ABSTRACT

OBJECTIVE:

To determine whether using a small tidal volume (5 ml/kg) ventilation following sustained inflation with positive endexpiratory pressure (PEEP) set above the critical closing pressure (CCP) allows oxygenation equally well and induces as little lung damage as high-frequency oscillation following sustained inflation with a continuous distending pressure (CDP) slightly above the CCP of the lung. MATERIAL AND

METHODS:

Twelve surfactant-depleted adult New Zealand rabbits were ventilated for 4 h after being randomly assigned to one of two groups group 1, conventional mechanical ventilation, tidal volume 5 ml/kg, sustained inflation followed by PEEP > CCP; group 2, high-frequency oscillation, sustained inflation followed by CDP > CCP.

RESULTS:

In both groups oxygenation improved substantially after sustained inflation (P < 0.05) and remained stable over 4 h of ventilation without any differences between the groups. Histologically, both groups showed only little airway injury to bronchioles, alveolar ducts, and alveolar airspace, with no difference between the two groups. Myeloperoxidase content in homogenized lung tissue, as a marker of leukocyte infiltration, was equivalent in the two groups.

CONCLUSIONS:

We conclude that a volume recruitment strategy during small tidal volume ventilation and maintaining lung volumes above lung closing is as protective as that of high-frequency oscillation at similar lung volumes in this model of lung injury
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Síndrome de Dificultad Respiratoria / Ventilación de Alta Frecuencia / Mecánica Respiratoria / Ventilación con Presión Positiva Intermitente Límite: Animals Idioma: En Revista: Intensive Care Med Año: 2000 Tipo del documento: Article País de afiliación: Suiza
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Síndrome de Dificultad Respiratoria / Ventilación de Alta Frecuencia / Mecánica Respiratoria / Ventilación con Presión Positiva Intermitente Límite: Animals Idioma: En Revista: Intensive Care Med Año: 2000 Tipo del documento: Article País de afiliación: Suiza