Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 967
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Urol ; 211(3): 445-454, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38134235

RESUMO

PURPOSE: There are limited data on ablation effects of thulium fiber laser (TFL) settings with varying stone composition. Similarly, little is known surrounding the photothermal effects of TFL lithotripsy regarding the chemical and structural changes after visible char formation. We aim to understand the TFL's ablative efficiency across various stone types and laser settings, while simultaneously investigating the photothermal effects of TFL lithotripsy. MATERIALS AND METHODS: Human specimens of calcium oxalate monohydrate, calcium oxalate dihydrate, uric acid, struvite, cystine, carbonate apatite, and brushite stones were ablated using 13 prespecified settings with the Coloplast TFL Drive. Pre- and postablation mass, ablation time, and total energy were recorded. Qualitative ablative observations were recorded at 1-minute intervals with photographs and gross description. Samples were analyzed with Fourier-transform infrared spectroscopy pre- and postablation and electron microscopy postablation to assess the photothermal effects of TFL. RESULTS: Across all settings and stone types, 0.05 J × 1000 Hz was the best numerically efficient ablation setting. When selected for more clinically relevant laser settings (ie, 10-20 W), 0.2 J × 100 Hz, short pulse was the most numerically efficient setting for calcium oxalate dihydrate, cystine, and struvite stones. Calcium oxalate monohydrate ablated with the best numerical efficiency at 0.4 J × 40 Hz, short pulse. Uric acid and carbonate apatite stones ablated with the best numerical efficiency at 0.3 J × 60 Hz, short pulse. Brushite stones ablated with the best numerical efficiency at 0.5 J × 30 Hz, short pulse. Pulse duration impacted ablation effectiveness greatly with 6/8 (75%) of inadequate ablations occurring in medium or long pulse settings. The average percent of mass lost during ablation was 57%; cystine stones averaged the highest percent mass lost at 71%. Charring was observed in 36/91 (40%) specimens. Charring was most often seen in uric acid, cystine, and brushite stones across all laser settings. Electron microscopy of char demonstrated a porous melting effect different to that of brittle fracture. Fourier-transform infrared spectroscopy of brushite char demonstrated a chemical composition change to amorphous calcium phosphate. CONCLUSIONS: We describe the optimal ablation settings based on stone composition, which may guide urologists towards more stone-specific care when using thulium laser for treating renal stones (lower energy settings would be safer for ureteral stones). For patients with unknown stone composition, lasers can be preset to target common stone types or adjusted based on visual cues. We recommend using short pulse for all TFL lithotripsy of calculi and altering the settings based on visual cues and efficiency to minimize the charring, an effect which can make the stone refractory to further dusting and fragmentation.


Assuntos
Apatitas , Fosfatos de Cálcio , Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Cálculos Urinários/cirurgia , Cálculos Urinários/química , Túlio/química , Estruvita , Cistina , Ácido Úrico , Cálculos Renais/terapia , Lasers , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico
2.
BJU Int ; 134(2): 276-282, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38797721

RESUMO

OBJECTIVES: To address the paucity of literature comparing outcomes achieved with utilisation of the high-power holmium:yttrium-aluminium-garnet (Ho:YAG) laser with MOSES technology vs those achieved with the thulium fibre laser (TFL) in mini-percutaneous nephrolithotomy (PCNL). METHODS: A retrospective review was performed of patients undergoing supine mini-PCNL between August 2021 and May 2023. Exclusion criteria were urinary diversion, simultaneous utilisation of >1 laser platform, use of any other form of fragmentation, and ureteric stones. The Ho:YAG platform (Lumenis Pulse P120H™ with MOSES technology, 120W; Boston Scientific®) and the TFL (Soltive SuperPulsed Thulium Fibre [SPTF], 60W; Olympus®) were compared. Data on stone-free rate (SFR) were determined by computed tomography performed on the first postoperative day and presented as absence of stone fragments, no fragments larger than 2 mm, or no fragments larger than 4 mm. RESULTS: A total of 100 patients met the inclusion criteria, 51 mini-PCNLs with the Ho:YAG laser and 49 with the SPTF laser. No significant differences in demographics or stone characteristics were detected between the two groups. The Ho:YAG laser utilised less energy and time, resulting in higher ablation efficiency (P < 0.05) and less total operating time (P < 0.05). Overall, there was no difference in SFR in any category between the Ho:YAG group and the SPTF group (no fragments: relative risk [RR] 0.81, 95% confidence interval [CI] 0.59-1.12, P = 0.21; fragments <2 mm: RR 0.86, 95% CI 0.67-1.10, P = 0.23; fragments <4 mm: RR 0.96, 95% CI 0.80-1.15, P = 0.67). CONCLUSIONS: Although we observed an equivalent postoperative SFR, this study supports a shorter operating time and greater intra-operative laser efficiency with the Ho:YAG laser over the SPTF laser in mini-PCNL.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Nefrolitotomia Percutânea , Túlio , Humanos , Feminino , Lasers de Estado Sólido/uso terapêutico , Masculino , Nefrolitotomia Percutânea/métodos , Nefrolitotomia Percutânea/instrumentação , Túlio/uso terapêutico , Estudos Retrospectivos , Pessoa de Meia-Idade , Cálculos Renais/cirurgia , Adulto , Resultado do Tratamento , Decúbito Dorsal , Idoso , Litotripsia a Laser/métodos , Litotripsia a Laser/instrumentação
3.
BJU Int ; 133(2): 223-230, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37942684

RESUMO

OBJECTIVES: To explore the optimal laser settings and treatment strategies for thulium fibre laser (TFL) lithotripsy, namely, those with the highest treatment efficiency, lowest thermal injury risk, and shortest procedure time. MATERIALS AND METHODS: An in vitro kidney model was used to assess the efficacy of TFL lithotripsy in the upper calyx. Stone ablation experiments were performed on BegoStone phantoms at different combinations of pulse energy (EP ) and frequency (F) to determine the optimal settings. Temperature changes and thermal injury risks were monitored using embedded thermocouples. Experiments were also performed on calcium oxalate monohydrate (COM) stones to validate the optimal settings. RESULTS: High EP /low F settings demonstrated superior treatment efficiency compared to low EP /high F settings using the same power. Specifically, 0.8 J/12 Hz was the optimal setting, resulting in a twofold increase in treatment efficiency, a 39% reduction in energy expenditure per unit of ablated stone mass, a 35% reduction in residual fragments, and a 36% reduction in total procedure time compared to the 0.2 J/50 Hz setting for COM stones. Thermal injury risk assessment indicated that 10 W power settings with high EP /low F combinations remained below the threshold for tissue injury, while higher power settings (>10 W) consistently exceeded the safety threshold. CONCLUSIONS: Our findings suggest that high EP /low F settings, such as 0.8 J/12 Hz, are optimal for TFL lithotripsy in the treatment of COM stones. These settings demonstrated significantly improved treatment efficiency with reduced residual fragments compared to conventional settings while keeping the thermal dose below the injury threshold. This study highlights the importance of using the high EP /low F combination with low power settings, which maximizes treatment efficiency and minimizes potential thermal injury. Further studies are warranted to determine the optimal settings for TFL for treating kidney stones with different compositions.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Túlio , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Cálculos Renais/terapia , Rim
4.
World J Urol ; 42(1): 79, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353743

RESUMO

PURPOSE: To identify laser settings and limits applied by experts during laser vaporization (vapBT) and laser en-bloc resection of bladder tumors (ERBT) and to identify preventive measures to reduce complications. METHODS: After a focused literature search to identify relevant questions, we conducted a survey (57 questions) which was sent to laser experts. The expert selection was based on clinical experience and scientific contribution. Participants were asked for used laser types, typical laser settings during specific scenarios, and preventive measures applied during surgery. Settings for a maximum of 2 different lasers for each scenario were possible. Responses and settings were compared among the reported laser types. RESULTS: Twenty-three of 29 (79.3%) invited experts completed the survey. Thulium fiber laser (TFL) is the most common laser (57%), followed by Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) (48%), continuous wave (cw) Thulium:Yttrium-Aluminium-Garnet (Tm:YAG) (26%), and pulsed Tm:YAG (13%). Experts prefer ERBT (91.3%) to vapBT (8.7%); however, relevant limitations such as tumor size, number, and anatomical tumor location exist. Laser settings were generally comparable; however, we could find significant differences between the laser sources for lateral wall ERBT (p = 0.028) and standard ERBT (p = 0.033), with cwTm:YAG and pulsed Tm:YAG being operated in higher power modes when compared to TFL and Ho:YAG. Experts prefer long pulse modes for Ho:YAG and short pulse modes for TFL lasers. CONCLUSION: TFL seems to have replaced Ho:YAG and Tm:YAG. Most laser settings do not differ significantly among laser sources. For experts, continuous flow irrigation is the most commonly applied measure to reduce complications.


Assuntos
Alumínio , Túlio , Neoplasias da Bexiga Urinária , Ítrio , Humanos , Túlio/uso terapêutico , Neoplasias da Bexiga Urinária/cirurgia , Lasers , Tecnologia
5.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613608

RESUMO

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Assuntos
Cálculos Renais , Litotripsia , Cálculos Ureterais , Humanos , Hólmio , Túlio , Ureteroscopia , Estudos Prospectivos , Cálculos Renais/cirurgia , Lasers
6.
World J Urol ; 42(1): 374, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38871959

RESUMO

PURPOSE: To compare the efficacy and safety of Holmium laser enucleation of the prostate (HoLEP), Thulium laser enucleation of prostate (ThuLEP) and Thulium fibre laser enucleation of prostate (ThuFLEP) by performing propensity score matched analysis (PSM). METHODS: We retrospectively analysed the patients who underwent HoLEP (Group 1, n = 696), ThuLEP (Group 2, n = 146) and ThuFLEP (Group 3, n = 193) surgery because of benign prostatic obstruction (BPO). A 1:1:1 HoLEP: ThuLEP: ThuFLEP group matching was performed using PSM analysis. Perioperative, postoperative functional outcomes and complications were analysed and compared. RESULTS: We observed significant improvement in functional parameters regarding IPSS, Qmax, PVR and quality of life in all groups compared to baseline values at the 1st, 6th and 12th postoperative months. There was no significant difference between different laser types in terms of urge (UUI) and stress urinary incontinence (SUI) at 1st postoperative month. In all three groups, no patient had postoperative SUI or UUI at 6th and 12th postoperative months. In addition, no significant difference was observed between laser types in terms of postoperative complications. CONCLUSION: HoLEP, ThuLEP and ThuFLEP are safe and effective LEP methods with improvement in functional parameters and low complication rates. Similar results in terms of functional outcomes and complications clearly show that these surgeries are alternatives to each other for the patients with BPO. Experts' opinions, practices and enucleation techniques should also be taken into consideration when choosing a laser for BPO surgery.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Pontuação de Propensão , Prostatectomia , Hiperplasia Prostática , Túlio , Humanos , Masculino , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/complicações , Estudos Retrospectivos , Lasers de Estado Sólido/uso terapêutico , Idoso , Túlio/uso terapêutico , Terapia a Laser/métodos , Pessoa de Meia-Idade , Prostatectomia/métodos , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Qualidade de Vida
7.
World J Urol ; 42(1): 265, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38676756

RESUMO

INTRODUCTION AND OBJECTIVES: To compare the perioperative and functional outcomes of low-power and high-power thulium:YAG VapoEnucleation (ThuVEP) of the prostate for the treatment of large-volume benign prostatic hyperplasia (BPH) (> 80 ml). PATIENTS AND METHODS: A prospective analysis of 80 patients with symptomatic BPO and prostatic enlargement (more than 80 ml) was conducted. They were divided randomly into two groups (40 patients in each group). One group was treated with low-power ThuVEP, and the other group was treated with high-power ThuVEP. All patients were assessed preoperatively and early postoperatively, and 12-month follow-up data were analyzed. The complications were noted and classified according to the modified Clavien classification system. RESULTS: The mean age at surgery was 68 (± 6.1) years, and the mean prostate volume was 112 (± 20.1) cc, and there were no differences between the groups (p = 0.457). The mean operative time was 88.4 ± 11.79 min for group A and 93.4 ± 16.34 min for group B, while the mean enucleation time was 59.68 ± 7.24 min for group A and 63.13 ± 10.75 min for group B. There were no significant differences between the groups regarding catheterization time and postoperative stay. The quality of life (QoL), International Prostate Symptom Score (IPSS), maximum urinary flow rate (Qmax), postvoiding residual urine (PVR), and prostate volume improved significantly after treatment and were not significantly different between those treated with the different energies. The incidence of complications was low and did not differ between both the groups. CONCLUSION: Low-power ThuVEP is feasible, safe, and effective with comparable results with high-power ThuVEP in the treatment of BPO.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Túlio , Humanos , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/patologia , Masculino , Idoso , Túlio/uso terapêutico , Estudos Prospectivos , Lasers de Estado Sólido/uso terapêutico , Terapia a Laser/métodos , Pessoa de Meia-Idade , Tamanho do Órgão , Prostatectomia/métodos , Resultado do Tratamento , Próstata/patologia , Próstata/cirurgia
8.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478094

RESUMO

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Túlio/uso terapêutico , Litotripsia a Laser/métodos , Cálculos Renais/cirurgia
9.
World J Urol ; 42(1): 33, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217743

RESUMO

PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.


Assuntos
Alumínio , Lasers de Estado Sólido , Litotripsia a Laser , Urolitíase , Ítrio , Humanos , Túlio , Urolitíase/cirurgia , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Tecnologia , Hólmio
10.
World J Urol ; 42(1): 431, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39037668

RESUMO

PURPOSE: This study compares the peri-operative and functional outcomes of three distinct surgical techniques in Thulium Laser Enucleation of the Prostate (ThuLEP) for benign prostatic hyperplasia (BPH). The main aim is to assess whether the En-bloc, Three-lobe, and Two-lobe techniques have differential effects on surgical efficacy and patient outcomes. METHODS: A retrospective analysis was conducted on patients undergoing ThuLEP for BPH between January 2019 and January 2024 at two tertiary centers. Propensity score matching was utilized to balance baseline characteristics among patients undergoing the different techniques. Surgical parameters, including operative time, enucleation time, morcellation time, energy consumption, and postoperative outcomes, were compared among the groups. RESULTS: Following propensity score matching, 213 patients were included in the analysis. Intraoperative analysis revealed significantly shorter enucleation, laser enucleation, morcellation and operative times and total energy delivered in the En-bloc and Two-lobe groups compared to the Three-lobe group. No significant differences were observed among the groups in terms of intraoperative and postoperative complications. There were no significant differences in functional outcomes at the 3-month follow-up among the groups. CONCLUSION: The findings of this study suggest that while the En-bloc and Two-lobe techniques may offer efficiency benefits and could be considered safe alternatives in ThuLEP procedures, the reduction in laser enucleation time and energy delivered did not necessarily translate into improvements in post operative storage symptoms or other functional outcomes for the patients. Surgeon preference and proficiency may play a crucial role in selecting the most suitable technique for individual patients. Future research should focus on larger-scale prospective studies to further validate these findings and explore potential factors influencing surgical outcomes.


Assuntos
Pontuação de Propensão , Hiperplasia Prostática , Humanos , Hiperplasia Prostática/cirurgia , Masculino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Túlio/uso terapêutico , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Prostatectomia/métodos , Ressecção Transuretral da Próstata/métodos , Duração da Cirurgia
11.
World J Urol ; 42(1): 246, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643250

RESUMO

PURPOSE: To assess the learning curve of Thulium laser enucleation of the prostate (ThuLEP) of a single surgeon. METHODS: Hundred patients suffering from benign prostatic hyperplasia were treated by the same surgeon. In all cases, a well-trained urologist was present in the operating room. Patients urinary function was assessed preoperatively using the International Prostate Symptoms Score (IPSS), maximum flow rate and Post-Void Residual volume. Preoperative prostate volume was recorded. Enucleation and morcellation efficiency and complication rate were evaluated. Patients were divided into 5 cohorts of 20 consecutive cases to assess changes in outcomes through time. RESULTS: Mean age of patients was 73.1 years (SD 17.5) and mean prostate volume was 89.7 ml (SD 55.1). Overall, mean enucleation and morcellation efficiency were 1.7 (SD 2.9) and 5.1 (SD 2.7) g/min. A statistically significant increase in enucleation efficiency was observed when comparing cohort 1 vs 2 (0.9 vs 1.3 g/min, p = 0.03) and cohort 2 vs 3 (1.3 vs 1.7 g/min, p = 0.02). A statistically significant increase in morcellation efficiency was observed when comparing cohort 1 vs 2 (2.8 vs 3.7 g/min, p = 0.02) and cohort 2 vs 3 (3.7 vs 4.9 g/min, p = 0.03). In both cases, no significant differences were observed when comparing the following cohorts. Complication rate showed no significant differences throughout the caseload. CONCLUSIONS: In our single-surgeon experience, we observed a learning curve of nearly 60 cases for the ThuLEP procedure in presence of a well-trained surgeon. Complication rate was low from the beginning of surgical experience.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Masculino , Humanos , Idoso , Próstata/cirurgia , Túlio , Curva de Aprendizado , Resultado do Tratamento , Terapia a Laser/métodos , Hiperplasia Prostática/cirurgia , Lasers de Estado Sólido/uso terapêutico
12.
World J Urol ; 42(1): 57, 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38280001

RESUMO

INTRODUCTION: Both Holmium:yttrium-aluminium-garnet (Ho:YAG) laser and Thulium Fiber Laser (TFL) can effectively treat all urinary stone types. This in vitro study evaluated the ablation volume per pulse (AVP) and required energy needed to ablate 1mm3 (RE, J/mm3) of various stone types at different laser settings with TFL. METHODS: 272-µm core-diameter laser fibers (Boston Scientific©) were connected to a 50 Watts TFL generator (IPG®). An experimental setup immerged human stones of calcium oxalate monohydrate (COM), uric acid (UA), and cystine (CYS) with a single pulse lasing emission (0.5/0.8/1 J), in contact mode. Stones were dried out before three-dimensional scanning to measure AVP and deduce from the pulse energy (PE) and AVP the RE. A direct comparison with known Ho:YAG's AVP and RE was then carried out. RESULTS: AVP for COM stones was significantly greater than those for CYS stones and similar to UA stones (p = 0.02 and p = 0.06, respectively). If AVP increased with PE against COM and UA stones, AVP decreased against CYS stones. 1 J PE resulted in a threefold lower RE compared with other PE for COM stones. On the contrary, RE for CYS increased with PE, whereas PE did not had influence on RE for UA. TFL was associated with greater AVP for COM, but lower for UA and CYS stones compared to Ho:YAG laser. CONCLUSION: This in vitro study firstly describes the ablation volume per pulse and required energy to treat a cubic millimeter of three frequent human stone types, and suggest TFL could not be suited for cystine. Therefore, stone composition could be considered when choosing the laser source for lithotripsy.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Litotripsia a Laser , Nefrolitíase , Cálculos Urinários , Humanos , Litotripsia a Laser/métodos , Túlio , Cistina , Cálculos Urinários/cirurgia , Lasers de Estado Sólido/uso terapêutico , Hólmio
13.
World J Urol ; 42(1): 49, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38244076

RESUMO

PURPOSE: Holmium laser enucleation of the prostate (HoLEP) represents the current standard procedure for size-independent surgical therapy of benign prostatic obstruction (BPO). With advent of the novel laser technology thulium fiber laser (TFL), we hypothesized that the functional outcome of TFL enucleation of the prostate (ThuFLEP) is non-inferior compared to HoLEP. METHODS: From October 2021 to October 2022, 150 patients with BPO were recruited for the prospective randomized trial in accordance with CONSORT. Stratified randomization into the arms ThuFLEP (n = 74) or HoLEP (n = 76) was carried out. The primary endpoint was non-inferior international prostate symptom score (IPSS) and quality of life (QoL) at three months after treatment. Secondary endpoints were rates of complications, peak flow, residual urine and operation times. RESULTS: Preoperative characteristics showed no significant differences. Overall IPSS and QoL improved from 21 to 8 and 4 to 1.5, respectively, after three months of follow-up. No statistically significant differences between ThuFLEP and HoLEP were observed regarding median postoperative IPSS (8.5 vs. 7, p > 0.9), QoL (1 vs. 2, p = 0.6), residual urine (48 vs. 30ml, p = 0.065) and peak flow (19 vs. 17ml/s, p > 0.9). Similarly, safety profile was comparable with no statistically significant differences regarding rate of major complications (5.3 vs. 5.4%, p = 0.5), laser hemostasis time (3 vs. 2min, p = 0.2), use of additive electric coagulation (74 vs. 87%, p = 0.06) or electric coagulation time (8 vs. 8min, p = 0.4). CONCLUSIONS: In this prospective, randomized trial ThuFLEP showed non-inferior results compared to HoLEP in terms of functional outcomes measured by IPSS and QoL as primary endpoint. TRIAL REGISTRATION NUMBER: DRKS00032699 (18.09.2023, retrospectively registered).


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Retenção Urinária , Masculino , Humanos , Próstata/cirurgia , Lasers de Estado Sólido/uso terapêutico , Túlio/uso terapêutico , Qualidade de Vida , Hiperplasia Prostática/complicações , Estudos Prospectivos , Resultado do Tratamento , Terapia a Laser/métodos , Retenção Urinária/cirurgia , Hólmio
14.
Curr Urol Rep ; 25(4): 71-78, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38349464

RESUMO

PURPOSE OF REVIEW: Lasers have had a significant impact on the treatment of benign prostatic hypertrophy. This article attempts to distill the advancements in laser technology for the treatment of benign prostatic hypertrophy (BPH) into key and understandable points to help make this topic more accessible to urologists. RECENT FINDINGS: The holmium:yttrium-aluminum-garnet (YAG) laser, one of the most significant lasers in the field of urology, has recently been improved with pulse modulating technology (Moses™ technology). New thulium:YAG technology allows both pulsed and continuous wave modes. The thulium fiber laser is one of the newer lasers to come to market and has been shown to have effective and safe outcomes. GreenLight™ lasers are predominantly used in photovaporization procedures and have also been studied extensively, although less in recent years. The modern urologist is fortunate to have many high-quality lasers and a wide variety of surgical techniques to choose from when treating BPH. Understanding the basic laser principles and applications will help urologists to select the best treatment options for their patients with BPH.


Assuntos
Hiperplasia Prostática , Humanos , Masculino , Hiperplasia Prostática/cirurgia , Túlio , Lasers , Tecnologia , Urologistas
15.
Lasers Surg Med ; 56(6): 592-596, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38890781

RESUMO

BACKGROUND: Skin rejuvenation is a widely sought-after goal, prompting advancements in laser technology for noninvasive and effective treatments. Ablative lasers, in particular, have evolved to address diverse skin concerns, with fractional ablative lasers offering better-tolerated outcomes. The introduction of a novel ablative Thulium pulsed laser, based on Thulium-doped Yttrium aluminum Perovskite (Tm:YAP) crystal, delivers precise and controlled skin rejuvenation by allowing customization of ablative microcolumns. METHODS: A pilot in vivo study was conducted on the abdominal skin of a live female pig. Using the Laser Team Medical (LTM) prototype laser, treatments were administered with varying coagulation settings (minimal and maximum) and energies (32, 80, 120, and 160 mJ per microcolumn). Biopsies were harvested, fixed, and stained for subsequent analysis. The penetration depth and width of the microcolumns were evaluated. RESULTS: Low coagulation settings produced ablative microcolumns with thermal affected zones of 160 µm width, while high coagulation settings resulted in wider zones of 400-530 µm. The ablation cavities' width was estimated to be less than 100 µm in both settings. The novel 1940 nm pulsed laser demonstrated superior microcolumn properties, offering potential advantages such as shorter downtime and increased efficacy compared to existing fractional ablative lasers. CONCLUSION: This study presents encouraging preliminary results regarding the efficacy and safety of the first ablative 1940 nm pulsed laser. The results show ablative microcolumns thinner than the counterpart devices, showing the device safety and potential higher efficacy along with short downtime. The LTM novel ablative 1940 nm pulsed laser holds immense potential for enhancing skin rejuvenation treatments due to its superior microcolumns properties. The versatility of this laser can open new treatment procedures and may extend to different areas of dermatology.


Assuntos
Lasers de Estado Sólido , Rejuvenescimento , Animais , Feminino , Suínos , Lasers de Estado Sólido/uso terapêutico , Projetos Piloto , Envelhecimento da Pele/efeitos da radiação , Terapia a Laser/métodos , Terapia a Laser/instrumentação , Pele/efeitos da radiação , Túlio
16.
Lasers Med Sci ; 39(1): 190, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39042320

RESUMO

This meta-analysis evaluates the efficacy and safety of greenlight (PVP) and thulium laser vaporization (ThuVAP) in Benign Prostatic Hyperplasia (BPH) treatment. A systematic literature search was conducted in databases including PubMed, Cochrane Library, EMBASE, CNKI, Wangfang, and VIP in November 2023. Following the PRISMA guidelines, a systematic review and meta-analysis of the primary outcomes of interest were performed. The review was prospectively registered on PROSPERO under the registration number CRD42023491316. A total of 13 studies were included. The results of the meta-analysis showed that compared to PVP, ThuVAP had a shorter operation time (MD: 8.56, 95% CI: 4.10 ~ 13.03, p = 0.0002), and higher postoperative transfusion (OR:0.26, 95% CI: 0.10 ~ 0.64, p = 0.004). However, no significant differences were observed between the two groups in terms of length of stay (MD: -0.32, 95% CI: -0.78 ~ 0.14, p = 0.17), catherization time (MD: 0.03, 95% CI: -0.13 ~ 0.19, p = 0.73), international prostate symptom score improvement (MD: 0.23, 95% CI: -0.36 ~ 0.81, p = 0.45), quality of life improvement (MD: 0.04, 95% CI: -0.04 ~ 0.12, p = 0.29), maximum urinary flow rate improvement (MD: -0.59, 95% CI: -1.42 ~ 0.24, p = 0.16), postvoid residual urine volume improvement (MD: 1.04, 95% CI: -6.63 ~ 8.71, p = 0.79), overall postoperative complications (OR:1.15, 95% CI: 0.65 ~ 2.03, p = 0.63), postoperative bleeding (OR:1.18, 95%  CI: 0.67 ~ 2.07, p = 0.56), re-peration (OR:0.55, 95% CI: 0.16 ~ 1.95, p = 0.35), urethral stricture (OR:0.90, 95% CI: 0.46 ~ 1.75, p = 0.75), and urinary incontinence (OR:1.07, 95% CI: 0.64 ~ 1.78, p = 0.80). The results of subgroup analysis showed that the results of comparing thulium vaporesection or vapoenucleation with PVP were consistent with the results of the pooled analysis. Both greenlight and thulium laser vaporization are effective and safe, with comparable surgical and functional outcomes. The choice between these methods should be based on patient-specific factors.


Assuntos
Terapia a Laser , Hiperplasia Prostática , Túlio , Hiperplasia Prostática/cirurgia , Humanos , Masculino , Terapia a Laser/métodos , Terapia a Laser/efeitos adversos , Resultado do Tratamento , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Qualidade de Vida , Tempo de Internação/estatística & dados numéricos
17.
Lasers Med Sci ; 39(1): 173, 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38969818

RESUMO

OBJECTIVE: To determine the effectiveness of picosecond KTP in reducing peri-ocular dark circles caused mainly by excessive pigmentation and to compare Picosecond KTP with Thulium laser ability in reducing the intensity and extent of peri-ocular dark circles. MATERIALS AND METHODS: This split-face prospective study included twelve women with periorbital dark circles (pigmented or mixed-pigmented type). The left lower eyelid was treated using the PicoHi machine (HIRONIC Ltd), a full beam Q-switched Nd-YAG provided by KTP crystal (523 nm) at settings of 0.3 J/cm2, 5 mm, 5 Hz, and 300 Ps. Whereas the right lower eyelid was treated using the Lavieen machine (WON TECH Co., Ltd), a fractional Thulium laser (1927 nm) at setting 1320 mJ/cm2, 30 × 15 mm, 1500 microseconds. Patients received a series of 3 treatment sessions, given at 4-week intervals. RESULTS: The 532-nm full beam Q-switched KTP and fractional Thulium lasers were more likely to induce post-inflammatory hyperpigmentation rather than decrease the pigmentation. The risk is higher with a Q-switched KTP laser, which may be attributed to the skin tone of the participants. Nonetheless, some improvement in the pigmented type of PDCs, although not detected clinically, was documented by the VISIA software. CONCLUSION: No solid conclusion can be drawn from the results of the study. Picosecond KTP and Thulium lasers may have a role in reducing PDCs yet more studies should be performed in order to determine the exact impact these lasers have.


Assuntos
Hiperpigmentação , Lasers de Estado Sólido , Túlio , Humanos , Feminino , Lasers de Estado Sólido/uso terapêutico , Estudos Prospectivos , Adulto , Pessoa de Meia-Idade , Hiperpigmentação/radioterapia , Terapia com Luz de Baixa Intensidade/métodos , Terapia com Luz de Baixa Intensidade/instrumentação , Resultado do Tratamento
18.
Lasers Med Sci ; 39(1): 185, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39026130

RESUMO

Through an ex vivo experimental study, we aimed to compare the effects of the Ho: YAG laser Virtual Basket (VB™) modulation and a Thulium fiber laser (TFL) on kidney tissue in different environments and using laser configurations. The 100 W Ho: YAG (Cyber Ho, Quanta System, Italy) and 60 W TFL (Fiber Dust, Quanta System, Italy) laser devices were used. The following laser settings were selected: power in the range of 10-60 W, frequency of 20-40 Hz, and energy of 0.5-1-1.5 J. A medium pulse duration of 600 µsec was used for VB™, while short (spdTFL; 50 µsec) and long (lpdTFL; 15,000 µsec) were used for TFL. The tissue's incision depth (ID), vaporization area (VA), coagulation area (CA), total laser area (TLA = VA + CA), surface section (SS), and lateral effect (LE) were measured. In total, 108 experiments were conducted. No statistically significant difference in mean VA, TLA, ID, LE, or SS was observed between VB™, spdTFL, and lpdTFL in the low-power output group in saline (p > 0.05). However, the mean CA was statistically significantly higher for VB™ (p = 0.005). In saline and high-power output group, the mean VA, CA, TLA, LE, and ID were higher when using lpdTFL than other pulse durations (p = 0.001, p = 0.001, p = 0.001, p = 0.006, and p = 0.001, respectively). Similar to lpdTFL, VB™ may provide controlled dissection and incision as well as haemostasis. At different laser settings, the individual effects of laser properties (such as pulse length, energy and frequency) on tissue may be more significant.


Assuntos
Rim , Lasers de Estado Sólido , Túlio , Lasers de Estado Sólido/uso terapêutico , Rim/cirurgia , Rim/efeitos da radiação , Animais , Suínos , Terapia a Laser/métodos , Terapia a Laser/instrumentação
19.
Lasers Med Sci ; 39(1): 126, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38714553

RESUMO

Thulium laser enucleation of the prostate (ThuLEP) is a highly effective approach to the treatment of benign prostatic hyperplasia. We present here a description of the "ARTh Technique" and the benefits it offers in terms of improved visualization, short operation times, and easy recognition of the dissection plane, describing specifically the anterior release (AR) technique using ThuLEP(Th). Included in this retrospective study were 32 consecutive patients operated on between January 2022-November 2022. Parameters were measured before and after the procedure: the International Prostate Symptom Score(IPSS), maximum flow rate(Qmax), post-void residual urine(PVR) prostate-specific antigen(PSA), prostate volume, operation-time, morcellation-time, catheterization-time and presence of transient urinary incontinence, and compared. The median age of patients undergoing enucleation of the prostate using the ARTh technique was 64 years (range: 44-83). The median prostate volume of the patients was 83.5 ml(50-128 ml), preoperative-IPSS was 24.8(15-33), postoperative-IPSS was 7(5-11), preoperative-Qmax was 8.1 ml/Sects. (5-11.5 ml/sec), postoperative-Qmax was 26.9 ml/Sect. (20.8-34 ml/sec), preoperative-PVR was 145 ml(75-258 ml), postoperative-PVR was 36.2 ml(0-66 ml), total operation time was 51.4 min(28-82 min), enucleation time was 36.9 min(19-51 min) and morcellation time was 15.3 min(8-27 min). The ARTh technique is a safe procedure that allows the surgeon to easily recognize and adhere to the defined dissection plane, thus decreasing operation times, significantly reducing the rate of postoperative transient urinary incontinence (TUI).


Assuntos
Lasers de Estado Sólido , Hiperplasia Prostática , Túlio , Humanos , Masculino , Hiperplasia Prostática/cirurgia , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Lasers de Estado Sólido/uso terapêutico , Adulto , Terapia a Laser/métodos , Terapia a Laser/instrumentação , Próstata/cirurgia , Prostatectomia/métodos , Duração da Cirurgia , Resultado do Tratamento
20.
Int Braz J Urol ; 50(3): 309-318, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38446905

RESUMO

BACKGROUND: To evaluate the 10-year functional outcomes (primary) and frequency and predictors of BPH surgical retreatment (secondary) after ThuLEP. MATERIALS AND METHODS: A single-center retrospective analysis of consecutive patients undergoing ThuLEP between 2010 and 2013 was performed. Inclusion criteria were: age ≥ 40 years, prostate volume (PV) ≥ 80 mL, International Prostate Symptom Score (IPSS)-Total score ≥ 8 points. IPSS-Total score was the primary outcome, and BPH surgical retreatment rate was the secondary outcome. Paired t-test, McNemar test, and Wilcoxon signed-rank test were used to compare variables. Logistic regression analysis was performed to evaluate predictors of surgical retreatment. RESULTS: A total of 410 patients with a mean ±SD age of 63.9 ± 9.7 years and a PV of 115.6 ± 28.6 mL were included. Mean ±SD follow-up was 108.2 ± 29.6 months. IPSS-Total score was significantly improved at 1 year compared to baseline (23.3 ± 4.7 vs. 10.3 ± 3.8; p<0.001). It was similar after 5 years (10.5 ± 3.6 vs. 10.7 ± 5.0; p=0.161), with a significant worsening at 10 years (10.3 ±4.8 vs. 13.8 ±4.5; p=0.042) but remaining statistically and clinically better than baseline (13.8 ±4.5 vs. 22.1 ±4.3; p<0.001). After 10 years, 21 (5.9%) patients had undergone BPH reoperation. Baseline PV (adjusted OR 1.27, 95% CI 1.09-1.41; p<0.001) and time from BPH surgery (adjusted OR 1.32, 95% CI 1.15-1.43; p<0.001) were predictors of BPH surgical retreatment. CONCLUSIONS: ThuLEP is associated with optimal functional outcomes and a low frequency of BPH surgical retreatment in the long-term. Baseline PV and time from surgery were predictors of BPH reoperation.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Próstata/cirurgia , Seguimentos , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/complicações , Túlio , Estudos Retrospectivos , Resultado do Tratamento , Lasers de Estado Sólido/uso terapêutico , Retratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA