Your browser doesn't support javascript.
loading
Initial experience of a novel ergonomic surgical chair for laparoscopic pelvic surgery
Kim, Fernando J; Sehrt, David E; Molina, Wilson R; Huh, Jung-Sik; Rassweiler, Jens; Turner, Craig.
Afiliación
  • Kim, Fernando J; University of Colorado. US
  • Sehrt, David E; University of Colorado. US
  • Molina, Wilson R; University of Colorado. US
  • Huh, Jung-Sik; University of Colorado. US
  • Rassweiler, Jens; University of Colorado. US
  • Turner, Craig; University of Colorado. US
Int. braz. j. urol ; 37(4): 455-460, July-Aug. 2011. ilus, tab
Article en En | LILACS | ID: lil-600809
Biblioteca responsable: BR1.1
ABSTRACT

INTRODUCTION:

We present the initial experience of a novel surgical chair for laparoscopic pelvic surgery, the ETHOS TM (Bridge City Surgical, Portland, OR). MATERIALS AND

METHODS:

The ETHOS chair has an adjustable saddle height that ranges from 0.89 to 1.22 m high, an overall width of 0.89 m, and a depth of 0.97 m. The open straddle is 0.53 m and fits most OR tables. We performed 7 pelvic laparoscopy cases with the 1st generation ETHOS TM platform including 2 laparoscopic ureteral reimplantations, 5 laparoscopic pelvic lymphadenectomies for staging prostate cancer in which one case involved a laparoscopic radical retropubic prostatectomy, performed by 2 different surgeons.

RESULTS:

All 7 pelvic laparoscopic procedures were successful with the ETHOS TM chair. No conversion to open surgery was necessary. Survey done by surgeons after the procedures revealed minimal stress on back or upper extremities by the surgeons from these operations even when surgery was longer than 120 minutes. Conversely, the surgical assistants still had issues with their positions since they were on either sides of the patient stressing their positions during the procedure.

CONCLUSION:

The ETHOS chair system allows the surgeon to operate seated in comfortable position with ergonomic chest, arms, and back supports. These supports minimize surgeon fatigue and discomfort during pelvic laparoscopic procedures even when these procedures are longer than 120 minutes without consequence to the patient safety or detrimental effects to the surgical team.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: LILACS Asunto principal: Pelvis / Procedimientos Quirúrgicos Urológicos / Equipo Quirúrgico / Laparoscopía / Ergonomía Tipo de estudio: Evaluation_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Int. braz. j. urol Asunto de la revista: UROLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: LILACS Asunto principal: Pelvis / Procedimientos Quirúrgicos Urológicos / Equipo Quirúrgico / Laparoscopía / Ergonomía Tipo de estudio: Evaluation_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Int. braz. j. urol Asunto de la revista: UROLOGIA Año: 2011 Tipo del documento: Article País de afiliación: Estados Unidos