ABSTRACT

OBJECTIVE:

Spectral EEG analysis has been claimed to reduce subjective variability in EEG assessment of hepatic encephalopathy and to allow the detection of mild encephalopathy.

METHOD:

To test such assumptions, 43 digital EEG were recorded in 32 cirrhotics without overt encephalopathy or with grade 1 overt encephalopathy; 7 patients were re-tested (2-5 times) in their follow up. All patients underwent psychometric assessment. Nineteen controls were considered. EEG were blindly evaluated by two electroencephalographers and by spectral EEG analysis performed according to 3 different techniques.

RESULTS:

The reliability of the classification based on spectral analysis (biparietal technique) was higher than that based on a three-degree qualitative visual reading (concordance/discordance = 58/4 versus 46/16 P < 0.01) and comparable with that of semiquantitative visual assessment based on posterior basic rhythm (concordance/discordance = 55/7 P = 0.5). The accuracy of spectral EEG analysis was higher than that of qualitative visual EEG readings alone (90 versus 75%) and comparable to semi-quantitative visual assessment (87%), however, statistical significance was not reached. In the follow-up, the variations of theta and delta relative power were found to be significantly correlated with psychometric variations.

CONCLUSIONS:

In conclusion, spectral EEG analysis may improve the assessment of mild hepatic encephalopathy by decreasing inter-operator variability and providing reliable parameters correlated with mental status.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Encefalopatía Hepática / Electroencefalografía Tipo de estudio: Qualitative_research Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Neurophysiol Asunto de la revista: NEUROLOGIA / PSICOFISIOLOGIA Año: 1999 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Encefalopatía Hepática / Electroencefalografía Tipo de estudio: Qualitative_research Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Neurophysiol Asunto de la revista: NEUROLOGIA / PSICOFISIOLOGIA Año: 1999 Tipo del documento: Article País de afiliación: Italia