A biogas meter with adjustable resolution and minimal back-pressure.
Smith, Simon A; Stöckle, Claudio O.
Affiliation
  • Smith SA; Department of Biological Systems Engineering, Washington State University, Pullman, WA 99164-6120, USA. simon_smith@wsu.edu
Bioresour Technol ; 99(17): 8537-9, 2008 Nov.
Article in En | MEDLINE | ID: mdl-18424041
ABSTRACT
A new biogas meter was developed to satisfy the need for an adjustable resolution meter that has minimal back-pressure and wide flow rate capability. The new meter had three main components; a timed bellows pump that delivered fixed volumes, a pressure sensor, and a data logger. The meter was built from off-the-shelf components and was thus easy to build and cost effective. The meter also proved to be accurate, precise, sensitive, and simple to calibrate.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bioelectric Energy Sources / Biotechnology Language: En Journal: Bioresour Technol Journal subject: ENGENHARIA BIOMEDICA Year: 2008 Type: Article Affiliation country: United States