Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.300
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Childs Nerv Syst ; 40(8): 2391-2399, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38587626

RESUMO

PURPOSE: Telemetric monitoring of intracranial pressure (ICP) facilitates long-term measurements and home monitoring, thus potentially reducing diagnostic imaging and acute hospital admissions in favour of outpatient appointments. Especially in paediatric patients, telemetric ICP monitoring requires a high level of collaboration and compliance from patients and parents. In this study, we aim to systematically investigate (1) patient and parent perception of telemetric ICP system utility and (2) hospital contact history and thus the potential cost-benefit of telemetric ICP monitoring in paediatric patients with a cerebrospinal fluid disorder. METHODS: We conducted a nationwide questionnaire study, including paediatric patients with either a current or previous telemetric ICP sensor and their parents. Additionally, a retrospective review of electronic health records for all included children was performed. RESULTS: We included 16 children (age range 3-16 years), with a total of 41 telemetric ICP sensors implanted. Following sensor implantation, the frequency of telephone contacts and outpatient visits increased. No corresponding decrease in hospital admissions or total length of stay was found. The telemetric ICP sensor provided most parents with an improved sense of security and was seen as a necessary and valuable tool in treatment guidance. The size and shape of the sensor itself were reported as disadvantages, while the external monitoring equipment was reported as easy to use but too large and heavy for a child to carry. CONCLUSION: Though, in quantitative terms, there was no cost-benefit of the telemetric ICP sensor, it contributed to extended parental involvement and a sense of improved safety.


Assuntos
Pressão Intracraniana , Telemetria , Humanos , Criança , Adolescente , Feminino , Masculino , Pré-Escolar , Pressão Intracraniana/fisiologia , Inquéritos e Questionários , Telemetria/métodos , Estudos Retrospectivos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Pais
2.
An Acad Bras Cienc ; 96(suppl 1): e20231019, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39082590

RESUMO

Many aspects of the ecology, evolution and social behavior of wild-living primates remain un-explored and require further investigation. While long-term field studies are crucial for addressing conservation concerns for many primates' species, acquiring the necessary data is often challenging, often due to difficulties in locating study groups. Radio-telemetry has significantly facilitated the study of primates and other animals living in tropical forests. However, there are important practical challenges in the process of capturing and releasing animals after placement of telemetry collars. In this study, we report guidelines and considerations for capturing and collaring wild capuchin monkeys, Sapajus nigritus cucullatus, in the Atlantic Forest of Argentina. Our ultimate goal is to contribute to making captures safer, preventing harm and stress to animals when using radio-telemetry in monitoring strategies for conservation of this primate species. These methods can be useful for researchers using field capture and radio-telemetry for monitoring groups or populations of wild primates, specifically wild Sapajus.


Assuntos
Telemetria , Animais , Telemetria/métodos , Argentina , Sapajus , Conservação dos Recursos Naturais/métodos , Animais Selvagens
3.
Eur Arch Otorhinolaryngol ; 281(7): 3461-3473, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38219245

RESUMO

PURPOSE: The purpose of this retrospective study is to compare the results of electrically evoked compound action potential (ECAP) measurements using automatic auditory response telemetry (AutoART) with those obtained by ART in adults. The study also aimed to evaluate the predictive value of intraoperative ART and AutoART ECAPs for speech intelligibility (SI) and hearing success (HS), and to determine if cochlear nerve (CN) cross-sectional area (CSA) obtained preoperatively by magnetic resonance imaging (MRI) scans could predict ART and AutoART ECAPs and SI and HS outcome. METHODS: The study analyzed and correlated ART and AutoART ECAP thresholds at electrodes E2, E6, and E10, as well as averaged ECAP thresholds over electrodes E1-E12, using data from 32 implants. Correlations were also examined for ART and AutoART ECAP slopes. In addition, averaged ART and AutoART ECAP thresholds and slopes over all 12 electrodes for each participant were correlated with CN CSA measured from MRI sequences. SI of the monosyllabic Freiburg Speech Test at 65 dB sound pressure level was examined along with averaged ART and AutoART thresholds and slopes over all 12 electrodes. A parallel analysis was performed for HS, derived from the difference between baseline and 6-month SI. Finally, correlations between CN CSA and SI, as well as CN CSA and HS were examined. RESULTS: The results of the study showed a significant positive correlation between ART and AutoART ECAP thresholds and as well as slopes for E2, E6, E10 and averaged thresholds and slopes of E1-E12. However, no significant correlation was observed between ART and AutoART averaged ECAP thresholds and slopes and either SI and HS or CN CSA. Furthermore, no significant correlation was found between CN CSA and SI and HS. CONCLUSION: While AutoART is a reliable and safe program for measuring ECAPs in adults, the study found no preoperative prognostic information on intraoperative ECAP results using parameters extracted from current MRI sequences or pre-/intraoperative information on subsequent hearing outcome using ECAP and CN CSA.


Assuntos
Implantes Cocleares , Nervo Coclear , Potenciais Evocados Auditivos , Imageamento por Ressonância Magnética , Humanos , Nervo Coclear/diagnóstico por imagem , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Imageamento por Ressonância Magnética/métodos , Potenciais Evocados Auditivos/fisiologia , Implante Coclear/métodos , Telemetria/métodos , Inteligibilidade da Fala/fisiologia , Adulto Jovem , Valor Preditivo dos Testes , Limiar Auditivo/fisiologia , Potenciais de Ação/fisiologia
4.
Sensors (Basel) ; 24(14)2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-39065825

RESUMO

In this paper, we present the design of a millimeter-wave 1 × 4 linear MIMO array antenna that operates across multiple resonance frequency bands: 26.28-27.36 GHz, 27.94-28.62 GHz, 32.33-33.08 GHz, and 37.59-39.47 GHz, for mm-wave wearable biomedical telemetry application. The antenna is printed on a flexible substrate with dimensions of 11.0 × 44.0 mm2. Each MIMO antenna element features a modified slot-loaded triangular patch, incorporating 'cross'-shaped slots in the ground plane to improve impedance matching. The MIMO antenna demonstrates peak gains of 6.12, 8.06, 5.58, and 8.58 dBi at the four resonance frequencies, along with a total radiation efficiency exceeding 75%. The proposed antenna demonstrates excellent diversity metrics, with an ECC < 0.02, DG > 9.97 dB, and CCL below 0.31 bits/sec/Hz, indicating high performance for mm-wave applications. To verify its properties under flexible conditions, a bending analysis was conducted, showing stable S-parameter results with deformation radii of 40 mm (Rx) and 25 mm (Ry). SAR values for the MIMO antenna are calculated at 28.0/38.0 GHz. The average SAR values for 1 gm/10 gm of tissues at 28.0 GHz are found to be 0.0125/0.0079 W/Kg, whereas, at 38.0 GHz, average SAR values are 0.0189/0.0094 W/Kg, respectively. Additionally, to demonstrate the telemetry range of biomedical applications, a link budget analysis at both 28.0 GHz and 38.0 GHz frequencies indicated strong signal strength of 33.69 dB up to 70 m. The fabricated linear MIMO antenna effectively covers the mm-wave 5G spectrum and is suitable for wearable and biomedical applications due to its flexible characteristics.


Assuntos
Telemetria , Dispositivos Eletrônicos Vestíveis , Telemetria/instrumentação , Telemetria/métodos , Humanos , Tecnologia sem Fio/instrumentação , Desenho de Equipamento
5.
Sensors (Basel) ; 24(12)2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38931520

RESUMO

With the escalation in the size and complexity of modern Denial of Service attacks, there is a need for research in the context of Machine Learning (ML) used in attack execution and defense against such attacks. This paper investigates the potential use of ML in generating behavioral telemetry data using Long Short-Term Memory network and spoofing requests for the analyzed traffic to look legitimate. For this research, a custom testing environment was built that listens for mouse and keyboard events and analyzes them accordingly. While the economic feasibility of this attack currently limits its immediate threat, advancements in technology could make it more cost-effective for attackers in the future. Therefore, proactive development of countermeasures remains essential to mitigate potential risks and stay ahead of evolving attack methods.


Assuntos
Segurança Computacional , Aprendizado de Máquina , Memória de Curto Prazo/fisiologia , Humanos , Telemetria/métodos , Redes de Comunicação de Computadores , Algoritmos
6.
J Med Syst ; 48(1): 72, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39101979

RESUMO

Wireless medical telemetry systems (WMTSs) are typical radio communication-based medical devices that monitor various biological parameters, such as electrocardiograms and respiration rates. In Japan, the assigned frequency band for WMTSs is 400 MHz. However, the issues accounting for poor reception in WMTS constitute major concerns. In this study, we analyzed the effects of electromagnetic interferences (EMIs) caused by other radio communication systems, the intermodulation (IM) effect, and noises generated from electrical devices on WMTS and discussed their management. The 400-MHz frequency band is also shared by other radio communication systems. We showed the instantaneous and impulsive voltages generated from the location-detection system for wandering patients and their potential to exhibit EMI effects on WMTS. Further, we presented the IM effect significantly reduces reception in WMTS. Additionally, the electromagnetic noises generated from electrical devices, such as light-emitting diode lamps and security cameras, can exceed the 400 MHz frequency band as these devices employ the switched-mode power supply and/or central processing unit and radiate wideband emissions. Moreover, we proposed and evaluated simple and facile methods using a simplified spectrum analysis function installed in the WMTS receiver and software-defined radio for evaluating the electromagnetic environment.


Assuntos
Telemetria , Tecnologia sem Fio , Tecnologia sem Fio/instrumentação , Telemetria/instrumentação , Telemetria/métodos , Humanos , Campos Eletromagnéticos , Fenômenos Eletromagnéticos
7.
Mamm Genome ; 34(2): 166-179, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36749381

RESUMO

Genetically or surgically altered mice are commonly used as models of human cardiovascular diseases. Electrocardiography (ECG) is the gold standard to assess cardiac electrophysiology as well as to identify cardiac phenotypes and responses to pharmacological and surgical interventions. A variety of methods are used for mouse ECG acquisition under diverse conditions, making it difficult to compare different results. Non-invasive techniques allow only short-term data acquisition and are prone to stress or anesthesia related changes in cardiac activity. Telemetry offers continuous long-term acquisition of ECG data in conscious freely moving mice in their home cage environment. Additionally, it allows acquiring data 24/7 during different activities, can be combined with different challenges and most telemetry systems collect additional physiological parameters simultaneously. However, telemetry transmitters require surgical implantation, the equipment for data acquisition is relatively expensive and analysis of the vast number of ECG data is challenging and time-consuming. This review highlights the limits of non-invasive methods with respect to telemetry. In particular, primary screening using non-invasive methods can give a first hint; however, subtle cardiac phenotypes might be masked or compensated due to anesthesia and stress during these procedures. In addition, we detail the key differences between the mouse and human ECG. It is crucial to consider these differences when analyzing ECG data in order to properly translate the insights gained from murine models to human conditions.


Assuntos
Doenças Cardiovasculares , Eletrocardiografia , Animais , Camundongos , Humanos , Frequência Cardíaca/fisiologia , Eletrocardiografia/métodos , Telemetria/métodos , Coração
8.
Heart Fail Rev ; 28(1): 249-260, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36001250

RESUMO

Innovations in the development of novel heart failure therapies are essential to further increase the predictive value of early research findings. Animal models are still playing a pivotal role in 'translational research'. In recent years, the transferability from animal studies has been more and more critically discussed due to persistent high attrition rates in clinical trials. However, there is an increasing trend to implement mobile health devices in preclinical studies. These devices can increase the predictive value of animal models by providing more accurate and translatable data and protect from confounding factors. This review outlines the current prevalence and opportunities of these techniques in preclinical heart failure research studies to accelerate the integration of these important tools. A literature screening for preclinical heart failure studies in large animals implementing telemetry devices over the last decade was performed. Twelve out of 43 publications were included. A variety of different hemodynamic and cardiac parameters can be recorded in conscious state by means of telemetry devices in both, the animal model and the patient. The measurement quality is consistently rated as valid and robust. Mobile health technologies functioning as digital biomarkers represent a more predictive approach compared to the traditionally used invasive measurement techniques, due to the possibility of continuous data collection in the conscious animal. Furthermore, they help to implement the 3R concept (reduction, refinement, replacement) in animal research. Despite this, the use of these techniques in preclinical research has been restrained to date.


Assuntos
Insuficiência Cardíaca , Animais , Humanos , Insuficiência Cardíaca/diagnóstico , Coração , Modelos Animais , Telemetria/métodos , Biomarcadores
9.
Acta Neurochir (Wien) ; 165(6): 1523-1531, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37071182

RESUMO

BACKGROUND: The M.scio telesensor (Aesculap-Miethke, Germany) is a device integrated within a ventriculoperitoneal (VP) shunt for non-invasive measurement of the intracranial pressure (ICP). The purpose of this study was to analyze the telemetric recordings with the M.scio system in shunted patients with idiopathic intracranial hypertension (IIH), in order to determine reference values and assist the interpretation of telemetric data. METHODS: This was a cohort study of consecutive patients with fulminant IIH who underwent primary VP shunt insertion between July 2019 and June 2022. The first telemetric measurements after surgery in the sitting and supine positions were analyzed. Telemetric ICP values, wave morphology, and pulse amplitude were determined for functioning and malfunctioning shunts. RESULTS: Fifty-seven out of 64 patients had available telemetric recordings. The mean ICP was - 3.8 mmHg (standard deviation (SD) = 5.9) in the sitting and 16.4 mmHg (SD = 6.3) in the supine position. The ICP curve demonstrated pulsatility in 49 (86%) patients. A pulsatile curve with mean ICP in the above ranges indicated a functioning shunt, whereas the lack of pulsatility was challenging to interpret. There was a significant positive correlation between ICP versus amplitude, ICP versus body mass index (BMI), and amplitude versus BMI. CONCLUSIONS: This clinical study defined ICP values and curves in IIH patients with a shunt. The results will assist the interpretation of telemetric ICP recordings in clinical decision making. More research is required to model longitudinal recordings and explore the link between telemetric measurements with clinical outcomes.


Assuntos
Pseudotumor Cerebral , Humanos , Pseudotumor Cerebral/diagnóstico , Pseudotumor Cerebral/cirurgia , Pressão Intracraniana , Estudos de Coortes , Derivação Ventriculoperitoneal/métodos , Telemetria/métodos
10.
J Med Internet Res ; 25: e43038, 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37851505

RESUMO

BACKGROUND: Chronic heart failure (HF) is a chronic disease affecting more than 64 million people worldwide, with an increasing prevalence and a high burden on individual patients and society. Telemonitoring may be able to mitigate some of this burden by increasing self-management and preventing use of the health care system. However, it is unknown to what degree telemonitoring has been adopted by hospitals and if the use of telemonitoring is associated with certain patient characteristics. Insight into the dissemination of this technology among hospitals and patients may inform strategies for further adoption. OBJECTIVE: We aimed to explore the use of telemonitoring among hospitals in the Netherlands and to identify patient characteristics associated with the use of telemonitoring for HF. METHODS: We performed a retrospective cohort study based on routinely collected health care claim data in the Netherlands. Descriptive analyses were used to gain insight in the adoption of telemonitoring for HF among hospitals in 2019. We used logistic multiple regression analyses to explore the associations between patient characteristics and telemonitoring use. RESULTS: Less than half (31/84, 37%) of all included hospitals had claims for telemonitoring, and 20% (17/84) of hospitals had more than 10 patients with telemonitoring claims. Within these 17 hospitals, a total of 7040 patients were treated for HF in 2019, of whom 5.8% (409/7040) incurred a telemonitoring claim. Odds ratios (ORs) for using telemonitoring were higher for male patients (adjusted OR 1.90, 95% CI 1.50-2.41) and patients with previous hospital treatment for HF (adjusted OR 1.76, 95% CI 1.39-2.24). ORs were lower for higher age categories and were lowest for the highest age category, that is, patients older than 80 years (OR 0.30, 95% CI 0.21-0.44) compared to the reference age category (18-59 years). Socioeconomic status, degree of multimorbidity, and excessive polypharmacy were not associated with the use of telemonitoring. CONCLUSIONS: The use of reimbursed telemonitoring for HF was limited up to 2019, and our results suggest that large variation exists among hospitals. A lack of adoption is therefore not only due to a lack of diffusion among hospitals but also due to a lack of scaling up within hospitals that already deploy telemonitoring. Future studies should therefore focus on both kinds of adoption and how to facilitate these processes. Older patients, female patients, and patients with no previous hospital treatment for HF were less likely to use telemonitoring for HF. This shows that some patient groups are not served as much by telemonitoring as other patient groups. The underlying mechanism of the reported associations should be identified in order to gain a deeper understanding of telemonitoring use among different patient groups.


Assuntos
Insuficiência Cardíaca , Telemedicina , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Telemetria/métodos , Estudos Retrospectivos , Doença Crônica , Insuficiência Cardíaca/terapia , Projetos de Pesquisa
11.
Sensors (Basel) ; 23(11)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37299963

RESUMO

We introduce a novel ultra-low power system for tracking animal movements over long periods with an unprecedented high-temporal-resolution. The localization principle is based on the detection of cellular base stations using a miniaturized software-defined radio, weighing 2.0 g, including the battery, and having a size equivalent to two stacked 1-euro cent coins. Therefore, the system is small and lightweight enough to be deployed on small, wide-ranging, or migrating animals, such as European bats, for movement analysis with an unprecedented spatiotemporal resolution. The position estimation relies on a post-processing probabilistic RF pattern-matching method based on the acquired base stations and power levels. In several field tests, the system has been successfully verified, and a run-time of close to one year has been demonstrated.


Assuntos
Animais Selvagens , Telemetria , Animais , Telemetria/métodos , Software , Fontes de Energia Elétrica
12.
Bratisl Lek Listy ; 124(10): 783-792, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37789797

RESUMO

It has been exactly 180 years since the pioneering work of Dr. Carlo Matteucci, professor of physics at the University of Pisa (1842), laid the basis of the method for the registration of biopotentials generated by muscles. In particular, these studies have found practical application in the principal non-invasive method of functional diagnosis of the cardiac muscle - electrocardiography (ECG). Almost a century has passed since this method became recognized and widely used in the clinic. However, to date, it has not only retained its importance in practical medicine but also remains a valuable diagnostic tool. This method allows understanding and effectively prevents errors in the present and future repetition. There are observed favorable trends of ECG-based diagnostics systems implementation and improvement in functional assessment of myocardium electrophysiological characteristics, which reflect cardiovascular pathological vital markers. The essential aim of this article is to demonstrate modern approaches of implementing ECG technology to various fields of medicine and health informatics. This research demonstrated a large number of modern innovations devoted to the automation and modification of implementation of this electrophysiological method and the possible ways to implement it in matters of home and individual monitoring of patients. Furthermore, the review examines the socio-economic issues of deploying and administering tele-ECG technologies to follow up on the global principles of digitization of healthcare and on-site diagnostics by emergency medical services (Tab. 2, Fig. 4, Ref. 87). Keywords: electrocardiography, tele-ECG, user bioauthentification.


Assuntos
Serviços Médicos de Emergência , Telemetria , Humanos , Telemetria/métodos , Eletrocardiografia/métodos , Serviços Médicos de Emergência/métodos
13.
Sleep Breath ; 26(1): 125-132, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33846930

RESUMO

PURPOSE: Telemonitoring (TMg) for patients treated with continuous positive airway pressure (CPAP) is now routine care in some sleep labs. The purpose of the present study was to identify technical interventions associated with improved CPAP compliance in a real-life cohort of newly telemonitored patients with obstructive sleep apnea (OSA) during the first 6 months of treatment. METHODS: All patients with moderate-to-severe OSA (apnea-hypopnea index (AHI) ≥ 15/h) who were newly treated with CPAP were included in the study and telemonitored. A group educational session was scheduled after 1 month. Technical interventions were performed at the patient's request and during scheduled visits and the impact of each intervention on CPAP therapy compliance was collected. RESULTS: Between May 2018 and Dec 2019, 349 patients newly diagnosed with OSA were hospitalized in the sleep lab for CPAP titration and 212 patients were included (mean age 54.6 ± 13.1 years, mean BMI 31.7 ± 5.8 kg/m2, mean AHI 42.8 ± 22.0). TMg acceptance rate was 87%. Mean 6-month compliance was 275 ± 154 min, 13% stopped CPAP, and 17% were non-compliant. Correlations were observed between BMI (r = 0.15, p = 0.029), median and 95th percentile leaks (r = -0.23 and -0.18, p = 0.016 and 0.002), and CPAP compliance. During follow-up, 92 interventions were required, mainly for mask change (n = 80). Pressure modification (n = 16) was the only intervention that increased CPAP use > 30 min/night, p = 0.021. CONCLUSION: Pressure modification was the only adaptation that significantly increased CPAP compliance during the first 6 months. Remote TMg allows providing daily, accurate, and immediate feedback that could help clinicians to confirm that the CPAP treatment is effective.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Telemetria/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Cooperação do Paciente , Resultado do Tratamento
14.
Sensors (Basel) ; 22(21)2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-36365905

RESUMO

Recent acoustic telemetry positioning systems are able to reconstruct the positions and trajectories of organisms at a scale of a few centimeters to a few meters. However, they present several logistical constraints including receiver maintenance, calibration procedures and limited access to real-time data. We present here a novel, easy-to-deploy, energy self-sufficient underwater positioning system based on the time difference of arrival (TDOA) algorithm and the Global System for Mobile (GSM) communication technology, capable of locating tagged marine organisms in real time. We provide an illustration of the application of this system with empirical examples using continuous and coded tags in fish and benthic invertebrates. In situ experimental tests of the operational system demonstrated similar performances to currently available acoustic positioning systems, with a global positioning error of 7.13 ± 5.80 m (mean ± SD) and one-third of the pings can be localized within 278 m of the farthest buoy. Despite some required improvements, this prototype is designed to be autonomous and can be deployed from the surface in various environments (rivers, lakes, and oceans). It was proven to be useful to monitor a wide variety of species (benthic and pelagic) in real time. Its real-time property can be used to rapidly detect system failure, optimize deployment design, or for ecological or conservation applications.


Assuntos
Acústica , Rios , Animais , Telemetria/métodos , Organismos Aquáticos , Algoritmos
15.
Sensors (Basel) ; 22(9)2022 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-35591213

RESUMO

Passive human sensing approaches based on the analysis of the radio signals emitted by the most common wireless communication technologies have been steadily gaining momentum during the last decade. In this context, the Bluetooth technology, despite its widespread adoption in mobile and IoT applications, so far has not received all the attention it deserves. However, the introduction of the Bluetooth direction finding feature and the application of Artificial Intelligence techniques to the processing and analysis of the wireless signal for passive human sensing pave the way for novel Bluetooth-based passive human sensing applications, which will leverage Bluetooth Low Energy features, such as low power consumption, noise resilience, wide diffusion, and relatively low deployment cost. This paper provides a reasoned analysis of the data preprocessing and classification techniques proposed in the literature on Bluetooth-based remote passive human sensing, which is supported by a comparison of the reported accuracy results. Building on such results, the paper also identifies and discusses the multiple factors and operating conditions that explain the different accuracy values achieved by the considered techniques, and it draws the main research directions for the near future.


Assuntos
Inteligência Artificial , Tecnologia sem Fio , Humanos , Telemetria/métodos
16.
Sensors (Basel) ; 22(8)2022 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-35458887

RESUMO

Significant progress has been made in the field of micro/nano-retinal implant technologies. However, the high pixel range, power leakage, reliability, and lifespan of retinal implants are still questionable. Active implantable devices are safe, cost-effective, and reliable. Although a device that can meet basic safety requirements set by the Food and Drug Administration and the European Union is reliable for long-term use and provides control on current and voltage parameters, it will be expensive and cannot be commercially successful. This study proposes an economical, fully controllable, and configurable wireless communication system based on field-programmable gated arrays (FPGAs) that were designed with the ability to cope with the issues that arise in retinal implantation. This system incorporates hexagonal biphasic stimulation pulses generated by a digital controller that can be fully controlled using an external transmitter. The integration of two separate domain analog systems and a digital controller based on FPGAs is proposed in this study. The system was also implemented on a microchip and verified using in vitro results.


Assuntos
Próteses e Implantes , Retina , Desenho de Equipamento , Reprodutibilidade dos Testes , Telemetria/métodos , Tecnologia sem Fio
17.
J Fish Biol ; 101(3): 419-430, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34997931

RESUMO

External attachment of electronic tags has been increasingly used in fish studies. Many researchers have used ad hoc attachment methods and provided little or no validation for the assumption that tagging itself does not bias animal behaviour or survival. The authors compared six previously published methods for externally attaching acoustic transmitters to fish in a tank holding experiment with black sea bass Centropristis striata (L.). They tracked tag retention, fish growth and external trauma (as a measure of fish welfare) for 60 days. For each of these metrics, the results showed a wide range of responses among tagging treatments. A simple attachment method using a spaghetti tag passed through the dorsal musculature of the fish and tied to the end cap of the transmitter emerged as the preferred option based on high retention, no impact on growth and relatively low detriment to fish welfare. Future field studies using external electronic tagging should consider tag-related effects that could compromise results when selecting a method for tag attachment.


Assuntos
Bass , Telemetria , Acústica , Animais , Comportamento Animal , Eletrônica , Telemetria/métodos
18.
Ter Arkh ; 94(9): 1062-1066, 2022 Oct 24.
Artigo em Russo | MEDLINE | ID: mdl-36286756

RESUMO

AIM: To evaluate the effectiveness of a new system for telemetric electrocardiogram (ECG) monitoring in patients after endovascular interventions (EI) on the coronary arteries (CA). MATERIALS AND METHODS: 168 patients with chronic ischemic heart disease who underwent EI on the CA on an outpatient basis, and during routine hospitalization, followed by telemetric ECG-monitoring after interventions were included. The monitoring was carried out using a three-channel telemetric recorder Astrocard HE3 (Russia), which provides continuous monitoring of 3-lead ECG for a long time. RESULTS: The telemetry was successfully performed in all 168 (100%) patients. In 165 (98%) patients, the quality of the recording was regarded as good, in 3 (2%) as satisfactory. There were no cases of disconnection of the device, no interruptions in recording. During the observation period, no life-threatening arrhythmia revealed. When comparing the telemetry results in different groups of patients, there were no significant differences in the incidence of arrhythmia. Patients with a history of percutaneous coronary interventions were questioned; according to which 92% of respondents reported that they felt more comfortable after the intervention followed by telemetric ECG-monitoring. CONCLUSION: Carrying out telemetric ECG-monitoring after EI on the CA improves the quality of observation after the procedure, promotes early discharge of patients, makes the intervention more comfortable and safe. The introduction of this technique into clinical practice will make it possible to more widely use the outpatient approach when carrying out EI, and to increase the turnover of specialized beds and the efficiency of the work of medical institutions.


Assuntos
Vasos Coronários , Eletrocardiografia , Humanos , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia/métodos , Telemetria/métodos , Arritmias Cardíacas , Federação Russa
19.
Neurobiol Dis ; 156: 105410, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34087381

RESUMO

We have recently demonstrated the role of the Fyn-PKCδ signaling pathway in status epilepticus (SE)-induced neuroinflammation and epileptogenesis in experimental models of temporal lobe epilepsy (TLE). In this study, we show a significant disease-modifying effect and the mechanisms of a Fyn/Src tyrosine kinase inhibitor, saracatinib (SAR, also known as AZD0530), in the rat kainate (KA) model of TLE. SAR treatment for a week, starting the first dose (25 mg/kg, oral) 4 h after the onset of SE, significantly reduced spontaneously recurring seizures and epileptiform spikes during the four months of continuous video-EEG monitoring. Immunohistochemistry of brain sections and Western blot analyses of hippocampal lysates at 8-day (8d) and 4-month post-SE revealed a significant reduction of SE-induced astrogliosis, microgliosis, neurodegeneration, phosphorylated Fyn/Src-419 and PKCδ-tyr311, in SAR-treated group when compared with the vehicle control. We also found the suppression of nitroxidative stress markers such as iNOS, 3-NT, 4-HNE, and gp91phox in the hippocampus, and nitrite and ROS levels in the serum of the SAR-treated group at 8d post-SE. The qRT-PCR (hippocampus) and ELISA (serum) revealed a significant reduction of key proinflammatory cytokines TNFα and IL-1ß mRNA in the hippocampus and their protein levels in serum, in addition to IL-6 and IL-12, in the SAR-treated group at 8d in contrast to the vehicle-treated group. These findings suggest that SAR targets some of the key biomarkers of epileptogenesis and modulates neuroinflammatory and nitroxidative pathways that mediate the development of epilepsy. Therefore, SAR can be developed as a potential disease-modifying agent to prevent the development and progression of TLE.


Assuntos
Benzodioxóis/uso terapêutico , Modelos Animais de Doenças , Inibidores Enzimáticos/uso terapêutico , Epilepsia do Lobo Temporal/tratamento farmacológico , Ácido Caínico/toxicidade , Proteínas Proto-Oncogênicas c-fyn/antagonistas & inibidores , Quinazolinas/uso terapêutico , Animais , Benzodioxóis/farmacologia , Eletroencefalografia/métodos , Inibidores Enzimáticos/farmacologia , Epilepsia do Lobo Temporal/induzido quimicamente , Epilepsia do Lobo Temporal/metabolismo , Mediadores da Inflamação/antagonistas & inibidores , Mediadores da Inflamação/metabolismo , Masculino , Proteínas Proto-Oncogênicas c-fyn/metabolismo , Quinazolinas/farmacologia , Ratos , Ratos Sprague-Dawley , Espécies Reativas de Oxigênio/antagonistas & inibidores , Espécies Reativas de Oxigênio/metabolismo , Telemetria/métodos
20.
BMC Endocr Disord ; 21(1): 222, 2021 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-34758807

RESUMO

BACKGROUND: Self-monitoring of blood glucose (SMBG) has been shown to reduce hemoglobin A1C (HbA1C). Accordingly, guidelines recommend SMBG up to 4-10 times daily for adults with type 2 diabetes (T2DM) on insulin. For persons not on insulin, recommendations are equivocal. Newer technology-enabled blood glucose monitoring (BGM) devices can facilitate remote monitoring of glycemic data. New evidence generated by remote BGM may help to guide best practices for frequency and timing of finger-stick blood glucose (FSBG) monitoring in uncontrolled T2DM patients managed in primary care settings. This study aims to evaluate the impact of SMBG utility and frequency on glycemic outcomes using a novel BGM system which auto-transfers near real-time FSBG data to a cloud-based dashboard using cellular networks. METHODS: Secondary analysis of the intervention arm of a comparative non-randomized trial with propensity-matched chart controls. Adults with T2DM and HbA1C > 9% receiving care in five primary care practices in a healthcare system participated in a 3-month diabetes boot camp (DBC) using telemedicine and a novel BGM to support comprehensive diabetes care management. The primary independent variable was frequency of FSBG. Secondary outcomes included frequency of FSBG by insulin status, distribution of FSBG checks by time of day, and hypoglycemia rates. RESULTS: 48,111 FSBGs were transmitted by 359 DBC completers. Participants performed 1.5 FSBG checks/day; with 1.6 checks/day for those on basal/bolus insulin. Higher FSBG frequency was associated with greater improvement in HbA1C independent of insulin treatment status (p = 0.0003). FSBG frequency was higher in patients treated with insulin (p = 0.003). FSBG checks were most common pre-breakfast and post-dinner. Hypoglycemia was rare (1.2% < 70 mg/dL). CONCLUSIONS: Adults with uncontrolled T2DM achieved significant HbA1C improvement performing just 1.5 FSBGs daily during a technology-enabled diabetes care intervention. Among the 40% taking insulin, this improvement was achieved with a lower FSBG frequency than guidelines recommend. For those not on insulin, despite a lower frequency of FSBG, they achieved a greater reduction in A1C compared to patients on insulin. Low frequency FSBG monitoring pre-breakfast and post-dinner can potentially support optimization of glycemic control regardless of insulin status in the primary care setting. TRIAL REGISTRATION: Trial registration number: NCT02925312 (10/19/2016).


Assuntos
Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 2/terapia , Atenção Primária à Saúde , Telemetria/métodos , Idoso , Glicemia , Diabetes Mellitus Tipo 2/metabolismo , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemia/metabolismo , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados não Aleatórios como Assunto , Telemedicina , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA