Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.211
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Am Heart J ; 274: 95-101, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38677503

RESUMO

BACKGROUND: Previous reports reveal inconsistent findings of right ventricular (RV) changes following pregnancy in subjects with repaired tetralogy of Fallot (rTOF). METHODS: A two-center, retrospective cohort study which included women with rTOF who completed pregnancy that were matched to nulliparous women with rTOF by age at the time of baseline cardiac magnetic resonance (CMR), RV ejection fraction (RVEF), and indexed RV end-diastolic volume (RVEDVi). Pre-pregnancy and postpartum cardiac magnetic resonance (CMR) were analyzed and compared to sequential CMR of nulliparous subjects with rTOF. RESULTS: Thirty-six women with rTOF who completed pregnancy were matched to 72 nulliparous women with rTOF. Over a mean period of 3.1 years for the pregnancy group and 2.7 years for the comparison group, there was no significant change in the RVEDVi, RVEF, RV mass, pulmonary regurgitation severity, left ventricular (LV) volumes, LV ejection fraction (LVEF), or LV mass when comparing the baseline CMR and the follow-up CMR in either of the groups. There was a slight increase in RV indexed end-systolic volume (RVESVi) when comparing the baseline CMR and the follow-up CMR in the pregnancy group (68.93, SD 23.34 ml/m2 at baseline vs. 72.97, SD 25.24 mL/m2 at follow-up, P = .028). Using a mixed effects model for CMR parameters change over time; when adjusted for time between baseline and follow-up CMR there was no significant difference in rate of change between the pregnancy and comparison groups. CONCLUSIONS: Most ventricular remodeling parameters measured by CMR did not significantly change in subjects with rTOF who completed pregnancy or in nulliparous subjects with rTOF. In the pregnancy group, RVESVi is larger in those individuals who have undergone pregnancy without a significant change in ventricular function. These patients should be followed longitudinally to determine the long-term ventricular and clinical effects of pregnancy.


Assuntos
Imagem Cinética por Ressonância Magnética , Volume Sistólico , Tetralogia de Fallot , Humanos , Feminino , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Gravidez , Estudos Retrospectivos , Adulto , Volume Sistólico/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Complicações Cardiovasculares na Gravidez/fisiopatologia , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/métodos , Seguimentos , Adulto Jovem
2.
Am Heart J ; 271: 148-155, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38430992

RESUMO

BACKGROUND: Mortality after ST-segment elevation myocardial infarction (STEMI) is increased in patients with hypertension. The mechanisms underlying this association are uncertain. We sought to investigate whether patients with STEMI and prior hypertension have greater microvascular obstruction (MVO) and infarct size (IS) compared with those without hypertension. METHODS: We pooled individual patient data from 7 randomized trials of patients with STEMI undergoing primary percutaneous coronary intervention (PCI) in whom cardiac magnetic resonance imaging was performed within 1 month after reperfusion. The associations between hypertension and MVO, IS, and mortality were assessed in multivariable adjusted models. RESULTS: Among 2174 patients (61.3 ± 12.6 years, 76% male), 1196 (55.0%) had hypertension. Patients with hypertension were older, more frequently diabetic and had more extensive coronary artery disease than those without hypertension. MVO and IS measured as percent LV mass were not significantly different in patients with and without hypertension (adjusted differences 0.1, 95% CI -0.3 to 0.6, P = .61 and -0.2, 95% CI -1.5 to 1.2, P = .80, respectively). Hypertension was associated with a higher unadjusted risk of 1-year death (hazard ratio [HR] 2.28, 95% CI 1.44-3.60, P < .001), but was not independently associated with higher mortality after multivariable adjustment (adjusted HR 1.04, 95% CI 0.60-1.79, P = .90). CONCLUSION: In this large-scale individual patient data pooled analysis, hypertension was not associated with larger IS or MVO after primary PCI for STEMI.


Assuntos
Hipertensão , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Intervenção Coronária Percutânea/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Hipertensão/complicações , Imagem Cinética por Ressonância Magnética/métodos , Idoso , Microcirculação , Imageamento por Ressonância Magnética/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
3.
Magn Reson Med ; 91(1): 266-279, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37799087

RESUMO

PURPOSE: Interactive cardiac MRI is used for fast scan planning and MR-guided interventions. However, the requirement for real-time acquisition and near-real-time visualization constrains the achievable spatio-temporal resolution. This study aims to improve interactive imaging resolution through optimization of undersampled spiral sampling and leveraging of deep learning for low-latency reconstruction (deep artifact suppression). METHODS: A variable density spiral trajectory was parametrized and optimized via HyperBand to provide the best candidate trajectory for rapid deep artifact suppression. Training data consisted of 692 breath-held CINEs. The developed interactive sequence was tested in simulations and prospectively in 13 subjects (10 for image evaluation, 2 during catheterization, 1 during exercise). In the prospective study, the optimized framework-HyperSLICE- was compared with conventional Cartesian real-time and breath-hold CINE imaging in terms quantitative and qualitative image metrics. Statistical differences were tested using Friedman chi-squared tests with post hoc Nemenyi test (p < 0.05). RESULTS: In simulations the normalized RMS error, peak SNR, structural similarity, and Laplacian energy were all statistically significantly higher using optimized spiral compared to radial and uniform spiral sampling, particularly after scan plan changes (structural similarity: 0.71 vs. 0.45 and 0.43). Prospectively, HyperSLICE enabled a higher spatial and temporal resolution than conventional Cartesian real-time imaging. The pipeline was demonstrated in patients during catheter pull back, showing sufficiently fast reconstruction for interactive imaging. CONCLUSION: HyperSLICE enables high spatial and temporal resolution interactive imaging. Optimizing the spiral sampling enabled better overall image quality and superior handling of image transitions compared with radial and uniform spiral trajectories.


Assuntos
Processamento de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética , Suspensão da Respiração
4.
Magn Reson Med ; 92(4): 1484-1495, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38725423

RESUMO

PURPOSE: To develop and evaluate a phase unwrapping method for cine phase contrast MRI based on graph cuts. METHODS: A proposed Iterative Graph Cuts method was evaluated in 10 cardiac patients with two-dimensional flow quantification which was repeated at low venc settings to provoke wrapping. The images were also unwrapped by a path-following method (ROMEO), and a Laplacian-based method (LP). Net flow was quantified using semi-automatic vessel segmentation. High venc images were also wrapped retrospectively to asses the residual amount of wrapped voxels. RESULTS: The absolute net flow error after unwrapping at venc = 100 cm/s was 1.8 mL, which was 0.83 mL smaller than for LP. The repeatability error at high venc without unwrapping was 2.5 mL. The error at venc = 50 cm/s was 7.5 mL, which was 8.2 mL smaller than for ROMEO and 5.7 mL smaller than for LP. For retrospectively wrapped images with synthetic venc of 100/50/25 cm/s, the residual amount of wrapped voxels was 0.00/0.12/0.79%, which was 0.09/0.26/8.0 percentage points smaller than for LP. With synthetic venc of 25 cm/s, omitting magnitude information resulted in 3.2 percentage points more wrapped voxels, and only spatial/temporal unwrapping resulted in 4.6/21 percentage points more wrapped voxels compared to spatiotemporal unwrapping. CONCLUSION: Iterative Graph Cuts enables unwrapping of cine phase contrast MRI with very small errors, except for at extreme blood velocities, with equal or better performance compared to ROMEO and LP. The use of magnitude information and spatiotemporal unwrapping is recommended.


Assuntos
Algoritmos , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Feminino , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade
5.
Magn Reson Med ; 91(4): 1637-1644, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38041477

RESUMO

PURPOSE: Guidelines recommend measuring myocardial extracellular volume (ECV) using T1 -mapping before and 10-30 min after contrast agent administration. Data are then analyzed using a linear model (LM), which assumes fast water exchange (WX) between the ECV and cardiomyocytes. We investigated whether limited WX influences ECV measurements in patients with severe aortic stenosis (AS). METHODS: Twenty-five patients with severe AS and 5 healthy controls were recruited. T1 measurements were made on a 3 T Siemens system using a multiparametric saturation-recovery single-shot acquisition (a) before contrast; (b) 4 min post 0.05 mmol/kg gadobutrol; and (c) 4 min, (d) 10 min, and (e) 30 min after an additional gadobutrol dose (0.1 mmol/kg). Three LM-based ECV estimates, made using paired T1 measurements (a and b), (a and d), and (a and e), were compared to ECV estimates made using all 5 T1 measurements and a two-site exchange model (2SXM) accounting for WX. RESULTS: Median (range) ECV estimated using the 2SXM model was 25% (21%-39%) for patients and 26% (22%-29%) for controls. ECV estimated in patients using the LM at 10 min following a cumulative contrast dose of 0.15 mmol/kg was 21% (17%-32%) and increased significantly to 22% (19%-35%) at 30 min (p = 0.0001). ECV estimated using the LM was highest following low dose gadobutrol, 25% (19%-38%). CONCLUSION: Current guidelines on contrast agent dose for ECV measurements may lead to underestimated ECV in patients with severe AS because of limited WX. Use of a lower contrast agent dose may mitigate this effect.


Assuntos
Estenose da Valva Aórtica , Compostos Organometálicos , Humanos , Meios de Contraste , Miocárdio , Valor Preditivo dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética
6.
Magn Reson Med ; 92(3): 1064-1078, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38726772

RESUMO

PURPOSE: This study aims to develop and evaluate a novel cardiovascular MR sequence, MyoFold, designed for the simultaneous quantifications of myocardial tissue composition and wall motion. METHODS: MyoFold is designed as a 2D single breathing-holding sequence, integrating joint T1/T2 mapping and cine imaging. The sequence uses a 2-fold accelerated balanced SSFP (bSSFP) for data readout and incorporates electrocardiogram synchronization to align with the cardiac cycle. MyoFold initially acquires six single-shot inversion-recovery images, completed during the diastole of six successive heartbeats. T2 preparation (T2-prep) is applied to introduce T2 weightings for the last three images. Subsequently, over the following six heartbeats, segmented bSSFP is performed for the movie of the entire cardiac cycle, synchronized with an electrocardiogram. A neural network trained using numerical simulations of MyoFold is used for T1 and T2 calculations. MyoFold was validated through phantom and in vivo experiments, with comparisons made against MOLLI, SASHA, T2-prep bSSFP, and the conventional cine. RESULTS: In phantom studies, MyoFold exhibited a 10% overestimation in T1 measurements, whereas T2 measurements demonstrated high accuracy. In vivo experiments revealed that MyoFold T1 had comparable accuracy to SASHA and precision similar to MOLLI. MyoFold demonstrated good agreement with T2-prep bSSFP in myocardial T2 measurements. No significant differences were observed in the quantification of left-ventricle wall thickness and function between MyoFold and the conventional cine. CONCLUSION: MyoFold presents as a rapid, simple, and multitasking approach for quantitative cardiovascular MR examinations, offering simultaneous assessment of tissue composition and wall motion. The sequence's multitasking capabilities make it a promising tool for comprehensive cardiac evaluations in clinical settings.


Assuntos
Coração , Imagem Cinética por Ressonância Magnética , Imagens de Fantasmas , Adulto , Feminino , Humanos , Masculino , Algoritmos , Eletrocardiografia , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio , Reprodutibilidade dos Testes
7.
Magn Reson Med ; 92(5): 1838-1850, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38817154

RESUMO

PURPOSE: Tricuspid valve flow velocities are challenging to measure with cardiovascular MR, as the rapidly moving valvular plane prohibits direct flow evaluation, but they are vitally important to diastolic function evaluation. We developed an automated valve-tracking 2D method for measuring flow through the dynamic tricuspid valve. METHODS: Nine healthy subjects and 2 patients were imaged. The approach uses a previously trained deep learning network, TVnet, to automatically track the tricuspid valve plane from long-axis cine images. Subsequently, the tracking information is used to acquire 2D phase contrast (PC) with a dynamic (moving) acquisition plane that tracks the valve. Direct diastolic net flows evaluated from the dynamic PC sequence were compared with flows from 2D-PC scans acquired in a static slice localized at the end-systolic valve position, and also ventricular stroke volumes (SVs) using both planimetry and 2D PC of the great vessels. RESULTS: The mean tricuspid valve systolic excursion was 17.8 ± 2.5 mm. The 2D valve-tracking PC net diastolic flow showed excellent correlation with SV by right-ventricle planimetry (bias ± 1.96 SD = -0.2 ± 10.4 mL, intraclass correlation coefficient [ICC] = 0.92) and aortic PC (-1.0 ± 13.8 mL, ICC = 0.87). In comparison, static tricuspid valve 2D PC also showed a strong correlation but had greater bias (p = 0.01) versus the right-ventricle SV (10.6 ± 16.1 mL, ICC = 0.61). In most (8 of 9) healthy subjects, trace regurgitation was measured at begin-systole. In one patient, valve-tracking PC displayed a high-velocity jet (380 cm/s) with maximal velocity agreeing with echocardiography. CONCLUSION: Automated valve-tracking 2D PC is a feasible route toward evaluation of tricuspid regurgitant velocities, potentially solving a major clinical challenge.


Assuntos
Aprendizado Profundo , Imagem Cinética por Ressonância Magnética , Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Masculino , Feminino , Adulto , Imagem Cinética por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Pessoa de Meia-Idade , Diástole , Processamento de Imagem Assistida por Computador/métodos , Volume Sistólico/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Algoritmos , Reprodutibilidade dos Testes , Sístole/fisiologia
8.
Magn Reson Med ; 92(3): 1248-1262, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38733066

RESUMO

PURPOSE: To present and assess an outlier mitigation method that makes free-running volumetric cardiovascular MRI (CMR) more robust to motion. METHODS: The proposed method, called compressive recovery with outlier rejection (CORe), models outliers in the measured data as an additive auxiliary variable. We enforce MR physics-guided group sparsity on the auxiliary variable, and jointly estimate it along with the image using an iterative algorithm. For evaluation, CORe is first compared to traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method using two simulation studies. Then, CORe is compared to CS using seven three-dimensional (3D) cine, 12 rest four-dimensional (4D) flow, and eight stress 4D flow imaging datasets. RESULTS: Our simulation studies show that CORe outperforms CS, RR, and the existing outlier rejection method in terms of normalized mean square error and structural similarity index across 55 different realizations. The expert reader evaluation of 3D cine images demonstrates that CORe is more effective in suppressing artifacts while maintaining or improving image sharpness. Finally, 4D flow images show that CORe yields more reliable and consistent flow measurements, especially in the presence of involuntary subject motion or exercise stress. CONCLUSION: An outlier rejection method is presented and tested using simulated and measured data. This method can help suppress motion artifacts in a wide range of free-running CMR applications.


Assuntos
Algoritmos , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Artefatos , Simulação por Computador , Movimento (Física) , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Coração/diagnóstico por imagem
9.
Magn Reson Med ; 91(5): 1936-1950, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38174593

RESUMO

PURPOSE: Widely used conventional 2D T2 * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T2 * technique that enables rapid whole-heart coverage was developed and validated. METHODS: A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T2 * imaging. This approach was tested in healthy human volunteers and in swine before and after intravenous administration of ferumoxytol. RESULTS: Spatial-resolution matched T2 * images were acquired with 2-3-fold reduction in scan time using the proposed T2 * mapping approach relative to conventional T2 * mapping. Compared with the conventional approach, T2 * images acquired with the proposed method demonstrated reduced off-resonance and flow artifacts, leading to higher image quality and lower coefficient of variation in T2 *-weighted images of the myocardium of swine and humans. Mean myocardial T2 * values determined using the proposed and conventional approaches were highly correlated and showed minimal bias. CONCLUSION: The proposed non-ECG-gated, free-breathing, 3D T2 * imaging approach can be performed within 5 min or less. It can overcome critical image artifacts from undesirable cardiac and respiratory motion and bulk off-resonance shifts at the heart-lung interface. The proposed approach is expected to facilitate faster and improved cardiac T2 * mapping in those with limited breath-holding capacity or arrhythmias.


Assuntos
Coração , Miocárdio , Humanos , Animais , Suínos , Coração/diagnóstico por imagem , Respiração , Suspensão da Respiração , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Imageamento Tridimensional/métodos
10.
Rheumatology (Oxford) ; 63(2): 482-489, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37216899

RESUMO

OBJECTIVES: We aimed to perform a comprehensive analysis of the ECG, two-dimensional echocardiography (2DE) and cardiac MRI (CMR) findings in patients with systemic sclerosis (SSc), and also to investigate correlations between CMR findings and some ECG and echocardiography (ECHO) results. METHODS: We retrospectively analysed data from patients with SSc who were regularly seen at our outpatient referral centre, all assessed with ECG, Doppler ECHO and CMR. RESULTS: Ninety-three patients were included; mean (s.d.) age of 48.5 (10.3) years, 86% female, 52% diffuse SSc. Eighty-four (90%) of the patients had sinus rhythm. The most common ECG finding was the left anterior fascicular block, recorded in 26 patients (28%). The abnormal septal motion (ASM) was found in 43 (46%) patients on ECHO. Myocardial involvement (inflammation or fibrosis), as assessed by multiparametric CMR, was present in >50% of our patients. The age- and sex-adjusted model showed that ASM on ECHO increased significantly the odds of increased extracellular volume [odds ratio (OR) 4.43, 95% CI 1.73, 11.38], increased T1 Relaxation time (OR 2.67, 95% CI 1.09, 6.54), increased T2 Relaxation time (OR 2.56, 95% CI 1.05, 6.22), increased signal intensity ratio in T2-weighted imaging (OR 2.56, 95% CI 1.05, 6.22), presence of late gadolinium enhancement (OR 3.85, 95% CI 1.52, 9.76) and mid-wall fibrosis (OR 3.64, 95% CI 1.48, 8.96). CONCLUSION: This study indicates that the presence of ASM on ECHO is a predictor of abnormal CMR in SSc patients, and a precise assessment of ASM may serve as an important point for selecting the patients that should be evaluated by CMR for early detection of myocardial involvement.


Assuntos
Meios de Contraste , Escleroderma Sistêmico , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Função Ventricular Esquerda , Gadolínio , Imageamento por Ressonância Magnética , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/diagnóstico por imagem , Miocárdio/patologia , Fibrose , Ecocardiografia , Espectroscopia de Ressonância Magnética , Imagem Cinética por Ressonância Magnética
11.
J Cardiovasc Electrophysiol ; 35(6): 1069-1077, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38509335

RESUMO

INTRODUCTION: Bicuspid aortic valves (BAV) are the most common congenital heart defects and the extent of ventricular arrhythmias (VA) in patients with BAV is unclear. The objective of this study is to describe VAs and late gadolinium enhancement cardiac magnetic resonance imaging (LGE-CMR) in patients with BAV. METHODS: A total of 19 patients with BAV (18 males, age: 58 ± 13 years) were referred for VA ablation procedures. Ten patients had BAVs at the time of ablation, nine patients had prior aortic valve replacement for a BAV. All but one patient had LGE-CMR and all patients underwent programmed ventricular stimulation at the time of the ablation. RESULTS: Frequent PVCs were the targeted VAs in 17/19 patients and VT in 2/19 patients. Monomorphic ventricular tachycardia (VT) was inducible in 6 patients. A total of 15 VTs were inducible (2.5 ± 1.0 VTs per patient with a mean cycle length of 322 ± 83 msec). LGE was present in 13 patients. Patients with inducible VT had larger borderzone and core scar compared to non-inducible patients (7.8 ± 2.1 cm3 vs. 2.5 ± 3.1 cm3 and 5.1 ± 2.6 cm3 vs. 1.9 ± 3.0 cm3, p-value < .05 for both). PVCs and VTs were mapped to the periaortic valve area in 12 patients and 4 patients, respectively. The PVC burden was reduced from 27 ± 13 to 3 ± 6 (p < .001) and the ejection fraction improved from 49 ± 13% to 55 ± 9% (p = .005). CONCLUSIONS: VAs in patients with BAV often originate from the perivalvular area and patients often have LGE and inducible VT. LGE may be due to ventricular remodeling secondary to the presence of BAV and harbors the arrhythmogenic substrate for VT.


Assuntos
Doença da Válvula Aórtica Bicúspide , Taquicardia Ventricular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/complicações , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Idoso , Adulto , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Ablação por Cateter , Potenciais de Ação , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Frequência Cardíaca , Resultado do Tratamento , Fatores de Risco , Valor Preditivo dos Testes , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas , Meios de Contraste/administração & dosagem , Imagem Cinética por Ressonância Magnética
12.
Cardiovasc Diabetol ; 23(1): 35, 2024 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-38245750

RESUMO

BACKGROUND: Diabetes mellitus (DM) is associated with a worse prognosis in patients with heart failure. Our aim was to analyze the clinical and imaging features of patients with DM and their association with outcomes in comparison to nondiabetic patients in a cohort of patients with nonischemic dilated cardiomyopathy (DCM). METHODS: This is a prospective cohort study of patients with DCM evaluated in a tertiary care center from 2018 to 2021. Transthoracic echocardiography and cardiac magnetic resonance findings were assessed. A high-risk late gadolinium enhancement (LGE) pattern was defined as epicardial, transmural, or septal plus free-wall. The primary outcome was a composite of heart failure hospitalizations and all-cause mortality. Multivariable analyses were performed to evaluate the impact of DM on outcomes. RESULTS: We studied 192 patients, of which 51 (26.6%) had DM. The median left ventricular ejection fraction was 30%, and 106 (55.2%) had LGE. No significant differences were found in systolic function parameters between patients with and without DM. E/e values were higher (15 vs. 11.9, p = 0.025), and both LGE (68.6% vs. 50.4%; p = 0.025) and a high-risk LGE pattern (31.4% vs. 18.5%; p = 0.047) were more frequently found in patients with DM. The primary outcome occurred more frequently in diabetic patients (41.2% vs. 23.6%, p = 0.017). DM was an independent predictor of outcomes (OR 2.01; p = 0.049) and of LGE presence (OR 2.15; p = 0.048) in the multivariable analysis. Patients with both DM and LGE had the highest risk of events (HR 3.1; p = 0.003). CONCLUSION: DM is related to a higher presence of LGE in DCM patients and is an independent predictor of outcomes. Patients with DM and LGE had a threefold risk of events. A multimodality imaging approach allows better risk stratification of these patients and may influence therapeutic options.


Assuntos
Cardiomiopatia Dilatada , Diabetes Mellitus , Insuficiência Cardíaca , Humanos , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico por imagem , Meios de Contraste , Volume Sistólico , Gadolínio , Função Ventricular Esquerda , Estudos Prospectivos , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Prognóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/complicações , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética
13.
Cardiovasc Diabetol ; 23(1): 48, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302987

RESUMO

BACKGROUND: The impact of the coexistence of type 2 diabetes mellitus (T2DM) in patients with non-ischemic dilated cardiomyopathy (DCM) on clinical profiles, myocardial fibrosis, and outcomes remain incompletely understood. METHOD: A total of 1152 patients diagnosed with non-ischemic DCM were prospectively enrolled from June 2012 to October 2021 and categorized into T2DM and non-T2DM groups. Clinical characteristics, cardiac function, and myocardial fibrosis evaluated by CMR were compared between the two groups. The primary endpoint included both all-cause mortality and heart transplantation. Cause of mortality was classified into heart failure death, sudden cardiac death, and non-cardiac death. Cox regression analysis and Kaplan-Meier analysis were performed to identify the association between T2DM and clinical outcomes. Propensity score matching (PSM) cohort including 438 patients was analyzed to reduce the bias from confounding covariates. RESULTS: Among the 1152 included DCM patients, 155 (13%) patients had T2DM. Patients with T2DM were older (55 ± 12 vs. 47 ± 14 years, P < 0.001), had higher New York Heart Association (NYHA) functional class (P = 0.003), higher prevalence of hypertension (37% vs. 21%, P < 0.001), atrial fibrillation (31% vs. 16%, P < 0.001), lower left ventricular (LV) ejection fraction (EF) (23 ± 9% vs. 27 ± 12%, P < 0.001), higher late gadolinium enhancement (LGE) presence (55% vs. 45%, P = 0.02), and significantly elevated native T1 (1323 ± 81ms vs. 1305 ± 73ms, P = 0.01) and extracellular volume fraction (ECV) (32.7 ± 6.3% vs. 31.3 ± 5.9%, P = 0.01) values. After a median follow-up of 38 months (interquartile range: 20-57 months), 239 patients reached primary endpoint. Kaplan-Meier analysis showed that patients with T2DM had worse clinical outcomes compared with those without T2DM in the overall cohort (annual events rate: 10.2% vs. 5.7%, P < 0.001). T2DM was independently associated with an increased risk of primary endpoint in the overall (Hazard ratio [HR]: 1.61, 95% CI: 1.13-2.33, P = 0.01) and PSM (HR: 1.54, 95% CI: 1.05-2.24, P = 0.02) cohorts. Furthermore, T2DM was associated with a higher risk of heart failure death (P = 0.006) and non-cardiac death (P = 0.02), but not sudden cardiac death (P = 0.16). CONCLUSIONS: Patients with T2DM represented a more severe clinical profile and experienced more adverse outcomes compared to those without T2DM in a large DCM cohort. TRIAL REGISTRATION: Trial registration number: ChiCTR1800017058; URL: https://www. CLINICALTRIALS: gov .


Assuntos
Cardiomiopatia Dilatada , Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Humanos , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/complicações , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Meios de Contraste , Estudos Prospectivos , Imagem Cinética por Ressonância Magnética/efeitos adversos , Gadolínio , Prognóstico , Volume Sistólico , Fibrose , Insuficiência Cardíaca/diagnóstico , Valor Preditivo dos Testes
14.
Cardiovasc Diabetol ; 23(1): 303, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39152461

RESUMO

BACKGROUND: Patients with diabetes have an increased risk of developing heart failure with preserved ejection fraction (HFpEF). This study aimed to compare indices of myocardial deformation and perfusion between patients with type 2 diabetes mellitus (T2DM) with and without HFpEF and to investigate the relationship between myocardial strain and perfusion reserve. METHODS: This study included 156 patients with T2DM without obstructive coronary artery disease (CAD) and 50 healthy volunteers who underwent cardiac magnetic resonance (CMR) examination at our center. Patients with T2DM were subdivided into the T2DM-HFpEF (n = 74) and the T2DM-non-HFpEF (n = 82) groups. The parameters of left ventricular (LV) and left atrial (LA) strain as well as stress myocardial perfusion were compared. The correlation between myocardial deformation and perfusion parameters was also assessed. Mediation analyses were used to evaluate the direct and indirect effects of T2DM on LA strain. RESULTS: Patients with T2DM and HFpEF had reduced LV radial peak systolic strain rate (PSSR), LV circumferential peak diastolic strain rate (PDSR), LA reservoir strain, global myocardial perfusion reserve index (MPRI), and increased LA booster strain compared to patients with T2DM without HFpEF (all P < 0.05). Furthermore, LV longitudinal PSSR, LA reservoir, and LA conduit strain were notably impaired in patients with T2DM without HFpEF compared to controls (all P < 0.05), but LV torsion, LV radial PSSR, and LA booster strain compensated for these alterations (all P < 0.05). Multivariate linear regression analysis demonstrated that LA reservoir and LA booster strain were independently associated with global MPRI (ß = 0.259, P < 0.001; ß = - 0.326, P < 0.001, respectively). Further, the difference in LA reservoir and LA booster strain between patients with T2DM with and without HFpEF was totally mediated by global MPRI. Global stress PI, LA booster, global rest PI, and global MPRI showed high accuracy in diagnosing HFpEF among patients with T2DM (areas under the curve [AUC]: 0.803, 0.790, 0.740, 0.740, respectively). CONCLUSIONS: Patients with T2DM and HFpEF exhibited significant LV systolic and diastolic deformation, decreased LA reservoir strain, severe impairment of myocardial perfusion, and elevated LA booster strain that is a compensatory response in HFpEF. Global MPRI was identified as an independent influencing factor on LA reservoir and LA booster strain. The difference in LA reservoir and LA booster strain between patients with T2DM with and without HFpEF was totally mediated by global MPRI, suggesting a possible mechanistic link between microcirculation impairment and cardiac dysfunction in diabetes. Myocardial perfusion and LA strain may prove valuable for diagnosing and managing HFpEF in the future.


Assuntos
Função do Átrio Esquerdo , Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 2/fisiopatologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Idoso , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/diagnóstico , Circulação Coronária , Estudos de Casos e Controles , Contração Miocárdica
15.
Cardiovasc Diabetol ; 23(1): 293, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118078

RESUMO

BACKGROUND: The adverse prognostic impact of diabetes on hypertrophic cardiomyopathy (HCM) is poorly understood. We sought to explore the underlying mechanisms in terms of structural and functional remodelling in HCM patients with coexisting diabetes (HCM-DM). METHODS: A total of 45 HCM-DM patients were retrospectively included. Isolated HCM controls (HCM patients without diabetes) were matched to HCM-DM patients in terms of maximal wall thickness, age, and gender distribution. Left ventricular (LV) and atrial (LA) performance were evaluated using cardiac magnetic resonance feature tracking strain analyses. The associations between diabetes and LV/LA impairment were investigated by univariable and multivariable linear regression. RESULTS: Compared with the isolated HCM controls, the HCM-DM patients had smaller end-diastolic volume and stroke volume, lower ejection fraction, larger mass/volume ratio and impaired strains in all three directions (all P < 0.05). In terms of the LA parameters, HCM-DM patients presented impaired LA reservoir and conduit strain/strain rate (all P < 0.05). Among all HCM patients, comorbidity with diabetes was independently associated with a low LV ejection fraction (ß = - 6.05, P < 0.001) and impaired global longitudinal strain (ß = 1.40, P = 0.007). Moreover, compared with the isolated HCM controls, HCM-DM patients presented with more myocardial fibrosis according to late gadolinium enhancement, which was an independent predictor of impaired LV global radial strain (ß = - 45.81, P = 0.008), LV global circumferential strain (ß = 18.25, P = 0.003), LA reservoir strain (ß = - 59.20, P < 0.001) and strain rate (ß = - 2.90, P = 0.002). CONCLUSIONS: Diabetes has adverse effects on LV and LA function in HCM patients, which may be important contributors to severe manifestations and outcomes in those patients. The present study strengthened the evidence of the prevention and management of diabetes in HCM patients.


Assuntos
Função do Átrio Esquerdo , Cardiomiopatia Hipertrófica , Diabetes Mellitus , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Cardiomiopatia Hipertrófica/complicações , Estudos Retrospectivos , Idoso , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/fisiopatologia , Diabetes Mellitus/diagnóstico , Fatores de Risco , Adulto , Prognóstico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Comorbidade , Remodelamento Atrial
16.
Cardiovasc Diabetol ; 23(1): 294, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118075

RESUMO

BACKGROUND: Patients with concomitant type 2 diabetes mellitus (T2DM) and aortic regurgitation (AR) can present with right ventricular (RV) dysfunction. The current study aimed to evaluate the impact of AR on RV impairment and the importance of ventricular interdependence using cardiac magnetic resonance feature tracking (CMR­FT) in patients with T2DM. METHODS: This study included 229 patients with T2DM (AR-), 88 patients with T2DM (AR+), and 122 healthy controls. The biventricular global radial strain (GRS), global circumferential strain (GCS), and global longitudinal peak strain (GLS) were calculated with CMR­FT and compared among the healthy control, T2DM (AR-), and T2DM (AR+) groups. The RV regional strains at the basal, mid, and apical cavities between the T2DM (AR+) group and subgroups with different AR degrees were compared. Backward stepwise multivariate linear regression analyses were performed to determine the effects of AR and left ventricular (LV) strains on RV strains. RESULTS: The RV GLS, LV GRS, LV GCS, LV GLS, interventricular septal (IVS) GRS and IVS GCS were decreased gradually from the controls through the T2DM (AR-) group to the T2DM (AR+) group. The IVS GLS of the T2DM (AR-) and T2DM (AR+) groups was lower than that of the control group. AR was independently associated with LV GRS, LV GCS, LV GLS, RV GCS, and RV GLS. If AR and LV GLSs were included in the regression analyses, AR and LV GLS were independently associated with RV GLS. CONCLUSION: AR can exacerbate RV dysfunction in patients with T2DM, which may be associated with the superimposed strain injury of the left ventricle and interventricular septum. The RV longitudinal and circumferential strains are important indicators of cardiac injury in T2DM and AR. The unfavorable LV-RV interdependence supports that while focusing on improving LV function, RV dysfunction should be monitored and treated in order to slow the progression of the disease and the onset of adverse outcomes.


Assuntos
Insuficiência da Valva Aórtica , Diabetes Mellitus Tipo 2 , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Disfunção Ventricular Direita , Função Ventricular Esquerda , Função Ventricular Direita , Humanos , Masculino , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/fisiopatologia , Diabetes Mellitus Tipo 2/diagnóstico , Idoso , Estudos Retrospectivos , Adulto , Estudos de Casos e Controles , Fatores de Risco , Fenômenos Biomecânicos
17.
Cardiovasc Diabetol ; 23(1): 266, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39039567

RESUMO

BACKGROUND: Heart failure with reduced ejection fraction (HFrEF) is associated with a high rate of mortality and morbidity. Evidence has shown that sex differences may be an important contributor to phenotypic heterogeneity in patients with HFrEF. Although diabetes mellitus (DM) frequently coexists with HFrEF and results in a worse prognosis, there remains a need to identify sex-related differences in the characteristics and outcomes of this population. In this study, we aimed to investigate the between-sex differences in clinical profile, left ventricular (LV) remodeling, and cardiovascular risk factors and outcomes in patients with HFrEF concomitant with DM. METHODS: A total of 273 patients with HFrEF concomitant with DM who underwent cardiac MRI were included in this study. Clinical characteristics, LV remodeling as assessed by cardiac MRI, and cardiovascular risk factors and outcomes were compared between sexes. RESULTS: Women were older, leaner and prone to have anemia and hypoproteinemia but less likely to have ischemic etiology. Cardiac MRI revealed that despite similar LVEFs between the sexes, there was more LV concentric remodeling, less impaired global systolic peak strain in longitudinal and circumferential components and a decreased likelihood of late gadolinium enhancement presence in women than in men. During a median follow-up time of 34.6 months, women exhibited better overall survival than men did (log-rank P = 0.042). Multivariable Cox proportional hazards analysis indicated different risk factors for predicting outcomes between sexes, with hypertension [hazard ratio (HR) = 2.05, 95% confidence interval (CI) 1.05 to 4.85, P = 0.041] and hypoproteinemia (HR = 2.27, 95% CI 1.06 to 4.37, P = 0.039) serving as independent determinants of outcomes in women, whereas ischemic etiology (HR = 1.96, 95% CI 1.11 to 3.48, P = 0.021) and atrial fibrillation (HR = 1.86, 95% CI 1.02 to 3.41, P = 0.044) served as independent determinants of outcomes in men. CONCLUSIONS: Among patients with HFrEF concomitant with DM, women displayed different LV remodeling and risk factors and had better survival than men did. Sex-based phenotypic heterogeneity in patients with HFrEF in the context of DM should be addressed in clinical practice.


Assuntos
Insuficiência Cardíaca , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular , Humanos , Feminino , Masculino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Prognóstico , Valor Preditivo dos Testes , Disparidades nos Níveis de Saúde , Fatores de Risco , Imagem Cinética por Ressonância Magnética , Fatores de Tempo , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Medição de Risco , Diabetes Mellitus/mortalidade , Diabetes Mellitus/fisiopatologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Fatores de Risco de Doenças Cardíacas
18.
Cardiovasc Diabetol ; 23(1): 133, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654269

RESUMO

BACKGROUND: Metabolic syndrome (MetS) can increase the risk of morbidity and mortality of cardiovascular disease and obstructive coronary artery disease (OCAD), which usually have a poor prognosis. This study aimed to explore the impact of MetS on left ventricular (LV) deformation and function in OCAD patients and investigate the independent factors of impaired LV function and deformation. MATERIALS AND METHODS: A total of 121 patients with OCAD and 52 sex- and age-matched controls who underwent cardiac magnetic resonance scanning were enrolled in the study. All OCAD patients were divided into two groups: OCAD with MetS [OCAD(MetS+), n = 83] and OCAD without MetS [OCAD(MetS-), n = 38]. LV functional and global strain parameters were measured and compared among the three groups. Multivariable linear regression analyses were constructed to investigate the independent factors of LV impairment in OCAD patients. Logistic regression analysis and receiver operating characteristic (ROC) curve analysis were performed to test the prediction efficiency of MetS for LV impairment. RESULTS: From controls to the OCAD(MetS-) group to the OCAD(MetS+) group, LV mass (LVM) increased, and LV global function index (LVGFI) and LV global longitudinal peak strain (GLPS) decreased (all p < 0.05). Compared with the OCAD(MetS-) group, the LV GLPS declined significantly (p = 0.027), the LVM increased (p = 0.006), and the LVGFI decreased (p = 0.043) in the OCAD(MetS+) group. After adjustment for covariates in OCAD patients, MetS was an independent factor of decreased LV GLPS (ß = - 0.211, p = 0.002) and increased LVM (ß = 0.221, p = 0.003). The logistic multivariable regression analysis and ROC analysis showed that combined MetS improved the efficiency of predicting LV GLPS reduction (AUC = 0.88) and LVM (AUC = 0.89) increase. CONCLUSIONS: MetS aggravated the damage of LV deformation and function in OCAD patients and was independently associated with LV deformation and impaired LV strain. Additionally, MetS increased the prediction efficiency of increased LVM and decreased LV GLPS. Early detection and intervention of MetS in patients with OCAD is of great significance.


Assuntos
Síndrome Metabólica , Valor Preditivo dos Testes , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Síndrome Metabólica/fisiopatologia , Síndrome Metabólica/complicações , Síndrome Metabólica/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Idoso , Estudos de Casos e Controles , Medição de Risco , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/complicações , Imagem Cinética por Ressonância Magnética , Fatores de Risco , Prognóstico , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/complicações
19.
Cardiovasc Diabetol ; 23(1): 317, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39192259

RESUMO

BACKGROUND: Type 2 diabetes mellitus (T2DM) and metabolic-associated fatty liver disease (MAFLD) are both metabolic disorders that negatively impact the cardiovascular system. This study comprehensively analyzed the additive effect of MAFLD on left ventricular function and global strain in T2DM patients by cardiac magnetic resonance (CMR). METHODS: Data of 261 T2DM patients, including 109 with and 152 without MAFLD, as well as 73 matched normal controls from our medical center between June 2015 and March 2022 were retrospectively analyzed. CMR-derived parameters, including LV function and global strain parameters, were compared among different groups. Univariate and multivariate linear regression analyses were conducted to investigate the impact of various factors on LV function and global strain. RESULTS: Our investigation revealed a progressive deterioration in LV functional parameters across three groups: control subjects, T2DM patients without MAFLD, and T2DM patients with MAFLD. Statistically significant increases in left ventricular end-diastolic volume index (LVEDVI), left ventricular end-systolic volume index (LVESVI), left ventricular mass index (LVMI) were observed, along with decreases in left ventricular ejection fraction (LVEF) and left ventricular global function index (LVGFI). Among these three groups, significant reductions were also noted in the absolute values of LV global radial, circumferential, and longitudinal peak strains (GRPS, GCPS, and GLPS), as well as in peak systolic (PSSR) and peak diastolic strain rates (PDSR). MAFLD was identified as an independent predictor of LVEF, LVMI, LVGFI, GRPS, GCPS, and GLPS in multivariate linear analysis. Besides, the incidence of late gadolinium enhancement was higher in MAFLD patients than in non-MAFLD patients (50/109 [45.9%] vs. 42/152 [27.6%], p = 0.003). Furthermore, escalating MAFLD severity was associated with a numerical deterioration in both LV function parameters and global strain values. CONCLUSIONS: This study thoroughly compared CMR parameters in T2DM patients with and without MAFLD, uncovering MAFLD's adverse impact on LV function and deformation in T2DM patients. These findings highlight the critical need for early detection and comprehensive management of cardiac function in T2DM patients with MAFLD.


Assuntos
Diabetes Mellitus Tipo 2 , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatologia , Diabetes Mellitus Tipo 2/epidemiologia , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Idoso , Fatores de Risco , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/fisiopatologia , Hepatopatia Gordurosa não Alcoólica/complicações , Volume Sistólico , Adulto , Cardiomiopatias Diabéticas/fisiopatologia , Cardiomiopatias Diabéticas/diagnóstico por imagem , Cardiomiopatias Diabéticas/etiologia , Fenômenos Biomecânicos
20.
Cardiovasc Diabetol ; 23(1): 148, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38685007

RESUMO

BACKGROUND: Glycemic control, as measured by glycosylated hemoglobin (HbA1c), is an important biomarker to evaluate diabetes severity and is believed to be associated with heart failure development. Type 2 diabetes mellitus (T2DM) and heart failure with reduced ejection fraction (HFrEF) commonly coexist, and the combination of these two diseases indicates a considerably poorer outcome than either disease alone. Therefore, glycemic control should be carefully managed. The present study aimed to explore the association between glycemic control and clinical outcomes, and to determine the optimal glycemic target in this specific population. METHODS: A total of 262 patients who underwent cardiac MRI were included and were split by HbA1c levels [HbA1c < 6.5% (intensive control), HbA1c 6.5-7.5% (modest control), and HbA1c > 7.5% (poor control)]. The biventricular volume and function, as well as left ventricular (LV) systolic strains in patients in different HbA1c categories, were measured and compared. The primary and secondary outcomes were recorded. The association of different HbA1c levels with adverse outcomes was assessed. RESULTS: Despite similar biventricular ejection fractions, both patients with intensive and poor glycemic control exhibited prominent deterioration of LV systolic strain in the longitudinal component (P = 0.004). After a median follow-up of 35.0 months, 55 patients (21.0%) experienced at least one confirmed endpoint event. Cox multivariable analysis indicated that both patients in the lowest and highest HbA1c categories exhibited a more than 2-fold increase in the risk for primary outcomes [HbA1c < 6.5%: hazard ratio (HR) = 2.42, 95% confidence interval (CI) = 1.07-5.45; P = 0.033; HbA1c > 7.5%: HR = 2.24, 95% CI = 1.01-4.99; P = 0.038] and secondary outcomes (HbA1c < 6.5%: HR = 2.84, 95% CI = 1.16-6.96; P = 0.022; HbA1c > 7.5%: HR = 2.65, 95% CI = 1.08-6.50; P = 0.038) compared with those in the middle HbA1c category. CONCLUSIONS: We showed a U-shaped association of glycemic control with clinical outcomes in patients with T2DM and HFrEF, with the lowest risk of adverse outcomes among patients with modest glycemic control. HbA1c between 6.5% and 7.5% may be served as the optimal hypoglycemic target in this specific population.


Assuntos
Biomarcadores , Glicemia , Diabetes Mellitus Tipo 2 , Hemoglobinas Glicadas , Controle Glicêmico , Insuficiência Cardíaca , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular , Humanos , Masculino , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico por imagem , Hemoglobinas Glicadas/metabolismo , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatologia , Idoso , Glicemia/metabolismo , Biomarcadores/sangue , Fatores de Risco , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética , Fatores de Tempo , Hipoglicemiantes/uso terapêutico , Medição de Risco , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA