1.
Vet Surg ; 50(4): 758-766, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33687084

RESUMO

OBJECTIVE: To determine the influence of a custom 3D-printed guide for placement of cortical bone screws in the equine navicular bone. STUDY DESIGN: Ex vivo study. SAMPLE POPULATION: Eight pairs of normal adult equine forelimbs. METHODS: A 3.5 × 55 mm cortical screw was placed in the longitudinal axis of each intact navicular bone. Screws were placed with a 3D-printed guide (3D) in one bone and with a traditional aiming device (AD) in the contralateral bone within each pair. Duration of surgery and the number of fluoroscopy images were compared between techniques. Screw placement was subjectively evaluated by gross examination and scored by three boarded veterinary surgeons. RESULTS: The use of a 3D-printed guide reduced the duration of surgery by 6.6 min (±1.5 min) compared to traditional screw placement (20.7 min ± 4.8 min, p < .01). Fewer peri-operative fluoroscopic images were obtained when the 3D guide was used (18 images ± 2.6 images vs. 40 images ± 5.1, p < .01). No difference was detected in navicular screw placement. CONCLUSION: The use of a 3D guide decreased the time required to place screws and the number of intraoperative images taken without affecting screw placement in intact navicular bones. CLINICAL RELEVANCE: 3D-printed guides can aid in the study, practice, and execution of surgical procedures reducing surgical time and radiation exposure throughout the operative period achieving similar results to those obtained with a conventional approach.


Assuntos
Parafusos Ósseos/veterinária , Osso Cortical/cirurgia , Cavalos/cirurgia , Impressão Tridimensional , Cirurgia Veterinária/métodos , Ossos do Tarso/cirurgia , Animais , Parafusos Ósseos/estatística & dados numéricos , Cadáver , Feminino , Fluoroscopia/veterinária , Masculino , Cirurgia Veterinária/instrumentação , Cirurgia Veterinária/estatística & dados numéricos
2.
Arch Orthop Trauma Surg ; 140(8): 1047-1054, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31965281

RESUMO

BACKGROUND: Various internal fixation methods have been used to treat proximal femur fractures and occasionally the fixation material is removed. However, nationwide trends of hardware removals are not known. Thus, this study investigated the hardware removal rates after proximal femur fractures in Finland during 1997-2016. MATERIALS AND METHODS: Finnish adults aged 18 years or older in 1997-2016 formed the basic study population. From the National Hospital Discharge Register patients with trochanteric femur fracture treated with an intramedullary nail (IMN) or dynamic hip screw (DHS), and patients with femoral neck fracture treated with screw fixation, were included. Hardware removal and secondary prosthesis rates were assessed. RESULTS: Altogether 41,253 patients underwent proximal femoral fracture fixation surgery in Finland in 1997-2016. Of these, 16,152 were DHS surgery and 15,724 IMN surgery and 8491 underwent screw operation of femoral neck fracture. The total removal rates of DHS and IMN were 5.5% and 5.4%. The total removal rate of screw fixations of the femoral neck was higher, 18.5%. The total removal rates during the first 3 years after the IMN more than halved in 1997-2013, from 7.6% to 3.7%, whereas the removal rate of the DHS or screw fixation of femoral neck fractures did not show consistent trend. The rate of secondary prosthesis operations following DHS and IMN was low (1.8% for both). This was in clear contrast to the prosthesis rate following screw fixations of the femoral neck (7.2%). CONCLUSIONS: IMN operations largely replaced DHS operations in trochanteric fractures of the proximal femur in Finland in 1997-2016. The removal and secondary prosthesis rates of the DHS and IMN were clearly lower than the corresponding rates after screw fixations of the femoral neck fracture. LEVEL OF EVIDENCE: III, Epidemiologic study.


Assuntos
Parafusos Ósseos/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Fixação Interna de Fraturas , Fraturas do Quadril , Adolescente , Adulto , Fêmur/cirurgia , Finlândia , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/cirurgia , Humanos
3.
Acta Orthop Belg ; 86(2): 233-238, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33418612

RESUMO

The aim of this study is to assess if there is a difference in outcomes between a dynamic hip screw with or without an anti-rotation screw in the treatment of hip fractures. All patients with an intracapsular hip fracture who underwent dynamic hip screw osteosynthesis between January 2010 and December 2013 in three Dutch hospitals were reviewed. Minimal follow-up was one year. The study included a total of 364 patients. 24 patients were lost to follow-up and excluded. 297 (87.4%) were in the dynamic hip screw group and 43 (12.6%) in the dynamic hip with anti-rotation screw group. Direct comparison of patient characteristics of the two groups showed significant differences in age, sex, Garden classification and Pauwels classification. Patients operated with a dynamic hip screw and anti-rotation screw are significantly younger and their fractures are significantly more dislocated and steeper. To draw conclusions about differences in outcome, a randomised clinical trial should be performed.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Fratura-Luxação , Fixação Interna de Fraturas , Complicações Pós-Operatórias , Fatores Etários , Parafusos Ósseos/efeitos adversos , Parafusos Ósseos/classificação , Parafusos Ósseos/estatística & dados numéricos , Desenho de Equipamento , Feminino , Fraturas do Colo Femoral/diagnóstico , Fraturas do Colo Femoral/epidemiologia , Fratura-Luxação/diagnóstico , Fratura-Luxação/epidemiologia , Fratura-Luxação/genética , Fratura-Luxação/prevenção & controle , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação das Necessidades , Países Baixos/epidemiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Risco Ajustado/métodos , Fatores de Risco , Torção Mecânica
4.
J Shoulder Elbow Surg ; 28(3): 510-519, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30466818

RESUMO

BACKGROUND: Recent recalls of several commonly used elbow arthroplasty implants have prompted interest in the modes by which elbow implants fail and the timing of reports of these failures. METHODS: We reviewed the adverse event reports to the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database from 2012 to 2015 regarding elbow arthroplasty to determine the event date and the type of each adverse event. RESULTS: Among 179 total elbow adverse event reports, the most common modes of failure were implant dissociation (23%), loosening (22%), and infection (16%). The most common modes of failure among 58 radial head replacement reports were component dissociation (19%) and linkage screw failure (19%). The percentage distribution of adverse event types differed among different arthroplasty systems and from that reported in published reviews of elbow arthroplasty. Three implant recalls were implemented 2, 5, and 9 years after the first adverse event report in the MAUDE database. For 2 of the recalls, the first reports of the device failures were published 2 and 5 years after the first MAUDE reports. CONCLUSIONS: The MAUDE database is a publicly funded and publicly available means by which surgeons can identify adverse events for the prostheses they use before such information becomes available through journal publication or recall notification. In this study, MAUDE data revealed a higher relative frequency of mechanical dissociation of elbow implants than what has been represented in the literature. Early identification of these adverse events may help surgeons by informing their implant selection and surgical technique.


Assuntos
Artroplastia de Substituição do Cotovelo/estatística & dados numéricos , Prótese de Cotovelo/estatística & dados numéricos , Falha de Prótese/etiologia , Artroplastia de Substituição do Cotovelo/efeitos adversos , Parafusos Ósseos/efeitos adversos , Parafusos Ósseos/estatística & dados numéricos , Bases de Dados Factuais , Prótese de Cotovelo/efeitos adversos , Humanos , Disseminação de Informação , Recall de Dispositivo Médico , Fatores de Tempo , Estados Unidos , United States Food and Drug Administration
5.
BMC Musculoskelet Disord ; 19(1): 369, 2018 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-30314495

RESUMO

BACKGROUND: Hip fractures are a major worldwide public health problem and includes two main types of fractures: the intracapsular (cervical) and the extracapsular (trochanteric and subtrochanteric) fractures. The aim of this study on patients with trochanteric and subtrochanteric hip fractures was to describe the epidemiology, treatment and outcome in terms of mortality within the context of a large register study. METHODS: A descriptive epidemiological register study including patients registered in the national Swedish Fracture Register from January 2014 to December 2016. Inclusion criteria were all primary surgically treated traumatic non-pathological trochanteric and subtrochanteric femoral fractures in patients aged 18 years and above. Individual patient data (age, gender, injury location, injury cause, fracture type, treatment and timing of surgery) were retrieved from the register database. Mortality data was obtained via linkage to the Swedish Death Register. RESULTS: A total of 10,548 consecutive patients were identified and included in the study. The mean (±SD) age for all patients was 82 ± 11 years and the majority of the patients were females (69%). Most of the fractures were caused by a fall at the same level (83%) at the patients' accommodation (75%). Fractures were classified using the AO/OTA classification as 31-A1 in 29%, as 31-A2 in 49% and as 31-A3 in 22% of the cases. The most commonly used implant was a short antegrade intramedullary nail (42%), followed by a plate with sliding hip screw (37%). With increasing fracture complexity, the proportion of intramedullary nails was increasing, and also the use of long versus short nails. The majority of the patients were operated within 36 h (90%). There was a higher mortality at 30 days and 1 year for males, and for all those who were delayed to surgery > 36 h. CONCLUSION: Safety measures to prevent fall at elderly patient's accommodation might be a way to reduce the number of trochanteric and subtrochanteric hip fractures. Surgery as soon as possible without delay should be considered to reduce the mortality rate. The selection of surgical methods depends on the fracture complexity.


Assuntos
Acidentes por Quedas , Fixação Intramedular de Fraturas/métodos , Fraturas do Quadril/epidemiologia , Mortalidade/tendências , Sistema de Registros/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Pinos Ortopédicos/estatística & dados numéricos , Placas Ósseas/estatística & dados numéricos , Parafusos Ósseos/estatística & dados numéricos , Feminino , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Quadril/etiologia , Fraturas do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais , Suécia/epidemiologia , Tempo para o Tratamento , Adulto Jovem
6.
Bull Tokyo Dent Coll ; 59(2): 67-78, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29962423

RESUMO

The purpose of this study was to investigate factors involved in stress on locking mini-plate/screws used in orthognathic surgery based on patient-specific 3-dimensional finite element analysis. Data were obtained from 10 patients undergoing mandibular advancement by bilateral sagittal split ramus osteotomy. All underwent osteosynthesis with 2.0-mm titanium locking mini-plate/screws. A 3-dimensional finite element model of the mandible was created for each patient and each model subjected to the same loading conditions, which produced different stress values on locking mini-plate/screws. When the contact area of the proximal and distal bone segments was narrower and bone mineral density (BMD) lower, the von Mises stress values on the plate/screws were higher (contact area, p<0.01; BMD, p<0.05). The present results suggest that bone contact area and BMD should be considered as plate stress factors.


Assuntos
Análise de Elementos Finitos , Técnicas de Fixação da Arcada Osseodentária/instrumentação , Mandíbula/cirurgia , Avanço Mandibular/instrumentação , Osteotomia Sagital do Ramo Mandibular/instrumentação , Osteotomia Sagital do Ramo Mandibular/métodos , Osteotomia/instrumentação , Osteotomia/métodos , Adolescente , Adulto , Densidade Óssea , Placas Ósseas/estatística & dados numéricos , Parafusos Ósseos/estatística & dados numéricos , Simulação por Computador , Desenho de Equipamento , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Avanço Mandibular/métodos , Pessoa de Meia-Idade , Modelos Anatômicos , Procedimentos Cirúrgicos Ortognáticos/instrumentação , Procedimentos Cirúrgicos Ortognáticos/métodos , Estresse Mecânico , Titânio , Adulto Jovem
7.
Eur J Orthop Surg Traumatol ; 28(4): 607-613, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29273918

RESUMO

The term atypical femoral fractures most commonly occur in the subtrochanteric area. Concerns exist regarding the role of bisphosphonate treatment in their aetiology. Which surgical intervention provides the best outcome remains contentious. We reviewed all atypical subtrochanteric femoral fractures treated in Northern Ireland over 5 years, specifically investigating incidence, prodromal symptoms, association with bisphosphonates and optimal fixation methods. All subtrochanteric fractures treated in the region were identified and reviewed for atypical features. Case notes and imaging were then reviewed for each patient. A total of 364 subtrochanteric femoral fractures were identified during the 5-year study period. Twenty-six of these met the criteria for an atypical fracture (7%). Thirteen patients (50%) had presented with prodromal symptoms prior to complete fracture, six of which had radiological evidence of an incomplete fracture of the lateral cortex. Thirteen patients had a history of bisphosphonate treatment. All were treated operatively, with twenty-five cephalomedullary nails and one dynamic hip screw. Twenty-one patients had follow-up for greater than 2 months, nine of which (42.9%) achieved radiological union with a mean time to union of 297 days. Dynamically locked nails had a higher union rate than statically locked (80% versus 33.3%). Four patients required major revision surgery (15.4%). The quality of reduction was statistically significant in predicting need for revision. Atypical fractures often present with prodromal symptoms. Complete fractures are difficult to successfully manage with longer than expected times to union. Treatment with a dynamically locked, cephalomedullary with a good reduction provided the best results.


Assuntos
Fraturas do Quadril/epidemiologia , Idoso , Análise de Variância , Pinos Ortopédicos/estatística & dados numéricos , Parafusos Ósseos/estatística & dados numéricos , Feminino , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/estatística & dados numéricos , Fraturas do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Irlanda do Norte/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
8.
BMC Musculoskelet Disord ; 18(1): 322, 2017 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-28754114

RESUMO

BACKGROUND: Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. METHODS: Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. RESULTS: The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. CONCLUSIONS: The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.


Assuntos
Parafusos Ósseos/estatística & dados numéricos , Procedimentos Ortopédicos/instrumentação , Escoliose/cirurgia , Humanos , Torque
9.
BMC Musculoskelet Disord ; 18(1): 405, 2017 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-28950848

RESUMO

BACKGROUND: Intramedullary screw (IMS) fixation was wildly used in fifth metatarsal base fractures (FMBFs) and the results were satisfactory. However, in the comminuted osteoporosis or small displaced avulsion FMBFs, anatomical reduction and stable fixation could not be achieved with IMS. The Locking Compression Plate (LCP) distal ulna hook plate fixation was a novel alternative fixation method. The aim of this retrospective cohort study was to determine if LCP distal ulna hook plate fixation resulted in improved outcomes compared to the traditional IMS fixation in displaced avulsion FMBFs. METHODS: Of 43 patients with displaced avulsion FMBFs, 18 patients were treated with LCP distal ulna hook plate fixation and 25 were treated with IMS fixation. The patients were evaluated clinically and radiographically and followed up to 12 months. The surgery time, time for hospital stay, time for weight-bearing, time for bony union, time for return to daily life, pain relief, functional outcome and complications after treatment with LCP distal ulna hook plate fixation or IMS fixation were compared. The functional outcome was assessed by the AOFAS (American Orthopedic Foot and Ankle Society) mid-foot score at 3, 6, 9, and 12 months after surgery. Meanwhile, pain scores were obtained at 3, 6, 9, and 12 months after surgery. RESULTS: The two cohorts had similar baseline characteristics. Surgery time was less in LCP distal ulna hook plate fixation cohort compare to IMS fixation cohort (p < 0.0001). Time for partial weight-bearing (p < 0.0001) and full weight-bearing (p < 0.0001) also demonstrated significant improvements in patients with LCP distal ulna hook plate fixation compared to IMS fixation. Patients in the LCP distal ulna hook plate fixation cohort had significantly increased AOFAS at 9 months (p < 0.0001) and 12 months (p < 0.0001) after surgery compared to the IMS fixation cohort. CONCLUSION: In this retrospective cohort study, LCP distal ulna hook plate fixation as an alternative fixation method was better therapy for the displaced avulsion FMBFs compared to IMS fixation. LCP distal ulna hook plate fixation had a short surgery time and improved functional performance.


Assuntos
Parafusos Ósseos/estatística & dados numéricos , Fixação Interna de Fraturas/métodos , Fratura Avulsão/cirurgia , Fraturas Ósseas/cirurgia , Ossos do Metatarso/cirurgia , Instrumentos Cirúrgicos/estatística & dados numéricos , Adulto , Placas Ósseas/estatística & dados numéricos , Estudos de Coortes , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Fratura Avulsão/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Ossos do Metatarso/diagnóstico por imagem , Ossos do Metatarso/lesões , Estudos Retrospectivos , Ulna/diagnóstico por imagem , Ulna/cirurgia
10.
Neurosurg Focus ; 43(2): E6, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28760031

RESUMO

OBJECTIVE The objective of this study was to describe the use of a minimally invasive surgical treatment of lumbar spondylolysis in athletes by a fluoroscopically guided direct pars screw placement with recombinant human bone morphogenetic protein-2 (rhBMP-2) and to report on clinical and radiographic outcomes. METHODS A retrospective review was conducted of all patients treated surgically for lumbar spondylolysis via a minimally invasive direct pars repair with cannulated screws. Demographic information, clinical features of presentation, perioperative and intraoperative radiographic imaging, and postoperative data were collected. A 1-cm midline incision was performed for the placement of bilateral pars screws utilizing biplanar fluoroscopy, followed by placement of a fully threaded 4.0-mm-diameter titanium cannulated screw. A tubular table-mounted retractor was utilized for direct pars fracture visualization and debridement through a separate incision. The now-visualized pars fracture could then be decorticated, with care taken not to damage the titanium screw when using a high-speed drill. Local bone obtained from the curettage was then placed in the defect with 1.05 mg rhBMP-2 divided equally between the bilateral pars defects. RESULTS Nine patients were identified (mean age 17.7 ± 3.42 years, range 14-25 years; 6 male and 3 female). All patients had bilateral pars fractures of L-4 (n = 4) or L-5 (n = 5). The mean duration of preoperative symptoms was 17.22 ± 13.2 months (range 9-48 months). The mean operative duration was 189 ± 29 minutes (range 151-228 minutes). The mean intraoperative blood loss was 17.5 ± 10 ml (range 10-30 ml). Radiographic follow-up was available in all cases; the mean length of time from surgery to the most recent imaging study was 30.8 ± 23.3 months (range 3-59 months). The mean hospital length of stay was 1.13 ± 0.35 days (range 1-2 days). There were no intraoperative complications. CONCLUSIONS Lumbar spondylolysis treatment with a minimally invasive direct pars repair is a safe and technically feasible option that minimizes muscle and soft-tissue dissection, which may particularly benefit adolescent patients with a desire to return to a high level of physical activity.


Assuntos
Proteína Morfogenética Óssea 2/administração & dosagem , Parafusos Ósseos , Vértebras Lombares/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Espondilólise/cirurgia , Fator de Crescimento Transformador beta/administração & dosagem , Adolescente , Parafusos Ósseos/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Vértebras Lombares/diagnóstico por imagem , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Proteínas Recombinantes/administração & dosagem , Estudos Retrospectivos , Espondilólise/diagnóstico por imagem , Adulto Jovem
11.
Neurosurg Focus ; 43(2): E4, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28760037

RESUMO

Elderly patients with diffuse idiopathic skeletal hyperostosis are at high risk for falls, and 3-column unstable fractures present multiple challenges. Unstable fractures across the cervicothoracic junction are associated with significant morbidity and require fixation, which is commonly performed through a posterior open or percutaneous approach. The authors describe a novel, navigated, mini-open anterior approach using intraoperative cone-beam CT scanning to place lag screws followed by an anterior plate in a 97-year-old patient. This approach is less invasive and faster than an open posterior approach and can be considered as an option for management of cervicothoracic junction fractures in elderly patients with high perioperative risk profile who cannot tolerate being placed prone during surgery.


Assuntos
Vértebras Cervicais/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Idoso de 80 Anos ou mais , Placas Ósseas/estatística & dados numéricos , Parafusos Ósseos/estatística & dados numéricos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/lesões , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Fraturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/lesões
12.
Surg Technol Int ; 30: 490-495, 2017 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-28693046

RESUMO

INTRODUCTION: Drill bit tip plunging past the far cortex places critical anatomical structures at risk. This study measured plunging past the far cortex based on level of training. The time required for screw placement when a depth gauge was used to measure bone tunnel depth was compared to the time required for screw placement when bone tunnel depth was measured in real time. MATERIALS AND METHODS: Thirty orthopedic surgery staff with 1-37 years of experience applied 10-hole plates to cadaveric limbs. Procedures were performed using two different drilling systems. Time and plunge depth were recorded. RESULTS: Penetration past the far cortex ranged from an average of 11.9 mm in the novice group to an average of 6.1 mm in the experienced group (P <0.001). The time required to drill and place a screw decreased by an average of 14 seconds per screw when depth gauge use was eliminated. CONCLUSIONS: Penetration past the far cortex occurred at all levels of training, but decreased with increased levels of experience. Real time measurement of bone tunnel length decreased total drilling time. The time saved with real time measurement decreased with increased level of experience.


Assuntos
Parafusos Ósseos/estatística & dados numéricos , Procedimentos Ortopédicos , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/cirurgia , Humanos , Pessoa de Meia-Idade , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/métodos , Procedimentos Ortopédicos/estatística & dados numéricos , Fatores de Tempo
13.
Stereotact Funct Neurosurg ; 94(5): 342-347, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27723656

RESUMO

BACKGROUND: The purpose of our report is to describe an innovative system used for mandibular immobilization during Gamma Knife surgery (GKS) procedures. It is based on an approach originally developed in Marseille in extracranial lesions, close to or involving the mandible, which may imply a certain degree of movement during the therapeutic image acquisitions and/or GKS treatment. METHODS: The maxillofacial surgeon applied bone titanium self-tapping monocortical screws (4; 2 mm diameter, 10 mm length) between roots of the teeth in the fixed gingiva (upper and lower maxillae) the day before GKS (local anesthesia, 5-10 min time). Two rubber bands were sufficient for the desired tension required to undergo GKS. We further proceeded with application of the Leksell stereotactic G frame and carried out the usual GKS procedure. RESULTS: The mean follow-up period was 2.3 years (range 0.6-3). Three patients have been treated with this approach: 2 cases with extracranial trigeminal schwannomas involving the mandibular branch, with decrease in tumor size on MR follow-up; 1 case with residual paracondylian mandibular arteriovenous malformation following partial embolization, completely obliterated at 7 months (digital subtraction angiography programmed 1 year after treatment). CONCLUSIONS: Jaw immobilization appears to be a quick, minimally invasive, safe and accurate adjunctive technique to enhance GKS targeting precision.


Assuntos
Malformações Arteriovenosas/cirurgia , Invenções , Neoplasias Mandibulares/cirurgia , Neurilemoma/cirurgia , Radiocirurgia/métodos , Doenças do Nervo Trigêmeo/cirurgia , Adulto , Malformações Arteriovenosas/diagnóstico por imagem , Parafusos Ósseos/estatística & dados numéricos , Feminino , Humanos , Imobilização/instrumentação , Imobilização/métodos , Arcada Osseodentária/diagnóstico por imagem , Masculino , Neoplasias Mandibulares/diagnóstico por imagem , Pessoa de Meia-Idade , Neurilemoma/diagnóstico por imagem , Procedimentos Cirúrgicos Ortognáticos , Radiocirurgia/instrumentação , Doenças do Nervo Trigêmeo/diagnóstico por imagem
14.
J Arthroplasty ; 31(1): 156-61, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26260783

RESUMO

Screws, pegs and hydroxyapatite-coating are used to enhance the primary stability of uncemented cups. We present a 14-year follow-up of 48 hips randomized to four groups: press-fit only, press-fit plus screws, press-fit plus pegs and hydroxyapatite-coated cups. Radiostereometric migration measurements showed equally good stability regardless cup augmentation. The mean wear rate was high, 0.21 mm/year, with no differences between the groups. Seven hips had radiographical osteolysis but only in hips with augmented cups. Cups without screw-holes compared with cups with screw-holes resulted in better clinical outcome at the 14-year follow-up. Thus, augmentation of uncemented cups with screws, pegs, or hydroxyapatite did not appear to improve the long-term stability compared with press-fit only.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Prótese de Quadril/estatística & dados numéricos , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Parafusos Ósseos/estatística & dados numéricos , Durapatita , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Análise Radioestereométrica
15.
J Pediatr Orthop ; 36(3): e27-37, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-25929770

RESUMO

BACKGROUND: The most widely used treatment for slipped capital femoral epiphysis (SCFE) is in situ fixation. In an attempt to reduce the chances of impingement, osteoarthritis, and osteonecrosis, surgeons have started adopting newer surgical techniques. The purpose of this study was to determine the current pattern of treating SCFE. METHODS: A questionnaire was sent electronically to all of the members of the Pediatric Orthopaedic Society of North America. The data were analyzed dividing surgeons into academic versus private practice, years of practice, and number of SCFEs treated per year. RESULTS: Of 990 members, 277 (28%) responded to the survey.Type of practice (academic, n=181 vs. private, n=51): For unstable severe SCFE, surgeons in academic practice use the surgical hip dislocation (SHD) approach significantly more frequently (35.7% vs. 14.9%; P=0.02). A radiolucent table is used significantly more frequently in academic practice for both stable (50.6% vs. 29.8%; P=0.01) and unstable (39.6% vs. 15.2%; P=0.002) SCFE. Fully threaded cannulated screws (44.4% vs. 27.1%; P=0.03), open capsular decompression (63.9% vs. 32.4%; P=0.001), contralateral pinning (79% vs. 58.7%; P=0.005), and postoperative magnetic resonance imaging (MRI) (15.5% vs. 3.9%; P=0.03) are significantly more frequent in academic practice.Years of practice (≤15 y, n=124 vs. >15 y, n=140): For severe stable SCFE, surgeons practicing for ≤15 years do acute osteotomies significantly less frequently (1.8% vs. 9%; P=0.004) and perform SHD significantly more frequently (20.2% vs. 8.2%; P=0.004). For unstable moderate SCFE, SHD is utilized significantly more frequently by surgeons ≤15 years in practice (29.8% vs. 16.5%; P=0.04). Bilateral frog-leg lateral views (86.4% vs. 73.7%; P=0.04), preoperative MRI (36.1% vs. 20.6%; P=0.006), open capsular decompression (69.3% vs. 51.7%; P=0.01) are significantly more frequent among surgeons ≤15 years in practice.Number of SCFE treated per year (<10, n=129 vs. ≥10, n=136): For unstable severe SCFE, surgeons treating ≥10/y perform SHD significantly more frequently (38.6% vs. 26.1%; P=0.02) and do in situ fixation with manual reduction significantly less frequently (11.8% vs. 21.8%; P=0.02). Radiolucent table (54.3% vs. 38%; P=0.01), 7.5 mm screw versus 6.5 mm (62% vs. 45.4%; P=0.01), contralateral pinning (78.9% vs. 67.8%; P=0.04), postoperative MRI (17.6% vs. 9.3%; P=0.04), and postoperative computed tomography (14.7% vs. 7%; 0.04) are significantly more frequent among surgeons doing ≥10/y. Elective implant removal is more common among surgeons treating <10/y (16.2% vs. 6.9%; P=0.02). CONCLUSIONS: Treatment of SCFE varies significantly depending on the surgeon's type of practice, years in practice, and numbers treated per year. Surgeons in academic practice, surgeons with ≤15 years in practice, and surgeons treating greater number of SCFEs are more likely to use SHD to acutely reduce the slip.


Assuntos
Procedimentos Ortopédicos/métodos , Padrões de Prática Médica/estatística & dados numéricos , Escorregamento das Epífises Proximais do Fêmur/cirurgia , Centros Médicos Acadêmicos/estatística & dados numéricos , Parafusos Ósseos/estatística & dados numéricos , Criança , Competência Clínica , Descompressão Cirúrgica/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Feminino , Luxação do Quadril , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Procedimentos Ortopédicos/instrumentação , Procedimentos Ortopédicos/estatística & dados numéricos , Osteotomia/estatística & dados numéricos , Prática Privada/estatística & dados numéricos , Inquéritos e Questionários , Tomografia Computadorizada por Raios X
16.
Int Orthop ; 40(6): 1179-86, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26686497

RESUMO

PURPOSE: To outline a management principle for the combined atlas (C1)-axis (C2) fractures and assess its therapeutic effects. METHODS: Forty-one patients with combined C1-C2 fractures were treated according to their C2 fracture types. Non-operative external immobilization in the form of a cervical collar or halo vest was used in 22 patients. Early posterior pedicle screw fixations were performed in 19 patients whose fractures had a combination of any of the three conditions: an atlantodens interval (ADI) ≥ 5 mm, lateral mass displacement (LMD) > 7 mm, and/or C2-C3 angulation > 11°. Thirty-nine patients were followed up regularly with an average of 19.3 months (range, 12 to 45 months). Clinical and radiographic data were then collected and compared. RESULTS: At three months following treatment, patients' visual analog scale (VAS), Neck Disability Index (NDI), American Spinal Injury Association (ASIA) scale, and Frankel grades were all significantly improved when compared to pretreatment. These results indicated that the cervical collar, halo vest, and posterior pedicle screw fixation approaches were all able to effectively treat cases of combined C1-C2 fractures. One patient in the non-surgical group developed nonunion which required late surgical treatment and one patient had pin site infection in the non-surgical group (2/22), while there were three minor complications in the surgical group. CONCLUSION: We propose a management principle that bases the treatment of a combined C1-C2 fracture on the nature of the C2 fracture. This treatment strategy has yielded promising results as a satisfactory means for the management of combined C1-C2 fractures.


Assuntos
Parafusos Ósseos/estatística & dados numéricos , Vértebras Cervicais/lesões , Fraturas da Coluna Vertebral/terapia , Contenções/estatística & dados numéricos , Adulto , Idoso , Parafusos Ósseos/efeitos adversos , Vértebras Cervicais/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Fusão Vertebral/métodos , Contenções/efeitos adversos , Adulto Jovem
17.
Vet Surg ; 45(8): 1025-1033, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27685761

RESUMO

OBJECTIVE: To compare reduction of type III distal phalangeal fractures using 4.5 and 5.5 mm cortical screws placed in lag fashion and an intact hoof capsule model. STUDY DESIGN: Cadaveric experimental study. SAMPLE POPULATION: Hooves from 12 adult horses (n=24). METHODS: Sagittal fractures were created in pairs of distal phalanges after distal interphalangeal joint disarticulation and were reduced with either 4.5 or 5.5 mm cortical screws placed in lag fashion. Contralateral phalanges served as non-reduced controls. Fracture reduction following screw placement was assessed by comparing pre-reduction and post-reduction fracture gap measurements from radiographs using paired t-tests. Effects of incremental loading (0, 135, 270, 540, 800, 1070, and 1335 kg) on fracture gaps in 6 phalanges reduced with 4.5 mm screws and 5 phalanges reduced with 5.5 mm screws were measured from fluoroscopic images and assessed by 2-way ANOVA. Significance was set at P<.05. RESULTS: Type III distal phalanx fractures were reliably created. Only 5.5 mm cortical screws, not 4.5 mm screws, significantly reduced fracture gaps and constrained fracture gap expansion 3 cm distal to the articular surface. Compressive loading closed the fracture gaps at the articular surface in both non-reduced control groups and those reduced with either 5.5 or 4.5 mm screws. CONCLUSION: The 5.5 mm cortical screws were more effective than 4.5 mm screws in reducing type III distal phalanx fractures and restricting distal fracture gap expansion under load.


Assuntos
Parafusos Ósseos/veterinária , Fixação de Fratura/veterinária , Fraturas Ósseas/veterinária , Cavalos/lesões , Cavalos/cirurgia , Falanges dos Dedos do Pé/cirurgia , Animais , Parafusos Ósseos/estatística & dados numéricos , Cadáver , Feminino , Fixação de Fratura/métodos , Fraturas Ósseas/cirurgia , Casco e Garras/cirurgia , Masculino
18.
Artigo em Inglês | MEDLINE | ID: mdl-27167421

RESUMO

UNLABELLED: PURPOSE OF THE STUDY The aim of this prospective study; The Trauma Assisted Discharge Scheme (TADS), was to set up a new model of postoperative care for patients following a fractured hip, addressing the need for efficiency, cost effectiveness and meeting local demand. MATERIAL AND METHODS All patients with hip fractures between December 2010 and December 2011, meeting the TADS inclusion criteria were enrolled in the study. Innovative use of staff within existing budgets helped create a TAD team who with the use of defined patient goals and a link nurse provided a seamless transition from acute to community services. RESULTS One hundred and sixteen patients followed the TADS pathway; the majority aged 80-89 years and independent prior to falling. A total of 35 patients underwent dynamic hip screw fixation; 55 hemiarthroplasty, 11 total hip replacement and 11 cannulated screw fixation. The average length of in-hospital stay was 8.6 nights. The TADS reduced the average length of stay by 4.78 days. CONCLUSION TADS has the potential to be used as a model of care in other specialities and is easily transferable to the wider NHS. KEY WORDS: continuous quality improvement, quality improvement, surgery, cost-effectiveness, ambulatory care.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Fixação Interna de Fraturas/estatística & dados numéricos , Hemiartroplastia/estatística & dados numéricos , Fraturas do Quadril/cirurgia , Tempo de Internação/tendências , Idoso de 80 Anos ou mais , Artroplastia de Quadril/economia , Parafusos Ósseos/estatística & dados numéricos , Análise Custo-Benefício , Feminino , Fixação Interna de Fraturas/economia , Hemiartroplastia/economia , Fraturas do Quadril/economia , Humanos , Masculino , Cuidados Pós-Operatórios , Estudos Prospectivos , Resultado do Tratamento
19.
J Oral Maxillofac Surg ; 73(1): 158-61, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25315307

RESUMO

PURPOSE: The purpose of this study was to determine the rate of infection after bilateral sagittal split osteotomy. MATERIALS AND METHODS: The investigators implemented a retrospective case series study. To be included in this study, patients needed to have a complete medical chart and a postoperative follow-up of at least 3 months. The outcome variable was postoperative infections. The predicator variables were type of surgery, medical comorbidities, third molar extraction, smoking, type of fixation, and antibiotic prophylaxis. Descriptive and bivariate statistics were computed, and significance was set at P < .05. Multivariate analyses were performed with logistic regression. RESULTS: The sample was composed of 336 patients with ages ranging from 13 to 65 years (27.2 ± 10.6). The rate of infection was 11.3%, and plates, screws, or both were removed in 10 patients (3%). There was a statistically significant association between age and infections (odds ratio, 1.04; 95% CI, 1.01-1.07; P = .02). CONCLUSIONS: The results of this study suggest that infection after bilateral sagittal split osteotomy is within normal range for a clean-contaminated procedure. Rigid fixation of the osteotomy may decrease the need for hardware removal.


Assuntos
Osteotomia Sagital do Ramo Mandibular/estatística & dados numéricos , Infecção da Ferida Cirúrgica/epidemiologia , Adolescente , Adulto , Fatores Etários , Idoso , Antibioticoprofilaxia/estatística & dados numéricos , Placas Ósseas/estatística & dados numéricos , Parafusos Ósseos/estatística & dados numéricos , Estudos de Coortes , Remoção de Dispositivo/estatística & dados numéricos , Feminino , Seguimentos , Mentoplastia/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Dente Serotino/cirurgia , Osteotomia de Le Fort/estatística & dados numéricos , Quebeque/epidemiologia , Estudos Retrospectivos , Fumar/epidemiologia , Extração Dentária/estatística & dados numéricos , Resultado do Tratamento , Adulto Jovem
20.
J Hand Surg Am ; 40(6): 1124-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25840479

RESUMO

PURPOSE: To compare 2- versus 3-screw fixation for oblique fractures of the proximal phalanx in a cadaver model that simulates active finger motion. METHODS: We experimentally cut the proximal phalanges of the index, middle, and ring fingers of 9 cadaveric hands. Five fingers were assigned to a control group with no fixation, and 22 were fixed with either 2 or 3 lag screws. One digit was excluded because of iatrogenic fracture during preparation. The fingers were fitted with a differential variable reluctance transducer that measured maximum interfragment displacement while the fingers were subjected to 2,000 full flexion and extension cycles to simulate a 6-week active motion protocol. RESULTS: Analysis of variance revealed a significant difference between the control group and both the 2- and the 3-screw group. The 2- and 3-screw group average displacements were not significantly different. Both of these groups were equivalent with a power of 90%. CONCLUSIONS: Biomechanical stability during simulated active motion protocol did not differ in simulated proximal phalanx fractures treated with 2 lag screws or 3. CLINICAL RELEVANCE: Fracture fixation using 2 screws may be more cost and time effective and, therefore, more attractive to the surgeon, even when 3 screws can be placed. Furthermore, surgeons may consider using 2 screws rather than resorting to plate fixation when 3-screw fixation is not possible for these types of fractures.


Assuntos
Parafusos Ósseos/estatística & dados numéricos , Falanges dos Dedos da Mão/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Falanges dos Dedos da Mão/lesões , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade