IDEAL-IQ combined with intravoxel incoherent motion diffusion-weighted imaging for quantitative diagnosis of osteoporosis.
Yang, Zhe; Liu, Chenglong; Shi, Zhaojuan; Qin, Jian.
Affiliation
  • Yang Z; Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an, Shandong, 271000, China.
  • Liu C; Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an, Shandong, 271000, China.
  • Shi Z; Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an, Shandong, 271000, China.
  • Qin J; Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, Tai'an, Shandong, 271000, China. sdqinjian@126.com.
BMC Med Imaging ; 24(1): 155, 2024 Jun 20.
Article in En | MEDLINE | ID: mdl-38902641
ABSTRACT

BACKGROUND:

Osteoporosis (OP) is a common chronic metabolic bone disease characterized by decreased bone mineral content and microstructural damage, leading to increased fracture risk. Traditional methods for measuring bone density have limitations in accurately distinguishing vertebral bodies and are influenced by vertebral degeneration and surrounding tissues. Therefore, novel methods are needed to quantitatively assess changes in bone density and improve the accurate diagnosis of OP.

METHODS:

This study aimed to explore the applicative value of the iterative decomposition of water and fat with echo asymmetry and least-squares estimation-iron (IDEAL-IQ) sequence combined with intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) for the diagnosis of osteoporosis. Data from 135 patients undergoing dual-energy X-ray absorptiometry (DXA), IDEAL-IQ, and IVIM-DWI were prospectively collected and analyzed. Various parameters obtained from IVIM-DWI and IDEAL-IQ sequences were compared, and their diagnostic efficacy was evaluated.

RESULTS:

Statistically significant differences were observed among the three groups for FF, R2*, f, D, DDC values, and BMD values. FF and f values exhibited negative correlations with BMD values, with r=-0.313 and - 0.274, respectively, while R2*, D, and DDC values showed positive correlations with BMD values, with r = 0.327, 0.532, and 0.390, respectively. Among these parameters, D demonstrated the highest diagnostic efficacy for osteoporosis (AUC = 0.826), followed by FF (AUC = 0.713). D* exhibited the lowest diagnostic performance for distinguishing the osteoporosis group from the other two groups. Only D showed a significant difference between genders. The AUCs for IDEAL-IQ, IVIM-DWI, and their combination were 0.74, 0.89, and 0.90, respectively.

CONCLUSIONS:

IDEAL-IQ combined with IVIM-DWI provides valuable information for the diagnosis of osteoporosis and offers evidence for clinical decisions. The superior diagnostic performance of IVIM-DWI, particularly the D value, suggests its potential as a more sensitive and accurate method for diagnosing osteoporosis compared to IDEAL-IQ. These findings underscore the importance of integrating advanced imaging techniques into clinical practice for improved osteoporosis management and highlight the need for further research to explore the full clinical implications of these imaging modalities.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Osteoporosis / Absorptiometry, Photon / Bone Density / Diffusion Magnetic Resonance Imaging Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: BMC Med Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2024 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Osteoporosis / Absorptiometry, Photon / Bone Density / Diffusion Magnetic Resonance Imaging Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: BMC Med Imaging Journal subject: DIAGNOSTICO POR IMAGEM Year: 2024 Type: Article Affiliation country: China