Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.694
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Perfusion ; 38(4): 863-867, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35491903

RESUMO

Modifying cardiopulmonary bypass (CPB) circuit's priming technique before the onset of CPB in cardiac patients known with sickle-cell disease or sickle cell trait has been observed to be of substantial significance in dealing with such challenges without having any life-threatening consequences. We modified our routine heparinized crystalloid priming of the CPB circuit with partial exchange transfusion by adding donor blood (packed red blood cells), fresh frozen plasma (FFP), and bicarbonate. This has helped us bring down the overall sickle cell hemoglobin in the blood thereby reducing its risk of sickling.


Assuntos
Anemia Falciforme , Procedimentos Cirúrgicos Cardíacos , Traço Falciforme , Humanos , Ponte Cardiopulmonar/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Máquina Coração-Pulmão , Anemia Falciforme/complicações , Anemia Falciforme/cirurgia
2.
Xenotransplantation ; 29(3): e12749, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35616211

RESUMO

INTRODUCTION: After orthotopic cardiac xenotransplantation, the combination of both the inflammatory responses to the exposure of a recipient to the xenogeneic organ and the use of cardiopulmonary bypass has been assumed to cause detrimental side effects. These have been described not only to affect the transplanted organ (heart) itself, but also the recipient's lungs. In this article, we summarize how these possible detrimental processes can be minimized or even avoided. METHODS: Data from eight pig-to-baboon orthotopic cardiac xenotransplantation experiments were analyzed with a special focus on early (within the first week) postoperative organ dysfunction and systemic inflammatory responses. Non-ischemic heart preservation and the careful management of the heart-lung machine were deemed essential to guarantee not only the immediate function of the transplanted xenogeneic organ but also the prompt recovery of the recipient. RESULTS: After weaning from cardiopulmonary bypass, very low catecholamine amounts were needed to ensure an adequate pump function and cardiac output. Central venous oxygen saturation and serum lactate levels remained within normal ranges. All animals were successfully weaned from ventilation within the first postoperative hours. Serum parameters of the transplants and native kidneys and livers were initially slightly elevated or always normal, as were hemoglobin, LDH, and platelet measurements. Markers of systemic inflammation, C-reactive protein, and IL-6 were slightly elevated, but the reactions caused no lasting damage. CONCLUSION: Consistent short-term and long-term results were achieved after orthotopic cardiac pig-to-baboon transplantation without detrimental inflammatory responses or signs of multiorgan failure. In comparison to allogeneic procedures, non-ischemic heart preservation was important for successful immediate organ function, as was the management of the heart-lung machine. Thus, we believe that genetically modified porcine hearts are ready for use in the clinical setting.


Assuntos
Transplante de Coração , Transplantes , Animais , Transplante de Coração/métodos , Máquina Coração-Pulmão , Inflamação , Papio , Suínos , Transplante Heterólogo/métodos
3.
J Extra Corpor Technol ; 54(2): 107-114, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35928337

RESUMO

Blood hemolysis caused by mechanical impact is a serious problem in medicine. In addition to the heart-lung machine (artificial surfaces, flow irritating connection points) which contributes to hemolysis, blood suction and surgical suction devices are influencing factors. Goal of our research is to develop best flow optimizing suction geometry that represents the best compromise between all influencing effects. Based on data that negative pressure and turbulence have a negative impact on blood components, 27 surgical suction tips have been examined for acoustic stress and negative pressure behavior. Furthermore, a dimensionless factor Q was introduced to assess the overall performance of the suction tips investigated.


Assuntos
Transfusão de Sangue Autóloga , Ponte Cardiopulmonar , Máquina Coração-Pulmão , Hemólise , Humanos , Sucção
4.
J Extra Corpor Technol ; 54(3): 242-249, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36742211

RESUMO

Intraoperative management for patients during orthotopic lung transplantation may be performed without mechanical circulatory support, with veno-arterial extracorporeal membrane oxygenation (VA-ECMO), or cardiopulmonary bypass (CPB). For certain patients, an intraoperative conversion from VA-ECMO to CPB may be indicated. If a VA-ECMO patient requires CPB conversion, the previous model at our institution used two separate machines and was overall inefficient. The primary aim of this project was to develop a CPB pack modification to create a circuit that easily converts from VA-ECMO to CPB if indicated. The secondary aim was to create new supportive protocols and a comprehensive education and training curriculum for our large perfusion department to enhance patient safety. The new circuit was carefully designed and evaluated to minimize changes to the current CPB circuit while allowing for the safest configuration of VA-ECMO. A new protocol was designed with multi-disciplinary collaboration. A comprehensive education and training curriculum, as well as an objective competency assessment tool, were created. The circuit was subjectively evaluated by perfusionists and outscored our previous model in the areas of ease of setup, use, and CPB conversion. It received positive feedback from cardiothoracic surgeons and anesthesiologists as well. Lastly, it provided a financial benefit to our institution.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Pulmão , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Ponte Cardiopulmonar/métodos , Perfusão , Transplante de Pulmão/métodos , Máquina Coração-Pulmão , Estudos Retrospectivos
5.
Perfusion ; 37(4): 331-333, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-33739181

RESUMO

BACKGROUND: Monitoring oxygen delivery to the oxygenator of a heart lung machine (HLM) is typically accomplished with an O2 analyzer connected to the gas inflow line. It is assumed when the FiO2 is greater than 21% that oxygen is being delivered to the oxygenator. However, this assumption is imperfect because the connection of the inflow line to the oxygenator is downstream from the O2 analyzer. FiO2 monitoring will not alert the perfusionist if the inflow line is not actually connected to the oxygenator. Measuring the fraction of expired oxygen (FEO2) is a more reliable way of monitoring O2 delivery. METHODS: An O2 analyzer was placed on the scavenging line that is attached to the exhaust port of oxygenator (FEO2). RESULTS: Whenever the FiO2 is greater than 21%, and the inflow line is properly connected, the FEO2 exiting the oxygenator is greater than 21%. The FEO2 falls to 21% when the inflow line is not functioning. CONCLUSION: Monitoring the FEO2 is a more reliable way to verify O2 delivery to an oxygenator. An alarm can be set on the FEO2 monitor to alert the perfusionist if the FEO2 falls below a predetermined threshold so any issue with O2 delivery will always be recognized.


Assuntos
Máquina Coração-Pulmão , Oxigênio , Ponte Cardiopulmonar , Humanos , Monitorização Fisiológica , Oxigenadores
6.
Lasers Med Sci ; 36(4): 783-790, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32651700

RESUMO

The optical properties of hemoglobin could indicate the degree of hemolysis. We aimed to utilize this to develop a real-time blood damage monitoring device for cardiopulmonary bypass (CPB) systems. The real-time blood damage monitoring device comprised a near-infrared spectroscopy optical module with a fiber spectrometer and monitoring platform and computer software developed using LabVIEW 2017. The fiber spectrometer operated at wavelengths of 545, 660, and 940 nm and contained a detector fiber bundle (source-detector distance = 1.0-2.5 cm). CPB operation was simulated using an artificial heart-lung machine with a flow rate of 3, 4, or 5 L/min. Four hundred milliliter of anticoagulated porcine blood was continuously rotated for 4 h. The transmittance, reflectivity, and absorbance of the blood were measured using the optical device at a frequency of 25 Hz and then digitally averaged into 1-s interval. Samples of damaged blood were collected at regular intervals for in vitro hemolysis tests to calculate the normalized index of hemolysis (NIH). All experiments were repeated three times. We prepared 28 blood bags containing 400 ml of anticoagulant. Paired t test was used to examine the test-retest reliability of the differences between the three methods and control samples. Statistical tests revealed significant differences in the mean values between the test and control groups over time (P < 0.01). Relationship was established between the real-time monitoring results and the NIH values. An effective blood damage detection method that combined in vitro hemolysis tests and near-infrared spectroscopy was achieved. The results demonstrate the clinical potential of a real-time, low-cost, and reliable blood damage monitoring device to improve the safety of CPB operation.


Assuntos
Ponte Cardiopulmonar/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho , Máquina Coração-Pulmão , Hemoglobinas/metabolismo , Hemólise , Humanos , Reprodutibilidade dos Testes
7.
J Extra Corpor Technol ; 53(2): 140-145, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34194081

RESUMO

Blood-primed cardiopulmonary bypass circuits are frequently necessary to achieve safe support during pediatric open-heart surgery. Literature is lacking regarding suitable prime constituents or methods for achieving a physiologically appropriate blood-primed circuit. We examined the chemistry and hematology of neonatal blood-primed circuits from the conclusion of the priming procedure until the initiation of bypass. Base deficit/excess, pH, pO2, pCO2, HCO3, glucose, sodium, potassium, calcium, hematocrit, lactate, and osmolality were analyzed. Any deviation over time from the original prime value was compared for significance. Statistically significant changes were found between T0 and all time points for all parameters, except for pH and pO2 out to 1 hour. Among all parameters, various rates of change were observed. Although most changes in the parameters were found to be statistically significant, those changes may not be clinically significant based on clinician interpretation. Attention to the prime quality beyond the immediate post-priming period may be beneficial. Should the time period between validation of the prime quality and initiation of bypass be extended, it may be advisable to reevaluate the prime quality.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Criança , Máquina Coração-Pulmão , Hematócrito , Humanos , Recém-Nascido
8.
J Extra Corpor Technol ; 53(3): 193-198, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34658411

RESUMO

The survival of congenital heart disease (CHD) patients with single-ventricle (SV) physiology has markedly increased as a result of advances in operative techniques and postsurgical management. Nonetheless, these patients remain highly susceptible to end-stage heart failure requiring cardiac replacement therapies at early ages. Given a worldwide shortage of transplantable organs, mechanical circulatory support (MCS) represents an alternative treatment option. The significant heterogeneity of the SV population presents unique indications for MCS that have begun to be evaluated. This case study describes a 12-year-old female with heterotaxy syndrome and an SV condition, previously palliated with a Fontan operation at another institution. The patient was placed on veno-arterial (VA) extracorporeal membrane oxygenation (ECMO) during prolonged cardiopulmonary resuscitation, and later underwent HeartWare ventricular assist device (HVAD) implantation as a bridge to transplantation (BTT). A novel method was chosen to optimize careful de-airing of the heart through a minimized cardiopulmonary bypass (CPB) setup, during full ECMO support and surgical insertion of the HeartWare. The ascending aorta was vented proximal to the HVAD outflow graft anastomosis through a minimized CPB circuit at <10% of the ECMO flow rate. This circuit adaption allowed for euvolemic resuscitation via connection from the minimized CPB circuit to the venous limb of the ECMO circuit. The transition from VA-ECMO to the HeartWare was well tolerated despite a challenging sternotomy and cardiac anomaly. A minimized bypass circuit proved efficacious for the benefit of volume resuscitation and safe de-airing of the HVAD while on ECMO support. The literature is limited concerning safe practices for implantation of durable VADs in complex SV patients coupled with those transitioning from varying modalities of MCS. As SV survivability regresses to heart failure, it is essential that we share techniques that aim to improve the long-term outcomes for successful BTT or bridge to decision (BTD).


Assuntos
Oxigenação por Membrana Extracorpórea , Cardiopatias Congênitas , Transplante de Coração , Coração Auxiliar , Criança , Feminino , Cardiopatias Congênitas/cirurgia , Máquina Coração-Pulmão , Humanos
9.
Perfusion ; 36(2): 210-212, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32613901

RESUMO

The AngioVac® is a vacuum-assisted percutaneous thrombectomy suction system. In critically ill patients, the sudden volume shift can result in abrupt hemodynamic changes thus leading to a cardiac right-left shunt with a high risk of paradoxical embolization. We describe a modified cardiopulmonary bypass circuit for the use of the AngioVac® system that enables full cardiopulmonary support and reduces paradoxical thromboembolic risk.


Assuntos
Ponte Cardiopulmonar , Trombectomia , Máquina Coração-Pulmão , Humanos , Sucção , Resultado do Tratamento
10.
Perfusion ; 36(8): 832-838, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33140696

RESUMO

OBJECTIVE: To investigate whether the miniaturized cardiopulmonary bypass (CPB) system decreased the usage of ultrafiltration (UF), and to explore whether the non-UF with miniaturized CPB strategy could get good clinical results during congenital heart surgery. METHODS: We performed a retrospective analysis of all patients undergoing congenital heart surgery with CPB at Shenzhen Children's Hospital from 1 May 2015 to 30 September 2019. We classified patients to UF with miniaturized CPB group, non-UF with miniaturized CPB group, UF with conventional CPB group and non-UF with conventional CPB group. RESULTS: Of the 2145 patients, 721 (33.6%) were in the conventional CPB group, and 1424 (66.4%) were in the miniaturized CPB group. The UF rate was significantly lower in the miniaturized CPB group compared with that in the conventional CPB group (12.5% vs. 76.8%, p < 0.001). Compared with patients in the other groups, patients in the non-UF with miniaturized CPB group had a shorter postoperative MV time (p < 0.05), and a shorter length of stay in the ICU (p < 0.001) and hospital (p < 0.001). The age of children in the UF with miniaturized CPB group was relatively younger (median: 1.5 months, IQR: 0.3-4.6 months), and the preoperative weight was relatively lower (median: 3.9 kg, IQR: 3.2-5.4 kg). Moreover, this group of children had a relatively longer postoperative MV time and length of stay in the ICU and hospital. CONCLUSION: The miniaturized CPB system could decrease the usage of UF. Good results were achieved in children who did not use UF based on the miniaturized CPB circuit system during congenital heart surgery.


Assuntos
Ponte Cardiopulmonar , Cardiopatias Congênitas , Criança , Cardiopatias Congênitas/cirurgia , Máquina Coração-Pulmão , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Ultrafiltração
11.
Cochrane Database Syst Rev ; 10: CD013101, 2020 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-33045104

RESUMO

BACKGROUND: Corticosteroids are routinely given to children undergoing cardiac surgery with cardiopulmonary bypass (CPB) in an attempt to ameliorate the inflammatory response. Their use is still controversial and the decision to administer the intervention can vary by centre and/or by individual doctors within that centre. OBJECTIVES: This review is designed to assess the benefits and harms of prophylactic corticosteroids in children between birth and 18 years of age undergoing cardiac surgery with CPB. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase and Conference Proceedings Citation Index-Science in June 2020. We also searched four clinical trials registers and conducted backward and forward citation searching of relevant articles. SELECTION CRITERIA: We included studies of prophylactic administration of corticosteroids, including single and multiple doses, and all types of corticosteroids administered via any route and at any time-point in the perioperative period. We excluded studies if steroids were administered therapeutically. We included individually randomised controlled trials (RCTs), with two or more groups (e.g. multi-drug or dose comparisons with a control group) but not 'head-to-head' trials without a placebo or a group that did not receive corticosteroids. We included studies in children, from birth up to 18 years of age, including preterm infants, undergoing cardiac surgery with the use of CPB. We also excluded studies in patients undergoing heart or lung transplantation, or both; studies in patients already receiving corticosteroids; in patients with abnormalities of the hypothalamic-pituitary-adrenal axis; and in patients given steroids at the time of cardiac surgery for indications other than cardiac surgery. DATA COLLECTION AND ANALYSIS: We used the Covidence systematic review manager to extract and manage data for the review. Two review authors independently assessed studies for inclusion, extracted data, and assessed risks of bias. We resolved disagreements by consensus or by consultation with a third review author. We assessed the certainty of evidence with GRADE. MAIN RESULTS: We found 3748 studies, of which 888 were duplicate records. Two studies had the same clinical trial registration number, but reported different populations and interventions. We therefore included them as separate studies. We screened titles and abstracts of 2868 records and reviewed full text reports for 84 studies to determine eligibility. We extracted data for 13 studies. Pooled analyses are based on eight studies. We reported the remaining five studies narratively due to zero events for both intervention and placebo in the outcomes of interest. Therefore, the final meta-analysis included eight studies with a combined population of 478 participants. There was a low or unclear risk of bias across the domains. There was moderate certainty of evidence that corticosteroids do not change the risk of in-hospital mortality (five RCTs; 313 participants; risk ratio (RR) 0.83, 95% confidence interval (CI) 0.33 to 2.07) for children undergoing cardiac surgery with CPB. There was high certainty of evidence that corticosteroids reduce the duration of mechanical ventilation (six RCTs; 421 participants; mean difference (MD) 11.37 hours lower, 95% CI -20.29 to -2.45) after the surgery. There was high-certainty evidence that the intervention probably made little to no difference to the length of postoperative intensive care unit (ICU) stay (six RCTs; 421 participants; MD 0.28 days lower, 95% CI -0.79 to 0.24) and moderate-certainty evidence that the intervention probably made little to no difference to the length of the postoperative hospital stay (one RCT; 176 participants; mean length of stay 22 days; MD -0.70 days, 95% CI -2.62 to 1.22). There was moderate certainty of evidence for no effect of the intervention on all-cause mortality at the longest follow-up (five RCTs; 313 participants; RR 0.83, 95% CI 0.33 to 2.07) or cardiovascular mortality at the longest follow-up (three RCTs; 109 participants; RR 0.40, 95% CI 0.07 to 2.46). There was low certainty of evidence that corticosteroids probably make little to no difference to children separating from CPB (one RCT; 40 participants; RR 0.20, 95% CI 0.01 to 3.92). We were unable to report information regarding adverse events of the intervention due to the heterogeneity of reporting of outcomes. We downgraded the certainty of evidence for several reasons, including imprecision due to small sample sizes, a single study providing data for an individual outcome, the inclusion of both appreciable benefit and harm in the confidence interval, and publication bias. AUTHORS' CONCLUSIONS: Corticosteroids  probably do not change the risk of mortality for children having heart surgery using CPB at any time point. They probably reduce the duration of postoperative ventilation in this context, but have little or no effect on the total length of postoperative ICU stay or total postoperative hospital stay. There was inconsistency in the adverse event outcomes reported which, consequently, could not be pooled. It is therefore impossible to provide any implications and policy-makers will be unable to make any recommendations for practice without evidence about adverse effects. The review highlighted the need for well-conducted RCTs powered for clinical outcomes to confirm or refute the effect of corticosteroids versus placebo in children having cardiac surgery with CPB. A core outcome set for adverse event reporting in the paediatric major surgery and intensive care setting is required.


Assuntos
Corticosteroides/uso terapêutico , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/efeitos adversos , Inflamação/prevenção & controle , Adolescente , Corticosteroides/efeitos adversos , Viés , Procedimentos Cirúrgicos Cardíacos/mortalidade , Ponte Cardiopulmonar/mortalidade , Causas de Morte , Criança , Pré-Escolar , Dexametasona/uso terapêutico , Máquina Coração-Pulmão/efeitos adversos , Mortalidade Hospitalar , Humanos , Hidrocortisona/uso terapêutico , Lactente , Recém-Nascido , Inflamação/etiologia , Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Tempo de Internação , Metilprednisolona/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Respiração Artificial/estatística & dados numéricos
12.
Artif Organs ; 44(8): 892-899, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32187389

RESUMO

Extracorporeal circulation is accompanied by changes in red blood cell morphology and structural integrity that affect cell function and survival, and thereby may contribute to the various side effects of heart-lung machine-assisted surgery. Our main objectives were to determine the effect of circulation of red blood cells in a stand-alone extracorporeal circuit on several parameters that are known to be affected by, as well as contribute to red blood cell aging. As a source of RBCs, we employed blood bank storage units of different ages. In order to assess the relevance of our in vitro observations for the characterization of extracorporal circulation technology, we compared these changes in those of patients undergoing extracorporeal circulation-assisted cardiac surgery. Our results show that circulation in a heart-lung machine is accompanied by changes in red blood cell volume, an increase in osmotic fragility, changes in deformability and aggregation behavior, and alterations in the exposure of phosphatidylserine and in microvesicle generation. RBCs from 1-week-old concentrates showed the highest similarities with the in vivo situation. These changes in key characteristics of the red blood cell aging process likely increase the susceptibility of red blood cells to the various mechanical, osmotic, and immunological stress conditions encountered during and after surgery in the patient's circulation, and thereby contribute to the side effects of surgery. Thus, aging-related parameters in red blood cell structure and function provide a foundation for the validation and improvement of extracorporeal circulation technology.


Assuntos
Eritrócitos/fisiologia , Máquina Coração-Pulmão/efeitos adversos , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Agregação Eritrocítica/fisiologia , Deformação Eritrocítica/fisiologia , Volume de Eritrócitos , Eritrócitos/patologia , Feminino , Hemólise , Humanos , Masculino
13.
J Biomed Inform ; 96: 103250, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31295623

RESUMO

The operating room (OR) is a high-risk and complex environment, where multiple specialized professionals work as a team to effectively care for patients in need of surgical interventions. Surgical tasks impose high cognitive demands on OR staff and cognitive overload may have deleterious effects on team performance and patient safety. The aim of the present study was to investigate the feasibility and describe a novel methodological approach to characterize dynamic changes in team cognitive load by measuring synchronization and entropy of heart rate variability parameters during real-life cardiac surgery. Cognitive load was measured by capturing interbeat intervals (IBI) from three team members (surgeon, anesthesiologist and perfusionist) using an unobtrusive wearable heart rate sensor and transmitted in real-time to a smartphone application. Clinical data and operating room audio/video recordings were also collected to provide behavioral and contextual information. We developed symbolic representations of the transient cognitive state of individual team members (Individual Cognitive State - ICS), and overall team (Team Cognitive State - TCS) by comparing IBI data from each team member with themselves and with others. The distribution of TCS symbols during surgery enabled us to display and analyze temporal states and dynamic changes of team cognitive load. Shannon's entropy was calculated to estimate the changing levels of team organization and to detect fluctuations resulting from a variety of cognitive demands and/or specific situations (e.g. medical error, emergency, flow disruptions). An illustrative example from a real cardiac surgery team shows how cognitive load patterns shifted rapidly after an actual near-miss medication event, leading the team to a more organized and synchronized state. The methodological approach described in this study provides a measurement technique for the assessment of team physiological synchronization, which can be applied to many other team-based environments. Future research should gather additional validity evidence to support the proposed methods for team cognitive load measurement.


Assuntos
Competência Clínica , Cognição , Salas Cirúrgicas , Equipe de Assistência ao Paciente , Cirurgiões , Análise e Desempenho de Tarefas , Comunicação , Ponte de Artéria Coronária , Entropia , Parada Cardíaca/cirurgia , Máquina Coração-Pulmão , Humanos , Isquemia/patologia , Erros Médicos/prevenção & controle , Monitorização Ambulatorial/instrumentação , Projetos Piloto , Centros de Atenção Terciária , Gravação em Vídeo
14.
BMC Cardiovasc Disord ; 19(1): 292, 2019 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-31835993

RESUMO

BACKGROUND: Recent scientific reports have brought into light a new concept of goal-directed perfusion (GDP) that aims to recreate physiological conditions in which the risk of end-organ malperfusion is minimalized. The aim of our study was to analyse patients' interim physiology while on cardiopulmonary bypass based on the haemodynamic and tissue oxygen delivery measurements. We also aimed to create a universal formula that may help in further implementation of the GDP concept. METHODS: We retrospectively analysed patients operated on at the Wroclaw University Hospital between June 2017 and December 2018. Since our observations provided an extensive amount of data, including the patients' demographics, surgery details and the perfusion-related data, the Data Science methodology was applied. RESULTS: A total of 272 (mean age 62.5 ± 12.4, 74% male) cardiac surgery patients were included in the study. To study the relationship between haemodynamic and tissue oxygen parameters, the data for three different values of DO2i (280 ml/min/m2, 330 ml/min/m2 and 380 ml/min/m2), were evaluated. Each set of those lines showed a descending function of CI in Hb concentration for the set DO2i. CONCLUSIONS: Modern calculation tools make it possible to create a common data platform from a very large database. Using that methodology we created models of haemodynamic compounds describing tissue oxygen delivery. The obtained unique patterns may both allow the adaptation of the flow in relation to the patient's unique morphology that changes in time and contribute to wider and safer implementation of perfusion strategy which has been tailored to every patient's individual needs.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Ciência de Dados , Modelos Cardiovasculares , Oxigênio/sangue , Idoso , Biomarcadores/sangue , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/instrumentação , Feminino , Máquina Coração-Pulmão , Hemodinâmica , Hemoglobinas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
15.
Thorac Cardiovasc Surg ; 67(6): 475-483, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30049018

RESUMO

BACKGROUND: Crystalloid priming is a cost-effective, free from immunological reactions, and independent from human plasma delivery. However, there is some debate on the negative impact of low plasma colloid pressure and higher incidence of systemic inflammatory response syndrome (SIRS). The aim of the study was to rule out any adverse effects of crystalloid priming on the postoperative outcome. METHODS: We investigated 520 consecutive patients, including emergencies, who had isolated on-pump coronary artery bypass grafting in 2009 by retrospective analysis in our clinic. Crystalloid priming (n = 294) was introduced as an alternative to albumin (n = 226). Reviewing patient charts and IT-based data generated a dataset of perioperative parameters. RESULTS: There were no differences with respect to demographical data and preexisting comorbidities between both groups. Despite equal perfusion times, more volume had to be substituted during extracorporeal circulation following crystalloid priming. However, this did not influence the inhospital outcomes. According to the definition of the "Sepsis-3 Guidelines," the incidence of SIRS was similar. There was no difference in the need for a vasopressor treatment, and only transient higher serum lactate levels were found in the crystalloid group. The incidence of neurologic and organ-related adverse events, as well as 30-day mortality was comparable. CONCLUSION: The use of crystalloid priming is safe in coronary artery bypass grafting surgery in adults. However, there might be a greater need for crystalloid fluids during surgery.


Assuntos
Albuminas/administração & dosagem , Soluções Cardioplégicas/administração & dosagem , Ponte de Artéria Coronária , Circulação Extracorpórea/instrumentação , Máquina Coração-Pulmão , Compostos de Potássio/administração & dosagem , Idoso , Albuminas/efeitos adversos , Soluções Cardioplégicas/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Circulação Extracorpórea/efeitos adversos , Circulação Extracorpórea/mortalidade , Feminino , Alemanha/epidemiologia , Glucose/administração & dosagem , Glucose/efeitos adversos , Máquina Coração-Pulmão/efeitos adversos , Humanos , Incidência , Masculino , Manitol/administração & dosagem , Manitol/efeitos adversos , Cloreto de Potássio/administração & dosagem , Cloreto de Potássio/efeitos adversos , Compostos de Potássio/efeitos adversos , Procaína/administração & dosagem , Procaína/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Síndrome de Resposta Inflamatória Sistêmica/epidemiologia , Fatores de Tempo , Resultado do Tratamento
16.
J Extra Corpor Technol ; 51(1): 20-25, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30936584

RESUMO

Safety devices such as bubble detectors and level detectors have been in use for more than 40 years and initially reduced the risks associated with gaseous emboli during cardiopulmonary bypass; however, the risks have not been eliminated. This research explored a new safety device designed to further reduce these risks: Flow Awareness Technology. This device visually alerts the perfusionist when the ratio of venous return does not equal the amount of arterial flow. To determine the efficacy of this device, 33 participants with no perfusion background were randomly assigned to Group A (flow awareness only), Group B (level detector only), or Group C (control). These participants were instructed to turn off the arterial pump when they noticed that the fluid in the venous reservoir had begun to drop or if their assigned safety device was triggered. The venous line was fully occluded at times unknown to the participants. These times coincided with before, during, or after times that the participants were expected to paper-chart known values. Each participant's amount of fluid lost (in milliliters) from the reservoir and reaction time (in seconds) to shut off the arterial roller pump were measured. Group A lost an average of 80.8 mL, Group B lost an average of 173.6 mL, and Group C lost an average of 140.3 mL. Average measured time for each group is as follows: Group A took 2.16 seconds, Group B took 4.31 seconds, and Group C took 4.09 seconds to shut off the arterial pump. Statistics support the hypothesis that Flow Awareness Technology significantly reduces the reaction time to an adverse event such as a sudden occlusion of the venous line, thus reducing the amount of fluid lost during such an event.


Assuntos
Ponte Cardiopulmonar , Embolia Aérea , Máquina Coração-Pulmão , Humanos , Oxigenadores , Equipamentos de Proteção
17.
Perfusion ; 34(2): 136-142, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30124127

RESUMO

INTRODUCTION: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system ("Dihead CPB") for application during coronary artery bypass grafting (CABG) and valve surgery. To strive for minimal hemolysis during Dihead CPB, we compared the hemolysis caused by three different suction systems and performed a clinical study with the newly applied suction system. MATERIALS & METHODS: We evaluated the hemolysis caused by roller-pump suction, the SmartSuction® Harmony® and wall suction systems with respect to suction speed and compared the systems by means of in vitro studies. A clinical study was also performed on 15 volunteers to assess hemolysis and the adequacy of the newly applied suction system with Dihead CPB. RESULTS: Pressure inside the suction cannula was -22.5 ± 0.1 mmHg at a maximum flow of 1.5 L/min for roller-pump suction and -43.4 ± 0.1 mmHg at -150 mmHg of the set vacuum pressure of wall suction. With the SmartSuction, the pressure inside the cannula varied from -76.3 ± 1.0 to -130.3 ± 1.5 mmHg, depending on suctioning conditions. Suction speed (to suction 50 ml of blood) was fastest with the SmartSuction (69.7 ± 3.58 s) whereas, with roller suction, it was 117.3 ± 8.47 s and with wall suction 96.9 ± 7.10 s. The SmartSuction had the highest hemolysis rate (2.00 ± 0.33%) vs. 0.61 ± 0.10% for roller suction and 0.41 ± 0.11% for wall suction (p<0.001). The clinical study with wall suction showed no significant increase in plasma free hemoglobin during or after CPB compared with before surgery. CONCLUSIONS: Wall suction had less hemolysis than roller suction or the SmartSuction in the in vitro study and the clinical study with wall suction showed efficient suction speed and acceptable hemolysis, suggesting that Dihead CPB with wall suction is feasible for CABG.


Assuntos
Ponte Cardiopulmonar/métodos , Máquina Coração-Pulmão/normas , Feminino , Hemólise , Humanos , Masculino , Pessoa de Meia-Idade
18.
J Extra Corpor Technol ; 50(4): 244-247, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30581232

RESUMO

Extracorporeal membrane oxygenation (ECMO) has become a powerful tool in the race to reverse failure to rescue events. Rapid implementation set the stage for the advent of the 30-day wet-priming storage as a standard practice. A recent alert regarding methylene blue (MB) unidirectional leach from patient's circulation through the oxygenator thermoplastic polyurethane (TPU) heat-exchanger membrane into the heater-cooler unit (HCU) water bath led us to believe that despite reassurances, the reverse process might be possible. To that effect, we performed a pilot in vitro experiment. We tested three adult ECMO sets (Adult Quadrox iD Oxygenator, Getinge, Doral, FL) probing for the transfer of MB between the water bath of a Sarns Dual Heater Cooler (Terumo Corporation, Ann Arbor, MI) and the circuit stored wet-primed for 30 days. In each test, 1,500 mg of reconstituted MB (HiMedia, Mumbai, India) were added to the 7.5 L of water in the HCU, circulated for 6 hours on which the water lines were disconnected and the setup was stored for 30 days. The primed circuit was tested for MB transfer at days 0, 13, and 30 by means of optical density (OD) at 665 nm and 26.5°C. Transference of MB from the HCU water bath into the ECMO circuit could be detected as early as day 13 after setup, achieving significant values by day 30 (median OD .019 (.014-.021). Expected OD if no diffusion present: 0. The complete separation of water interfaces between the patient's circuit and the HCU water bath may prove to be more dogma than fact when certain chemical substances are used in conjunction with TPU membrane oxygenators. Whether the transfer of substances is due to chemical processes or molecular weight needs further evaluation. Meanwhile, the use of chemicals for the cleaning of the HCU should be mindful of potential noxious effects.


Assuntos
Oxigenadores de Membrana , Máquina Coração-Pulmão , Temperatura Alta , Humanos , Poliuretanos
19.
Perfusion ; 33(4): 303-309, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29199541

RESUMO

BACKGROUND: During cardiopulmonary bypass (CPB) in children, anesthesia maintained by sevoflurane administered via the oxygenator is increasingly common. Anesthetic uptake and requirement may be influenced by the non-physiological conditions during hypothermic CPB. Narcotrend-processed EEG monitoring may, therefore, be useful to guide the administration of sevoflurane during this phase. OBJECTIVE: The objective of this prospective, clinical, observational study was to assess the correlation between body temperature, Narcotrend Index (NI) and administered sevoflurane in children during CPB. METHODS: Forty-four children aged 0 to 10 years undergoing hypothermic cardiac surgery were studied. On bypass, anesthesia was maintained with sevoflurane administered via the oxygenator of the heart-lung machine. Nasopharyngeal temperature, NI and minimum alveolar concentration (MAC) of sevoflurane were recorded in intervals of 10 minutes. Expiratory gas was sampled from the oxygenator's sole expiratory port via a separate connecting line and the MAC was measured by the agent analyzer of the anesthesia machine. RESULTS: Raw (r = 0.74) and corrected (r = 0.73) r-values show that narcosis depth (as indicated by NI) can primarily be explained by the interaction of MAC and temperature. The analysis of variance (without the interaction term) confirms the significant and independent association of both factors, MAC (p<0.004, 95%CI: 0.19 to 0.46) and temperature (p<0.0001, 95%CI: 0.68 to 0.78), with the NI. During hypothermia, sevoflurane had been reduced significantly (r = 0.41, p<0.0001, 95%CI: 0.33 to 0.48). CONCLUSION: Perfusionists and anesthetists should be aware of the results of processed electroencephalograph (EEG) monitoring during CPB. Sevoflurane requirements differ inter-individually; they may decrease during cooling and increase during rewarming. Therefore, it seems reasonable to include the results of processed EEG monitoring when administering sevoflurane during CPB in children, but further studies are necessary to confirm this thesis.


Assuntos
Anestésicos Inalatórios/uso terapêutico , Ponte Cardiopulmonar/métodos , Hipotermia Induzida/métodos , Éteres Metílicos/uso terapêutico , Anestésicos Inalatórios/administração & dosagem , Temperatura Corporal/efeitos dos fármacos , Criança , Pré-Escolar , Feminino , Máquina Coração-Pulmão , Humanos , Lactente , Recém-Nascido , Masculino , Éteres Metílicos/administração & dosagem , Monitorização Intraoperatória/métodos , Estudos Prospectivos , Sevoflurano
20.
Soc Stud Sci ; 48(4): 507-539, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30132745

RESUMO

In 1962, surgeons at two hospitals in Bombay used heart-lung machines to perform open-heart surgery. The devices that made this work possible had been developed in Minneapolis in 1955 and commercialized by 1957. However, restrictions on currency exchange and foreign imports made it difficult for surgeons in India to acquire this new technology. The two surgeons, Kersi Dastur and PK Sen, pursued different strategies to acquire the ideas, equipment, and tacit knowledge needed to make open-heart surgery work. While Dastur tapped Parsi networks that linked him to local manufacturing expertise, Sen took advantage of opportunities offered by the Rockefeller Foundation to access international training and medical device companies. Each experienced steep learning curves as they pursued the know-how needed to use the machines successfully in dogs and then patients. The establishment of open-heart surgery in India required the investment of substantial labor and resources. Specific local, national, and transnational interests motivated the efforts. Heart-lung machines, for instance, took on new meanings amid the nationalist politics of independent India: Even as surgeons sought imported machines, they and their allies assigned considerable value to 'indigenous' innovation. The confluence of the many interests that made Sen and Dastur's work possible facilitated the uneasy co-existence of conflicting judgments about the success or failure of this medical innovation.


Assuntos
Comércio , Máquina Coração-Pulmão/história , Tecnologia/história , Cirurgia Torácica/história , Animais , Cães , Máquina Coração-Pulmão/economia , Máquina Coração-Pulmão/estatística & dados numéricos , História do Século XX , Humanos , Índia , Invenções/história , Cirurgia Torácica/métodos , Procedimentos Cirúrgicos Torácicos/história , Procedimentos Cirúrgicos Torácicos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA