Ranging analysis of a moving target based on the dynamic instrument response function.
Opt Lett
; 48(21): 5487-5490, 2023 Nov 01.
Article
in En
| MEDLINE
| ID: mdl-37910684
ABSTRACT
A ranging high-speed moving target with a high accuracy is challenging for a single-photon ranging system (SPRS). In this Letter, the dynamic instrument response function (IRF) is proposed to establish a dynamic discrete model (DDM) by introducing a velocity and a system timing resolution, which leads to better accuracy of cross-correlation results. And with the data of a dynamic Monte Carlo (DMC), the ranging accuracy can be improved with DDM.