Your browser doesn't support javascript.
loading
The lung impedance monitoring in treatment of chronic heart failure (the LIMIT-CHF study).
Domenichini, Giulia; Rahneva, Tsveta; Diab, Ihab G; Dhillon, Onkar S; Campbell, Niall G; Finlay, Malcolm C; Baker, Victoria; Hunter, Ross J; Earley, Mark J; Schilling, Richard J.
Affiliation
  • Domenichini G; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Rahneva T; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Diab IG; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Dhillon OS; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Campbell NG; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Finlay MC; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Baker V; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Hunter RJ; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Earley MJ; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK.
  • Schilling RJ; Department of Arrhythmia Services, Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, EC1A 7BE, UK r.schilling@qmul.ac.uk.
Europace ; 18(3): 428-35, 2016 Mar.
Article in En | MEDLINE | ID: mdl-26683599
ABSTRACT

AIMS:

To assess the usefulness of intrathoracic impedance monitoring (IIM) alerts in guiding empirical treatment of chronic heart failure (CHF) patients to prevent heart failure (HF) hospitalizations and unplanned HF care. METHODS AND

RESULTS:

Chronic heart failure patients with OptiVol or CorVue capable implantable cardioverter-defibrillators were randomized to either the active group (IIM alarm turned on and diuretic dose increased by 50% for 1 week in the event of alarm sounding) or the control group (IIM alarm turned off). The primary endpoint was the number of HF hospitalizations per patient at 1 year. The NYHA class, 6MWT, B-type natriuretic peptide (BNP), and MLWHF questionnaire score were collected at baseline and follow-up. Eighty patients were included and 71 reached 1-year follow-up. There were 1.7 ± 1.5 alerts in the active group and 1.1 ± 1.0 in the control group, P = 0.07. In the active group, 61% of alerts led to a diuretic dose increase. There was a total of 11 HF hospitalizations in the active group vs. 6 in the control group without significant differences in the number of episodes per patient (0.3 ± 0.9 vs. 0.2 ± 0.4, P = 0.95). There were no unplanned HF visits in the active group vs. 0.1 ± 0.3 per patient in the control group, P = 0.08. The total MLWHF scores were significantly increased at the final follow-up in the control group, whereas a trend towards reduction was observed in the active group.

CONCLUSION:

In this study, an empirical HF treatment guided by IIM alerts did not reduce emergency treatment of HF. However, it seems to have a positive impact on quality of life. CLINICAL TRIAL REGISTRATIONURL http//www.clinicaltrials.gov. Unique identifier NCT01320007.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Electric Countershock / Cardiography, Impedance / Defibrillators, Implantable / Heart Failure / Lung Type of study: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Country/Region as subject: Europa Language: En Journal: Europace Journal subject: CARDIOLOGIA / FISIOLOGIA Year: 2016 Type: Article Affiliation country: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Electric Countershock / Cardiography, Impedance / Defibrillators, Implantable / Heart Failure / Lung Type of study: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limits: Aged / Aged80 / Female / Humans / Male / Middle aged Country/Region as subject: Europa Language: En Journal: Europace Journal subject: CARDIOLOGIA / FISIOLOGIA Year: 2016 Type: Article Affiliation country: United kingdom