Your browser doesn't support javascript.
loading
Array electrochemiluminescence device with ultra-high sensitivity and selectivity for rapid visualized monitoring of trace radon in environment.
Wang, Ziyu; Li, Yulin; Pan, Jian-Bin; Xu, Meiyun; Xu, Jing-Juan; Hua, Daoben.
Affiliation
  • Wang Z; State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, 199 Ren'ai Road, Suzhou 215123, PR China.
  • Li Y; State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, 199 Ren'ai Road, Suzhou 215123, PR China.
  • Pan JB; State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, PR China.
  • Xu M; State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, 199 Ren'ai Road, Suzhou 215123, PR China.
  • Xu JJ; State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, PR China. Electronic address: xujj@nju.edu.cn.
  • Hua D; State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, 199 Ren'ai Road, Suzhou 215123, PR China; Collaborative Innovation Center of Radiological Medicine of Jiangsu, Higher Education Institutions, Soochow Univers
J Hazard Mater ; 453: 131449, 2023 Jul 05.
Article in En | MEDLINE | ID: mdl-37086673
ABSTRACT
The World Health Organization has reported radioactive Rn gas as the second leading cause of lung cancer and gives an extreme limit to indoor Radon (Rn) concentration as 100 Bq/m3. To realize rapid and accurate Rn monitoring, we report an efficient visualized electrochemiluminescence (ECL) device for Rn detection with the lowest limit of detection (0.9 Bq/m3/3.6 Bq h m-3) compared to known Rn detection methods and the shortest measurement time (less than 5 h) among non-pump methods. In detail, an efficient Rn probe is prepared by Au nanoparticles, Pb2+ aptamer, as well as NH2-ssDNA co-reactant and then modified on ITO electrodes to obtain Rn detection devices. With tris(2,2'-bipyridyl)ruthenium(II)chloride (Ru(bpy)3Cl2) as an ECL emitter, the devices can exhibit ultra-high sensitivity and selectivity to trace Rn in environment via the ECL quenching caused by 210Pb, the relatively stable decay product of Rn. Furthermore, ECL imaging technology can be applied to realize the visualized Rn detection. An efficient up-response ECL detector was also invented to support this detection device to achieve accurate Rn detection in environment. This work reports noble gas ECL detection for the first time and provides an efficient strategy for rapid and accurate monitoring of trace Rn in environment.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: J Hazard Mater Journal subject: SAUDE AMBIENTAL Year: 2023 Type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies Language: En Journal: J Hazard Mater Journal subject: SAUDE AMBIENTAL Year: 2023 Type: Article