Your browser doesn't support javascript.
loading
Effect of socket-shield technique on alveolar ridge soft and hard tissue in dogs.
Zhang, Zhengchuan; Dong, Yu; Yang, Jiamin; Xu, Ruogu; Deng, Feilong.
Affiliation
  • Zhang Z; Department of Oral Implantology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
  • Dong Y; Department of Oral Implantology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
  • Yang J; Department of Oral Implantology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
  • Xu R; Department of Oral Implantology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
  • Deng F; Department of Oral Implantology, Guangdong Provincial Key Laboratory of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
J Clin Periodontol ; 46(2): 256-263, 2019 02.
Article in En | MEDLINE | ID: mdl-30661247
ABSTRACT

AIM:

To study the soft and hard tissue alterations of the alveolar ridge after socket-shield technique. MATERIALS AND

METHODS:

In four Beagle dogs, the following treatments (Tx) were randomly assigned to 32 extraction sockets Tx1 blood clot; Tx2 Bio-Oss Collagen; Tx3 socket-shield technique and blood clot; Tx4 socket-shield technique and Bio-Oss Collagen. The width and height alterations of the buccal bone plate were calculated by CBCT scans. The dimensional alterations of the buccal aspect of the alveolar ridge at different time points were calculated by impressions using digital imaging analysis. The dogs were sacrificed for micro-CT and histologic analysis 3 months after surgery.

RESULTS:

Width, height and dimensional alterations of Tx3 and Tx4 were significantly lower than those of Tx1 and Tx2. Bone morphological parameters displayed no significant differences among four groups except for the trabecular thickness of Tx1 and Tx2. The quantity and quality of hard tissue containing the residual teeth of Tx3 and Tx4 were much greater than those of Tx1 and Tx2.

CONCLUSIONS:

Socket-shield technique may be beneficial in preserving the soft and hard tissue of the alveolar ridge, which is better than simple bone grafting in the extraction socket.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Alveolar Bone Loss / Alveolar Ridge Augmentation Limits: Animals Language: En Journal: J Clin Periodontol Year: 2019 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Alveolar Bone Loss / Alveolar Ridge Augmentation Limits: Animals Language: En Journal: J Clin Periodontol Year: 2019 Type: Article Affiliation country: China