Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 534
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
J Biochem Mol Toxicol ; 38(11): e70007, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39400474

RESUMO

Erythrosine, a synthetic food dye, has been controversial due to its potential health risks. This study examines the effect of erythrosine on activity of antioxidative enzymes, oxidative stress indices, DNA damage through comet assay, and histopathological changes on stomach, intestine, and colon over a period of 28 days in rats. Twenty-four rats were randomly divided into four groups (n = 6). The first is the control group and then one each for three doses of erythrosine based on acceptable daily intake (» ADI, ½ ADI, and ADI, 0.1 mg/kg body weight). The results revealed that with increasing dosages the activity of catalase decreased in stomach and intestine but in colon, the catalase activity increased. Superoxide dismutase and glutathione-S-transferase activity decreased in dose-dependent manner in all three tissues. While, in stomach and intestine, the acetylcholinesterase activity showed increment in » ADI dose group and then declined in ½ ADI and ADI dose-administered rats. The oxidative stress indicators showed elevated levels of lipid peroxidation, hydrogen peroxide concentration, and lactate dehydrogenase activity suggesting heightened free radical activity and potential oxidative damage. The comet test was used to evaluate DNA damage, revealing substantial damage in the erythrosine administered groups. Histopathological examination showed inflammatory infiltration and other degenerative changes in gastrointestinal tract, highlighting the dye's adverse effects. The research underscores the need for a comprehensive reevaluation of the safety and toxicity of food dyes like erythrosine, especially considering the inconsistencies in existing studies regarding the dye's safety.


Assuntos
Dano ao DNA , Eritrosina , Estresse Oxidativo , Animais , Estresse Oxidativo/efeitos dos fármacos , Ratos , Masculino , Eritrosina/toxicidade , Ratos Wistar , Corantes de Alimentos/toxicidade , Corantes de Alimentos/efeitos adversos , Trato Gastrointestinal/efeitos dos fármacos , Trato Gastrointestinal/patologia , Trato Gastrointestinal/metabolismo , Acetilcolinesterase/metabolismo , Catalase/metabolismo , Peroxidação de Lipídeos/efeitos dos fármacos , Glutationa Transferase/metabolismo , Superóxido Dismutase/metabolismo
2.
Luminescence ; 39(4): e4725, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38532614

RESUMO

Erythrosine B (EB) is a food colorant antiviral xanthene dye that has many applications as a color additive in pharmaceuticals and cosmetics. Its use as a sensor for spectrofluorimetric and spectrophotometric analysis of amine-based pharmaceuticals renders many advantages because of its availability, low cost, rapid labeling, and high sensitivity. Herein, two fast and sensitive spectrofluorimetric and spectrophotometric methods were established for the estimation of the anti-Parkinson drug, biperiden (BIP) hydrochloride (HCl), in its raw material and tablet forms. The proposed methods depended on the interaction between the phenolic group of EB and the tertiary amino group of the studied analyte to form an ion-pair complex at pH 4 using the Britton Robinson buffer. The spectrofluorimetric method is based on the measurement of the quenching power of BIP HCl on the fluorescence intensity of EB at λex/em = 527.0/550.9 nm. This method was rectilinear over the concentration range of 0.1-1.0 µg/mL with a limit of detection (LOD) = 0.017 µg/mL and a limit of quantification (LOQ) = 0.05 µg/mL. Meanwhile, the colorimetric method involved monitoring the absorbance of the formed ion-pair complex at 555 nm, showing a linearity range of 0.4-5.0 µg/mL with LOD = 0.106 µg/mL and LOQ = 0.322 µg/mL. The proposed methods were assessed for the greenness, indicating the greenness of the developed methods.


Assuntos
Biperideno , Eritrosina , Espectrometria de Fluorescência/métodos , Comprimidos , Limite de Detecção
3.
Luminescence ; 39(5): e4766, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38785095

RESUMO

In this work, two validated approaches were used for estimating hydroxyzine HCl for the first time using resonance Rayleigh scattering (RRS) and spectrofluorimetric techniques. The suggested approaches relied on forming an association complex between hydroxyzine HCl and 2,4,5,7-tetraiodofluorescein (erythrosin B) reagent in an acidic media. The quenching in the fluorescence intensity of 2,4,5,7-tetraiodofluorescein by hydroxyzine at 551.5 nm (excitation = 527.5 nm) was used for determining the studied drug by the spectrofluorimetric technique. The RRS approach is based on amplifying the RRS spectrum at 348 nm upon the interaction of hydroxyzine HCl with 2,4,5,7-tetraiodofluorescein. The spectrofluorimetric methodology and the RRS methodology produced linear results within ranges of 0.15-1.5 µg ml-1 and 0.1-1.2 µg ml-1, respectively. LOD values for these methods were determined to be 0.047 µg ml-1 and 0.033 µg ml-1, respectively. The content of hydroxyzine HCl in its pharmaceutical tablet was estimated using the developed procedures with acceptable recoveries. Additionally, the application of four greenness and whiteness algorithms shows that they are superior to the previously reported method in terms of sustainability, economics, analytical performance, and practicality.


Assuntos
Algoritmos , Hidroxizina , Espectrometria de Fluorescência , Hidroxizina/análise , Hidroxizina/química , Antagonistas dos Receptores Histamínicos/análise , Antagonistas dos Receptores Histamínicos/química , Espalhamento de Radiação , Eritrosina/química , Eritrosina/análise
4.
Luminescence ; 39(4): e4748, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38644515

RESUMO

In an acidic buffered solution, erythrosine B can react with amiodarone to form an association complex, which not only generates great enhancement in resonance Rayleigh scattering (RRS) spectrum of erythrosine B at 346.5 nm but also results in quenching of fluorescence spectra of erythrosine B at λemission = 550.4 nm/λexcitation = 528.5 nm. In addition, the formed erythrosine B-amiodarone complex produces a new absorbance peak at 555 nm. The spectral characteristics of the RRS, absorbance, and fluorescence spectra, as well as the optimum analytical conditions, were studied and investigated. As a result, new spectroscopic methods were developed to determine amiodarone by utilizing erythrosine B as a probe. Moreover, the ICH guidelines were used to validate the developed RRS, photometric, and fluorimetric methods. The enhancements in the absorbance and the RRS intensity and the decrease in the fluorescence intensity of the used probe were proportional to the concentration of amiodarone in ranges of 2.5-20.0, 0.2-2.5, and 0.25-1.75 µg/mL, respectively. Furthermore, limit of detection values were 0.52 ng/mL for the spectrophotometric method, 0.051 µg/mL for the RRS method, and 0.075 µg/mL for the fluorimetric method. Moreover, with good recoveries, the developed spectroscopic procedures were applied to analyze amiodarone in its commercial tablets.


Assuntos
Amiodarona , Eritrosina , Espectrometria de Fluorescência , Amiodarona/análise , Amiodarona/química , Eritrosina/química , Eritrosina/análise , Antiarrítmicos/análise , Antiarrítmicos/química , Estrutura Molecular
5.
Luminescence ; 39(5): e4777, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38785072

RESUMO

This study introduces a practical and cost-effective method for tracking diltiazem (DLZ) analytically. It utilizes a fluorimetric approach that relies on the modulation of fluorescence intensity of a dye called erythrosine B. Through a one-pot experiment performed in an acidic environment, a complex is rapidly formed between DLZ and erythrosine B. By observing the decrease in erythrosine B emission, a linear calibration plot is established, enabling the detection and quantification of DLZ concentrations ranging from 40 to 850 ng/ml. The estimated limits of detection and quantitation were 10.5 and 32.1 ng/ml, respectively. The variables affecting the DLZ-dye complex system were carefully adjusted. The validity of the approach was confirmed through a thorough evaluation based on the criteria set by ICH guidelines. The accuracy and precision of the methodology were evaluated, and the standard deviation and relative standard deviation were below 2. The strategy was successfully employed to analyze DLZ in tablets and capsules, and no significant variation between the proposed and reported methods as the values of the estimated t-test and F-test at five determinations were below 2.306 and 6.338, respectively. Notably, the method adheres to the principle of green chemistry by utilizing distilled water as the dispersing medium.


Assuntos
Diltiazem , Eritrosina , Diltiazem/análise , Diltiazem/química , Eritrosina/química , Eritrosina/análise , Espectrometria de Fluorescência , Comprimidos/análise , Concentração de Íons de Hidrogênio , Limite de Detecção , Cápsulas/química , Corantes Fluorescentes/química , Formas de Dosagem
6.
Luminescence ; 39(7): e4845, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39054772

RESUMO

A recently developed antipsychotic drug, lurasidone, was determined using a simple, sensitive, and eco-friendly spectrofluorimetric approach. The suggested approach was based on the quantifiable quenching impact of lurasidone on the inherent fluorescence of erythrosine B in an acidic environment employing a Teorell-Stenhagen buffer (pH 4). Following excitation at 530 nm, the quenching of erythrosine B fluorescence was monitored at 552 nm. The system variables were systematically optimized to enhance the formation of the lurasidone-erythrosine B ion pair for analytical purposes. A linear calibration graph was built in the range of 20-600 ng mL-1 with 0.9998 as a coefficient of correlation. The quantitation and detection limits were 13.5 and 4.5 ng/mL, respectively. The analytical validity of the designed approach was assessed with respect to International Council on Harmonization (ICH) guiding principles. The proposed methodology was employed with high recoveries for assessing lurasidone in bulk powder and its therapeutic tablet dosage form. Additionally, the uniformity of tablet formulations was tested using the developed approach. Finally, the established approach was assessed for its greenness using various tools.


Assuntos
Eritrosina , Cloridrato de Lurasidona , Espectrometria de Fluorescência , Cloridrato de Lurasidona/química , Cloridrato de Lurasidona/análise , Eritrosina/química , Eletricidade Estática , Concentração de Íons de Hidrogênio , Comprimidos/análise , Antipsicóticos/química , Corantes Fluorescentes/química , Limite de Detecção
7.
J Environ Manage ; 350: 119545, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37995482

RESUMO

A novel octahedral distorted coordination complex was formed from a copper transition metal with a bidentate ligand (1,10-Phenanthroline) and characterized by Ultraviolet-visible spectroscopy, Ultraviolet-visible diffuse reflectance spectroscopy, Fourier-transform infrared spectroscopy, Brunauer-Emmett-Teller, Field emission scanning electron microscopy, and Single-crystal X-ray diffraction. The Hirshfeld surface and fingerprint plot analyses were conducted to determine the interactions between atoms in the Cu(II) complex. DFT calculations showed that the central copper ion and its coordinated atoms have an octahedral geometry. The Molecular electrostatic potential (MEP) map indicated that the copper (II) complex is an electrophilic compound that can interact with negatively charged macromolecules. The HOMO-LUMO analysis demonstrated the π nature charge transfer from acetate to phenanthroline. The band gap of [Cu(phen)2(OAc)]·PF6 photocatalyst was estimated to be 2.88 eV, confirming that this complex is suitable for environmental remediation. The photocatalytic degradation of erythrosine, malachite green, methylene blue, and Eriochrome Black T as model organic pollutants using the prepared complex was investigated under visible light. The [Cu(phen)2(OAc)]·PF6 photocatalyst exhibited degradation 94.7, 90.1, 82.7, and 74.3 % of malachite green, methylene blue, erythrosine, and Eriochrome Black T, respectively, under visible illumination within 70 min. The results from the Langmuir-Hinshelwood kinetic analysis demonstrated that the Cu(II) complex has a higher efficiency for the degradation of cationic pollutants than the anionic ones. This was attributed to surface charge attraction between photocatalyst and cationic dyes promoting removal efficiency. The reusability test indicated that the photocatalyst could be utilized in seven consecutive photocatalytic degradation cycles with an insignificant decrease in efficiency.


Assuntos
Cobre , Poluentes Ambientais , Cobre/química , Azul de Metileno/química , Cinética , Eritrosina , Luz , Corantes/química , Catálise
8.
Molecules ; 29(16)2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39202995

RESUMO

Resistant biofilms formed by Staphylococcus aureus on medical devices pose a constant medical threat. A promising alternative to tackle this problem is photodynamic inactivation (PDI). This study focuses on a polyurethane (PU) material with an antimicrobial surface consisting of a composite based on silicate, polycation, and erythrosine B (EryB). The composite was characterized using X-ray diffraction and spectroscopy methods. Anti-biofilm effectiveness was determined after PDI by calculation of CFU mL-1. The liquid PU precursors penetrated a thin silicate film resulting in effective binding of the PU/silicate composite and the PU bulk phases. The incorporation of EryB into the composite matrix did not significantly alter the spectral properties or photoactivity of the dye. A green LED lamp and laser were used for PDI, while irradiation was performed for different periods. Preliminary experiments with EryB solutions on planktonic cells and biofilms optimized the conditions for PDI on the nanocomposite materials. Significant eradication of S. aureus biofilm on the composite surface was achieved by irradiation with an LED lamp and laser for 1.5 h and 10 min, respectively, resulting in a 10,000-fold reduction in biofilm growth. These results demonstrate potential for the development of antimicrobial polymer surfaces for modification of medical materials and devices.


Assuntos
Biofilmes , Eritrosina , Nanocompostos , Staphylococcus aureus , Biofilmes/efeitos dos fármacos , Nanocompostos/química , Staphylococcus aureus/efeitos dos fármacos , Eritrosina/farmacologia , Eritrosina/química , Poliuretanos/química , Poliuretanos/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/química , Silicatos/química , Silicatos/farmacologia , Fotoquimioterapia/métodos , Polieletrólitos
9.
J Org Chem ; 88(13): 8992-9003, 2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37302135

RESUMO

A visible-light-induced efficient methodology has been developed for the C-H selenylation of pyrazolo[1,5-a]pyrimidine derivatives employing erythrosine B as the photocatalyst. This is the first report on the regioselective selenylation of pyrazolo[1,5-a]pyrimidines. The efficiency of this methodology for the selenylation of different electron-rich heterocycles like pyrazole, indole, imidazo[1,2-a]pyridine, imidazo[2,1-b]thiazole, and 4-(phenylamino)-2H-chromen-2-one has been also demonstrated. The exploration of erythrosine B as a photocatalyst with a simple and mild procedure, wide substrate scope, and practical applicability and the employment of eco-friendly energy, oxidant, and solvent are the attractive characteristics of this methodology.


Assuntos
Eritrosina , Pirimidinas , Pirimidinas/farmacologia , Solventes
10.
Environ Sci Technol ; 57(32): 12105-12116, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37531556

RESUMO

Intracellular antibiotic resistance genes (iARGs) constitute the important part of wastewater ARGs and need to be efficiently removed. However, due to the dual protection of intracellular DNA by bacterial membranes and the cytoplasm, present disinfection technologies are largely inefficient in iARG degradation. Herein, we for the first time found that erythrosine (ERY, an edible dye) could efficiently degrade iARGs by producing abundant 1O2 under visible light. Seven log antibiotic-resistant bacteria were inactivated within only 1.5 min, and 6 log iARGs were completely degraded within 40 min by photosensitized ERY (5.0 mg/L). A linear relationship was established between ARG degradation rate constants and 1O2 concentrations in the ERY photosensitizing system. Surprisingly, a 3.2-fold faster degradation of iARGs than extracellular ARGs was observed, which was attributed to the unique indirect oxidation of iARGs induced by 1O2. Furthermore, ERY photosensitizing was effective for iARG degradation in real wastewater and other photosensitizers (including Rose Bengal and Phloxine B) of high 1O2 yields could also achieve efficient iARG degradation. The findings increase our knowledge of the iARG degradation preference by 1O2 and provide a new strategy of developing technologies with high 1O2 yield, like ERY photosensitizing, for efficient iARG removal.


Assuntos
Antibacterianos , Eritrosina , Antibacterianos/farmacologia , Eritrosina/farmacologia , Águas Residuárias , Resistência Microbiana a Medicamentos/genética , Bactérias/genética , Genes Bacterianos
11.
J Clin Periodontol ; 50(3): 331-338, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36345833

RESUMO

AIM: To develop a simple and reproducible method for semi-automated planimetric quantification of dental plaque. MATERIALS AND METHODS: Plaque from 20 healthy volunteers was disclosed using erythrosine, and fluorescence images of the first incisors, first premolars, and first molars were recorded after 1, 7, and 14 days of de novo plaque formation. The planimetric plaque index (PPI) was determined using a semi-automated threshold-based image segmentation algorithm and compared with manually determined PPI and the Turesky modification of the Quigley-Hein plaque index (TM-QHPI). The decrease of tooth autofluorescence in plaque-covered areas was quantified as an index of plaque thickness (TI). Data were analysed by analysis of variance (ANOVA) and Pearson correlations. RESULTS: The high contrast between teeth, disclosed plaque, and soft tissues in fluorescence images allowed for a fast threshold-based image segmentation. Semi-automated PPI is strongly correlated with manual planimetry (r = 0.92; p < .001) and TM-QHPI recordings (r = 0.88; p < .001), and may exhibit a higher discriminatory power than TM-QHPI due to its continuous scale. TI values corresponded to optically perceived plaque thickness, and no differences were observed over time (p > .05, ANOVA). CONCLUSIONS: The proposed semi-automated planimetric analysis based on fluorescence images is a simple and efficient method for dental plaque quantification in multiple images with reduced human input.


Assuntos
Placa Dentária , Humanos , Placa Dentária/diagnóstico por imagem , Reprodutibilidade dos Testes , Índice de Placa Dentária , Incisivo , Eritrosina
12.
Ecotoxicol Environ Saf ; 266: 115578, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37856984

RESUMO

In this study, a green approach was used to synthesize SmMnO3 magnetic nanoparticles via the auto combustion method, where pomegranate juice was utilized as a natural fuel. The concentration of fuel was varied to investigate its effect on the purity and morphology of SmMnO3 nanoparticles. The physiochemical properties of the synthesized nanoparticles, including crystal structures, morphology, optical, and magnetic properties, were investigated using X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), Fourier-Transform Infrared Spectroscopy (FTIR), Vibrating Sample Magnetometer (VSM), Diffuse Reflectance Spectroscopy (DRS), X-ray fluorescence (XRF) and Brunauer-Emmett-Teller (BET). The band gap of the as-synthesized nanoparticles was determined to be 1.8 eV, indicating their potential as a photocatalyst. The photocatalytic activity of SmMnO3 nanoparticles was evaluated against Methyl violet and Erythrosine, and the mechanism of photocatalyst was determined using EDTA, benzoic acid, and benzoquinone as scavengers. Photocatalytic activity was studied in both UV and visible light, and it was found that the maximum degradation (94%) was related to the degradation of Erythrosine (10 ppm) in the presence of visible light. The stability test of SmMnO3 performed and confirmed the stability of nanoparticles after 5 cycles. The results suggest that SmMnO3 nanoparticles synthesized via the green auto combustion method using pomegranate juice as a natural fuel can serve as a promising photocatalyst for the degradation of organic pollutants in the environment. Further studies can be conducted to investigate their potential in other applications.


Assuntos
Poluentes Ambientais , Nanopartículas , Poluentes da Água , Samário , Eritrosina , Luz , Água , Catálise
13.
Luminescence ; 38(3): 291-301, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36702460

RESUMO

Novel, selective, facile, and precise spectroscopic approaches were validated to determine nilotinib hydrochloride, a tyrosine kinase inhibitor used to treat patients with chronic myeloid leukemia. These approaches depend on the reaction of the tertiary amine group of nilotinib with erythrosine B in the Britton-Robinson buffer at pH 4. Method I, depends on measuring the absorbance of the formed complex at 551 nm. The absorbance concentration plot showed linearity over the concentration range of 1.0 to 9.0 µg/ml. Method II, involved the measurement of the quenching of the native fluorescence of erythrosine B by adding nilotinib in an acidic medium. The fluorescence quenching of erythrosine B was measured at 549 nm after excitation at 528 nm. This approach showed excellent linearity in the concentration range of 0.04 to 0.7 µg/ml. The limit of detection values for Method I and Method II were 0.225 and 0.008 µg/ml, respectively, while the limit of quantitation values for Method I and Method II were 0.68 and 0.026 µg/ml, respectively. To get the optimal conditions, factors that may affect the formation of the ion-pairing complex were thoroughly examined. The two approaches were carefully validated following the International Conference of Harmonization (ICH Q2R1) guidelines. Statistical assessment of the results achieved using the suggested and previously published comparison approaches showed no significant difference. The approaches were successful in determining nilotinib in a pharmaceutical dosage form as well as spiked human plasma samples. The eco-friendly properties of the methods were evaluated by three different tools.


Assuntos
Eritrosina , Humanos , Pós , Espectrometria de Fluorescência/métodos , Eritrosina/química , Cápsulas
14.
Luminescence ; 38(12): 2073-2085, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37747151

RESUMO

Sunitinib is a tyrosine kinase inhibitor used for the treatment of renal cell carcinoma and gastrointestinal stromal tumors. In this study, two spectroscopic methods, spectrofluorometric and spectrophotometric, were utilized to quantify sunitinib in different matrices. In method I, the native fluorescence of erythrosine B was quenched by forming ion-pair complex with increasing quantities of sunitinib. This approach was utilized for measuring sunitinib in its dosage forms and spiked plasma. After excitation at 528 nm, the quenching of fluorescence is linearly related to the concentration across the range of 0.05-0.5 µg mL-1 at 550 nm in Britton-Robinson buffer (pH 4.0), with a correlation value of 0.9999 and a high level of sensitivity with detection limit down to 10 ng mL-1 . Method II relies on spectrophotometric measurements of the produced complex at 550 nm across a range of 0.5-10.0 µg mL-1 , with good correlation value of 0.9999. This method has a detection limit down to 0.16 µg mL-1 . The proposed methodologies were validated according to International Conference on Harmonization (ICH) guidelines with satisfactory results. The stoichiometry of the reaction was determined through the application of Job's method, while the mechanism of quenching was investigated by employing the Stern-Volmer plot. The designated methods were used to estimate sunitinib in its capsules and in spiked human plasma. Additionally, the statistical analysis of the data revealed no substantial differences when compared to previous reported spectroscopic method. Green assessment tools provide further details about the eco-friendly nature of the methods.


Assuntos
Eritrosina , Corantes de Alimentos , Humanos , Eritrosina/química , Sunitinibe , Composição de Medicamentos , Espectrometria de Fluorescência/métodos
15.
Luminescence ; 38(10): 1836-1843, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37555794

RESUMO

Naftidrofuryl is a vasodilator medication used for treating cerebral and peripheral vascular diseases. In this study, two spectroscopical techniques, spectrofluorimetric and resonance Rayleigh scattering (RRS), were utilized to quantify naftidrofuryl in its pharmaceutical samples. The developed methodologies in this study rely on a facile process of forming an association complex between erythrosine B reagent and naftidrofuryl under acidic conditions. The fluorimetric assay is based on the ability of naftidrofuryl to quench and decrease the native fluorescence intensity of the reagent when measured at λ emis . = 550 nm ( λ excit . = 526 nm). Under similar reaction conditions, the RRS method relies on the observed amplification in the RRS spectrum of the reagent at a wavelength of 577 nm following its interaction with naftidrofuryl. The methods exhibited linearity within the ranges 0.2-1.6 µg/ml (r2  = 0.999) and 0.1-1.4 µg/ml (r2  = 0.9994), with limit of quantitation values of 0.146 and 0.099 µg/ml, and limit of detection values of 0.048 and 0.032 µg/ml, for the fluorometric and the RRS methods, respectively. Moreover, the quenching between the dye and naftidrofuryl was studied using Stern-Volmer analysis, and the methodologies were experimentally optimized and validated. Additionally, acceptable recoveries were achieved when the procedures were applied to determine naftidrofuryl in pharmaceutical samples.


Assuntos
Eritrosina , Nafronil , Nafronil/análise , Espectrometria de Fluorescência/métodos , Espalhamento de Radiação , Preparações Farmacêuticas
16.
Luminescence ; 38(9): 1583-1590, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37325939

RESUMO

A spectrofluorimetric approach that is sensitive, simple, validated, and cost-effective has been proposed for the estimation of amlodipine (AML) and perindopril (PER) in their bulk powders, pharmaceutical formulations, and spiked human plasma. The recommended approach utilized the quantitative quenching effect of the two cited drugs on the fluorescence intensity of erythrosine B, as a result of complex binary reactions among each drug with erythrosine B at pH 3.5 (Teorell and Stenhagen buffer). The quenching of erythrosine B fluorescence was recorded at 554 nm after excitation at 527 nm. The calibration curve was detected in the range 0.25-3.0 µg ml-1 , with a correlation coefficient of 0.9996 for AML, and 0.1-1.5 µg ml-1 , with a correlation coefficient of 0.9996 for PER. The established spectrofluorimetric approach was validated for the estimation of the cited drugs with high sensitivity regarding International Council on Harmonization guidelines. Therefore, the established approach could be utilized for quality control of the cited drugs in their pharmaceutical formulations.


Assuntos
Anlodipino , Leucemia Mieloide Aguda , Humanos , Perindopril , Eritrosina , Espectrometria de Fluorescência , Preparações Farmacêuticas
17.
Lasers Med Sci ; 38(1): 260, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37946038

RESUMO

This study aimed to investigate the photodynamic effects of curcumin, nanomicelle curcumin, and erythrosine on Lactobacillus casei (L. casei). Various concentrations of curcumin (1.5 g/L, 3 g/L), nano-curcumin (3 g/L), and erythrosine (100 µM/L, 250 µM/L) were tested either alone or combined with light irradiation (PDT effect) against L. casei in planktonic and biofilm cultures. The light was emitted from a light-emitting diode (LED) with a central wavelength of 450 nm. A 0.12% chlorhexidine digluconate (CHX) solution served as the positive control, and a solution containing neither photosensitizer nor light was the negative control group. The number of viable microorganisms was determined using serial dilution. There was a significant difference in the viability of L. casei in both planktonic and biofilm forms (P < 0.05). In the planktonic culture, the antibacterial effects of CHX and PDT groups with curcumin 3 g/L and erythrosine 250 µM/L were significantly greater than the other groups (P < 0.05). For L. casei biofilms, the greatest toxic effects were observed in CHX and PDT groups with curcumin 3 g/L, erythrosine 250 µmol/L, erythrosine 100 µmol/L, and nanomicelle curcumin 3 g/L, with a significant difference to other groups (P < 0.05). The antibacterial effects of all photosensitizers (except erythrosine 250 µmol/L at planktonic culture) enhanced significantly when combined with light irradiation (P < 0.05). PDT with curcumin 3 g/L or erythrosine 250 µmol/L produced comparable results to CHX against L. casei at both planktonic and biofilm cultures. Alternatively, PDT with erythrosine 100 µmol/L or nanomicelle curcumin 3 g/L could be suggested to kill L. casei biofilms.


Assuntos
Anti-Infecciosos , Curcumina , Lacticaseibacillus casei , Fotoquimioterapia , Eritrosina/farmacologia , Fotoquimioterapia/métodos , Curcumina/farmacologia , Streptococcus mutans/efeitos da radiação , Fármacos Fotossensibilizantes/farmacologia , Anti-Infecciosos/farmacologia , Biofilmes , Antibacterianos/farmacologia
18.
Luminescence ; 37(10): 1785-1792, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35922904

RESUMO

Two facile spectroscopic methodologies were designed for estimating trospium chloride (TPM) in raw material and tablets with high operational reliability and selectivity. The methods were based on using erythrosine B (EB) as a spectroscopic tool for ion-pair complex formation with the drug. In a mild acidic medium of Britton Robinson buffer (pH 4.0), the ionized hydroxyl group in the reagent interacted with the ionized amine in the studied drug. Method I was based on the spectrophotometric measuring of the absorbance of the reaction product at 557 nm. Method II was based on spectrofluorimetric measurement of the quenching effect of TPM on the inherent fluorescence of EB at 550 nm (λex. = 528 nm). The two methods showed linearity through ranges 1.0-10.0 and 0.5-10.0 µg/ml for Methods I and II, respectively. The suggested methods were exploited for analyzing TPM in Trospamexin® tablets and showed good applicability. The designed systems were validated as per International Conference on Harmonization guidelines. Experimental conditions were modulated to obtain the best sensitivities. The quenching mechanism was investigated and the quenching constant was computed relying on the Stern-Volmer equation. Environmental impact was appraised using novel metric green tools, GABI, and AGREE. The suggested systems excelled over other reported methods in terms of greenness, sensitivity, and cost-effectiveness.


Assuntos
Aminas , Eritrosina , Benzilatos , Eritrosina/química , Nortropanos , Reprodutibilidade dos Testes , Espectrometria de Fluorescência/métodos , Comprimidos
19.
Luminescence ; 37(7): 1215-1222, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35582967

RESUMO

The interaction of venlafaxine hydrochloride (VLX) with erythrosine B was investigated using a resonance Rayleigh scattering (RRS) spectroscopic technique. In acetate buffer (pH 3.4), erythrosine B reacted with VLX to form a 1:1 ion-pair complex with concomitant enhancement in RRS intensity that was measured at 330 nm. In addition, the stability constant and the change in free energy of the reaction were estimated. Based on this interaction a new method was developed for a sensitive VLX analysis using erythrosine B as a probe. The results indicated that this method had good selectivity in the presence of coexisting compounds. The scattering intensity (ΔIRRS ) was linearly dependent on VLX concentration over the range 0.04-1.0 µg ml-1 with a determination coefficient (r) of 0.9998. The limit of detection and limit of quantitation were 0.01 and 0.03 µg ml-1 , respectively. This method could be suitably used for analysis of VLX in pharmaceutical capsules and human plasma.


Assuntos
Eritrosina , Eritrosina/química , Humanos , Preparações Farmacêuticas , Espalhamento de Radiação , Análise Espectral/métodos , Cloridrato de Venlafaxina
20.
Molecules ; 27(21)2022 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-36364348

RESUMO

We present a new photoswitchable spin label for light-induced pulsed electron paramagnetic resonance dipolar spectroscopy (LiPDS), the photoexcited triplet state of erythrosin B (EB), which is ideal for biological applications. With this label, we perform an in-depth study of the orientational effects in dipolar traces acquired using the refocused laser-induced magnetic dipole technique to obtain information on the distance and relative orientation between the EB and nitroxide labels in a rigid model peptide, in good agreement with density functional theory predictions. Additionally, we show that these orientational effects can be averaged to enable an orientation-independent analysis to determine the distance distribution. Furthermore, we demonstrate the feasibility of these experiments above liquid nitrogen temperatures, removing the need for expensive liquid helium or cryogen-free cryostats. The variety of choices in photoswitchable spin labels and the affordability of the experiments are critical for LiPDS to become a widespread methodology in structural biology.


Assuntos
Eritrosina , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Marcadores de Spin , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA