Your browser doesn't support javascript.
loading
Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)-Requirements, design, and performance.
Nyholm, P R; Palmer, N E; Petre, R B; Carpenter, A C; Nagel, S R; Bradley, D K; Vennari, C E; Golick, B; Boyle, D; Sharp, A M; Morioka, S B; Mackinnon, A J; Benedetti, L R.
Affiliation
  • Nyholm PR; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Palmer NE; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Petre RB; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Carpenter AC; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Nagel SR; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Bradley DK; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Vennari CE; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Golick B; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Boyle D; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Sharp AM; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Morioka SB; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Mackinnon AJ; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Benedetti LR; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
Rev Sci Instrum ; 95(7)2024 Jul 01.
Article in En | MEDLINE | ID: mdl-39041902
ABSTRACT
The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. We also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Rev Sci Instrum Year: 2024 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Rev Sci Instrum Year: 2024 Type: Article Affiliation country: United States