Your browser doesn't support javascript.
loading
The Impact of Vein Mechanical Compliance on Arteriovenous Fistula Outcomes.
Smith, George E; Barnes, Rachel; Fagan, Michael; Chetter, Ian C.
Affiliation
  • Smith GE; Academic Vascular Surgical Unit, Hull & East Yorkshire NHS Trust/Hull York Medical School, Hull, UK.
  • Barnes R; Academic Vascular Surgical Unit, Hull & East Yorkshire NHS Trust/Hull York Medical School, Hull, UK. Electronic address: Rachel.Barnes@hey.nhs.uk.
  • Fagan M; Medical and Biological Engineering Department, School of Engineering, University of Hull, Hull, UK.
  • Chetter IC; Academic Vascular Surgical Unit, Hull & East Yorkshire NHS Trust/Hull York Medical School, Hull, UK.
Ann Vasc Surg ; 32: 9-14, 2016 Apr.
Article in En | MEDLINE | ID: mdl-26820359
ABSTRACT

BACKGROUND:

Arteriovenous fistulae (AVFs) are the preferred access for hemodialysis but suffer a high early failure rate. The aim of this study was to determine how venous distensibility, as measured in vitro, relates to early outcomes of AVF formed with the sampled vein.

METHODS:

Ethical approval was obtained for all aspects of this study. During AVF formation a circumferential segment of the target vein was sampled. Mechanical stress testing of the venous segments was undertaken using a dynamic mechanical analyzer, with progressive stress loading at 2 N/min to a maximum of 10 N or until sample disruption. Stress-strain curves were obtained for vein samples and Young's modulus (YM) calculated. Duplex assessment of the fistulae was undertaken at 30 days.

RESULTS:

Thirty patients consented to participate with 29 samples obtained for analysis. Statistical comparison of YM demonstrated no relationship with common cardiovascular risk factors or dialysis status. Subject age greater than 65 was the only patient factor which showed a significant difference in YM (P = 0.05). Furthermore, a negative correlation was confirmed between age and YM (Pearson's r = -0.465, P < 0.05). Nine of the 29 subjects suffered an early AVF failure. Mann-Whitney U testing for differences in distribution reported that YM was significantly higher in those fistulas which failed (P < 0.005).

CONCLUSIONS:

Reduced venous compliance appears to result in higher failure rates of AVFs. With the advancement of clinical tools such as speckle tracing ultrasound identification of vessel compliance in vivo may produce valuable additional information for clinicians planning AVF surgery.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Veins / Arteriovenous Shunt, Surgical / Renal Dialysis / Upper Extremity Type of study: Etiology_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Ann Vasc Surg Journal subject: ANGIOLOGIA Year: 2016 Type: Article Affiliation country: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Veins / Arteriovenous Shunt, Surgical / Renal Dialysis / Upper Extremity Type of study: Etiology_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Ann Vasc Surg Journal subject: ANGIOLOGIA Year: 2016 Type: Article Affiliation country: United kingdom