changes in hemodynamic parameters of the pregnant women with the week of gestation, including cardiac output (CO), stroke volume (SV), thoracic fluid content (TFC), systemic vascular resistance (SVR), mean arterial pressure (MAP), and heart rate (HR). Relationships between hemodynamic parameters and maternal basic characteristics, including age, height, and weight, were analyzed using restricted cubic spline. Results: (1) CO (r=0.155, P<0.001), TFC (r=0.338, P<0.001), MAP (r=0.204, P<0.001), and HR (r=0.352, P<0.001) were positively correlated with the week of gestation, and SV was negatively correlated with the week of gestation (r=-0.158, P<0.001). There was no significant correlation between SVR and gestational age (r=-0.051, P=0.258). (2) CO exhibited a positive correlation with maternal height and weight (all P<0.001). The taller and heavier of pregnant women, the higher their CO. A linear relationship was observed between maternal weight and SV, MAP and HR (all P<0.01). As maternal weight increased, SV, MAP and HR showed an upward trend. Furthermore, there was an inverse association between maternal age and SVR (P<0.001). (3) There was a significant nonlinear association observed between TFC and body mass index during pregnancy (P<0.05). Additionally, a nonlinear relationship was found between SVR and MAP in relation to maternal age (all P<0.05). Notably, when the age exceeded 31 years old, there was an evident upward trend observed in both SVR and MAP. Conclusions: The hemodynamic parameters of normal pregnant women are influenced by their height, body weight, and age. It is advisable to maintain a reasonable weight during pregnancy and give birth at an appropriate age.


Assuntos
Débito Cardíaco , Frequência Cardíaca , Hemodinâmica , Volume Sistólico , Resistência Vascular , Humanos , Feminino , Gravidez , Débito Cardíaco/fisiologia , Volume Sistólico/fisiologia , Resistência Vascular/fisiologia , Estudos Prospectivos , Frequência Cardíaca/fisiologia , Idade Gestacional , Valores de Referência , Adulto , Pressão Sanguínea/fisiologia , Pressão Arterial/fisiologia , Peso Corporal
20.
Am J Physiol Lung Cell Mol Physiol ; 324(2): L102-L113, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36511508

RESUMO

Assessment of native cardiac output during extracorporeal circulation is challenging. We assessed a modified Fick principle under conditions such as dead space and shunt in 13 anesthetized swine undergoing centrally cannulated veno-arterial extracorporeal membrane oxygenation (V-A ECMO, 308 measurement periods) therapy. We assumed that the ratio of carbon dioxide elimination (V̇co2) or oxygen uptake (V̇o2) between the membrane and native lung corresponds to the ratio of respective blood flows. Unequal ventilation/perfusion (V̇/Q̇) ratios were corrected towards unity. Pulmonary blood flow was calculated and compared to an ultrasonic flow probe on the pulmonary artery with a bias of 99 mL/min (limits of agreement -542 to 741 mL/min) with blood content V̇o2 and no-shunt, no-dead space conditions, which showed good trending ability (least significant change from 82 to 129 mL). Shunt conditions led to underestimation of native pulmonary blood flow (bias -395, limits of agreement -1,290 to 500 mL/min). Bias and trending further depended on the gas (O2, CO2) and measurement approach (blood content vs. gas phase). Measurements in the gas phase increased the bias (253 [LoA -1,357 to 1,863 mL/min] for expired V̇o2 bias 482 [LoA -760 to 1,724 mL/min] for expired V̇co2) and could be improved by correction of V̇/Q̇ inequalities. Our results show that common assumptions of the Fick principle in two competing circulations give results with adequate accuracy and may offer a clinically applicable tool. Precision depends on specific conditions. This highlights the complexity of gas exchange in membrane lungs and may further deepen the understanding of V-A ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Troca Gasosa Pulmonar , Animais , Suínos , Troca Gasosa Pulmonar/fisiologia , Oxigenação por Membrana Extracorpórea/métodos , Pulmão/irrigação sanguínea , Débito Cardíaco/fisiologia , Artéria Pulmonar , Dióxido de Carbono
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA