An Improved Isotope Labelling Method for Quantifying Deamidated Cobratide Using High-Resolution Quadrupole-Orbitrap Mass Spectrometry.
Liu, Bo; Huang, Lu; Xu, Rongrong; Fan, Huihong; Wang, Yue.
Affiliation
  • Liu B; National Institutes for Food and Drug Control, 31st Huatuo Rd., Daxing Dist., Beijing 102629, China.
  • Huang L; NMPA Key Laboratory for Quality Research and Evaluation of Chemical Drugs, Beijing 102629, China.
  • Xu R; National Institutes for Food and Drug Control, 31st Huatuo Rd., Daxing Dist., Beijing 102629, China.
  • Fan H; NMPA Key Laboratory for Quality Research and Evaluation of Chemical Drugs, Beijing 102629, China.
  • Wang Y; National Institutes for Food and Drug Control, 31st Huatuo Rd., Daxing Dist., Beijing 102629, China.
Molecules ; 27(19)2022 Sep 20.
Article in En | MEDLINE | ID: mdl-36234709
ABSTRACT
Protein deamidation can severely alter the physicochemical characteristics and biological functions of protein therapeutics. Cobratide is a non-addictive analgesic with wide clinical acceptance. However, the Asn residue at position 48 from the N-terminus of the cobratide amino acid sequence (N48) tends to degrade during purification, storage, and transport. This characteristic could severely affect the drug safety and clinical efficacy of cobratide. Traditional methods for quantitating deamidation reported in previous research are characterised by low efficiency and accuracy; the quality control of cobratide via this method is limited. Herein, we developed an improved 18O-labelling method based on the detection of a unique peptide (i.e., the protein fragment of cobratide containing the N48 deamidation hotspot after enzymolysis) using an Orbitrap high-resolution mass spectrometer to quantify deamidated cobratide. The limits of detection and quantification of this method reached 0.02 and 0.025 µM, respectively, and inter- and intra-day precision values of the method were <3%. The accuracy of the 18O-labelling strategy was validated by using samples containing synthesised peptides with a known ratio of deamidation impurities and also by comparing the final total deamidation results with our previously developed capillary electrophoresis method. The recoveries for deamidation (Asp), deamidation isomerisation (iso-Asp), and total deamidation were 101.52 ± 1.17, 102.42 ± 1.82, and 103.55 ± 1.07, respectively. The robustness of the method was confirmed by verifying the chromatographic parameters. Our results demonstrate the applicability of the 18O-labelling strategy for detecting protein deamidation and lay a robust foundation for protein therapeutics studies and drug quality consistency evaluations.