Nipro extra-corporeal left ventricular assist device fitting after left ventricular reconstruction with mitral valve plasty.
Arakawa, Mamoru; Yamaguchi, Atsushi; Nishimura, Takashi; Itoh, Satoshi; Yuri, Koichi; Kyo, Shunei; Adachi, Hideo.
Affiliation
  • Arakawa M; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan. a_mamoru@mbn.nifty.com.
  • Yamaguchi A; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan. yamaatsu@omiya.jichi.ac.jp.
  • Nishimura T; Department of Cardiac Surgery, Tokyo Metropolitan Geriatric Hospital, Tokyo, Japan.
  • Itoh S; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan.
  • Yuri K; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan.
  • Kyo S; Department of Cardiac Surgery, Tokyo Metropolitan Geriatric Hospital, Tokyo, Japan.
  • Adachi H; Department of Cardiovascular Surgery, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan.
J Artif Organs ; 18(4): 361-4, 2015 Dec.
Article in En | MEDLINE | ID: mdl-25971993
ABSTRACT
Both left ventricular assist device and left ventricular reconstruction are treatment choices for severe heart failure conditions. Our institution performed a left ventricular assist device installation following a left ventricular reconstruction procedure on a 42-year-old male patient who presented with dilated cardiomyopathy and low cardiac output syndrome. A mitral valve plasty was used to correct the acute mitral valve regurgitation and we performed a Nipro extra-corporeal left ventricular assist device installation on post-operative day 14. Due to the left ventricular reconstruction that the patient had in a previous operation, we needed to attach an apical cuff on posterior apex, insert the inflow cannula with a large curve, and shift the skin insertion site laterally to the left. We assessed the angle between the cardiac longitudinal axis and the inflow cannula using computed tomography. The patient did not complain of any subjective symptoms of heart failure. Although Nipro extra-corporeal left ventricular assist device installation after left ventricular reconstruction has several difficulties historically, we have experienced a successful case.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cardiomyopathy, Dilated / Heart-Assist Devices / Heart Failure / Mitral Valve Insufficiency Limits: Humans / Male / Middle aged Language: En Journal: J Artif Organs Journal subject: ENGENHARIA BIOMEDICA Year: 2015 Type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cardiomyopathy, Dilated / Heart-Assist Devices / Heart Failure / Mitral Valve Insufficiency Limits: Humans / Male / Middle aged Language: En Journal: J Artif Organs Journal subject: ENGENHARIA BIOMEDICA Year: 2015 Type: Article Affiliation country: Japan