Pulsed field ablation as first-line treatment to reduce atrial fibrillation burden documented by pacemaker.
Chen, Shaojie; Schmidt, Boris; Bordignon, Stefano; Tohoku, Shota; Urbanek, Lukas; Chun, Julian K R.
Affiliation
  • Chen S; Cardioangiologisches Centrum Bethanien (CCB), Frankfurt, Academy For Arrhythmias (FAFA), Kardiologie, Medizinische Klinik III, Agaplesion Markus Krankenhaus, Akademisches Lehrkrankenhaus der Goethe-Universität Frankfurt am Main, Frankfurt am Main, Germany.
  • Schmidt B; Die Sektion Medizin, Universität zu Lübeck, Lübeck, Germany.
  • Bordignon S; Cardioangiologisches Centrum Bethanien (CCB), Frankfurt, Academy For Arrhythmias (FAFA), Kardiologie, Medizinische Klinik III, Agaplesion Markus Krankenhaus, Akademisches Lehrkrankenhaus der Goethe-Universität Frankfurt am Main, Frankfurt am Main, Germany.
  • Tohoku S; Cardioangiologisches Centrum Bethanien (CCB), Frankfurt, Academy For Arrhythmias (FAFA), Kardiologie, Medizinische Klinik III, Agaplesion Markus Krankenhaus, Akademisches Lehrkrankenhaus der Goethe-Universität Frankfurt am Main, Frankfurt am Main, Germany.
  • Urbanek L; Cardioangiologisches Centrum Bethanien (CCB), Frankfurt, Academy For Arrhythmias (FAFA), Kardiologie, Medizinische Klinik III, Agaplesion Markus Krankenhaus, Akademisches Lehrkrankenhaus der Goethe-Universität Frankfurt am Main, Frankfurt am Main, Germany.
  • Chun JKR; Cardioangiologisches Centrum Bethanien (CCB), Frankfurt, Academy For Arrhythmias (FAFA), Kardiologie, Medizinische Klinik III, Agaplesion Markus Krankenhaus, Akademisches Lehrkrankenhaus der Goethe-Universität Frankfurt am Main, Frankfurt am Main, Germany.
Pacing Clin Electrophysiol ; 46(5): 414-418, 2023 05.
Article in En | MEDLINE | ID: mdl-36424836
ABSTRACT
Pulsed field ablation (PFA) using high-voltage electrical energy is a novel and powerful ablation modality. However, PFA as a first-line rhythm control in atrial fibrillation (AF) has been rarely described; whether PFA interacts with the pacemaker (PM) has been seldom reported. We reported PFA of AF in a patient with PM who needed effective rhythm control. Pulmonary vein isolation (PVI) was successfully performed without complication, and the procedure was extremely fast (skin-to-skin 25 min.) with short fluoroscopic time (3.9 min). PFA had no influence on the PM function. Six months' follow-up showed good clinical outcome and significantly decreased AF burden.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pulmonary Veins / Atrial Fibrillation / Catheter Ablation Limits: Humans Language: En Journal: Pacing Clin Electrophysiol Year: 2023 Type: Article Affiliation country: Germany