Your browser doesn't support javascript.
loading
Optimization of a pre-concentration method for the analysis of mercury isotopes in low-concentration foliar samples.
Ali, Saeed Waqar; Bozic, Dominik; Vijayakumaran Nair, Sreekanth; Zivkovic, Igor; Gacnik, Jan; Andron, Teodor-Daniel; Jagodic Hudobivnik, Marta; Kocman, David; Horvat, Milena.
Affiliation
  • Ali SW; Jozef Stefan Institute, 1000, Ljubljana, Slovenia.
  • Bozic D; Jozef Stefan International Postgraduate School, 1000, Ljubljana, Slovenia.
  • Vijayakumaran Nair S; Jozef Stefan Institute, 1000, Ljubljana, Slovenia.
  • Zivkovic I; Jozef Stefan International Postgraduate School, 1000, Ljubljana, Slovenia.
  • Gacnik J; Jozef Stefan Institute, 1000, Ljubljana, Slovenia.
  • Andron TD; Jozef Stefan International Postgraduate School, 1000, Ljubljana, Slovenia.
  • Jagodic Hudobivnik M; Jozef Stefan Institute, 1000, Ljubljana, Slovenia.
  • Kocman D; Jozef Stefan International Postgraduate School, 1000, Ljubljana, Slovenia.
  • Horvat M; Jozef Stefan Institute, 1000, Ljubljana, Slovenia.
Anal Bioanal Chem ; 416(5): 1239-1248, 2024 Feb.
Article in En | MEDLINE | ID: mdl-38193932
ABSTRACT
Hg isotope analysis in samples from background regions is constrained by the presence of low Hg concentration and therefore requires a pre-concentration method. Existing Hg pre-concentration methods are constrained by long sample processing time and limited sample loading capacity. Using foliar samples as a test case, an optimized Hg pre-concentration method is presented that involves the microwave-assisted digestion of samples for Hg isotope analysis with the addition of a pre-digestion step. Microwave-digested foliar samples and CRMs were transferred to an impinger, reduced with SnCl2, and collected in a 2.25 mL concentrated inverse aqua regia (31 HNO3HCl, v/v). This resulted in an optimal acid concentration in the solution ideal for analysis on MC-ICP-MS. The time for purging with Hg-free N2 was optimized to 30 min and the efficiency of the pre-concentration method was tested using a combination of approaches. Tests performed on pure reagents and matrix of foliar samples spiked with 197Hg radiotracer showed recoveries averaging 99 ± 1.7% and 100 ± 3.0%, respectively. Mercury at concentrations as low as 1.83 ng g-1 was pre-concentrated by digesting aliquots of foliage samples in individual digestion vessels. Recoveries following their pre-concentration averaged 99 ± 6.0%, whereas recoveries of 95 ± 4.7% and 95 ± 2.5% were achieved for NIST SRM 1575a (pine needle) and reagents spiked with NIST SRM 3133, respectively. Analysis using multicollector-ICP-MS showed low fractionation of δ202Hg during sample pre-concentration with no significant mass-independent fractionation. The proposed method is a relatively simple and robust way to prepare Hg samples for Hg isotopic analysis and is suitable even for complex biological matrices.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Mercury Language: En Journal: Anal Bioanal Chem Year: 2024 Type: Article Affiliation country: Slovenia

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Mercury Language: En Journal: Anal Bioanal Chem Year: 2024 Type: Article Affiliation country: Slovenia