Targeting aerosol deposition in patients with cystic fibrosis: effects of alterations in particle size and inspiratory flow rate.
Laube, B L; Jashnani, R; Dalby, R N; Zeitlin, P L.
Afiliación
  • Laube BL; Johns Hopkins Medical Institutions, and the University of Maryland, Baltimore, MD, USA. blaube@welchlink.welch.jhu.edu
Chest ; 118(4): 1069-76, 2000 Oct.
Article en En | MEDLINE | ID: mdl-11035679
ABSTRACT
STUDY

OBJECTIVE:

To determine if aerosolized medications can be targeted to deposit in the smaller, peripheral airways or the larger, central airways of adult cystic fibrosis (CF) patients by varying particle size and inspiratory flow rate.

DESIGN:

Randomized clinical trial.

SETTING:

Outpatient research laboratory. PATIENTS Nine adult patients with CF.

INTERVENTIONS:

Patients inhaled an aerosol comprised of 3.68+/-0.04 microm saline solution droplets (two visits) or 1.01+/- 0.2 microm saline solution droplets (two visits) for 30 s, starting from functional residual capacity and breathing at a slow or faster inspiratory flow rate. On all visits, the saline solution was admixed with the radioisotope (99m)Tc. Immediately after inhalation, a gamma camera recorded the deposition pattern of the radioaerosol in the lungs. Deposition images were analyzed in terms of the innerouter zone (IO) ratio, a measure of deposition in an inner zone (large, central airways) vs. an outer zone (small airways and alveoli). MEASUREMENTS AND

RESULTS:

For the 3.68-microm aerosol, IO ratios averaged 2.29+/-1.45 and 2.54+/-1.48 (p>0.05), indicating that aerosol distribution within the lungs was unchanged while breathing at 12+/-2 L/min vs. 31+/-5 L/min, respectively. For the 1.01-microm aerosol, IO ratios averaged 2.09+/-0.96 and 3.19+/-1.95 (p<0.05), indicating that deposition was predominantly in the smaller airways while breathing at 18+/-5 L/min and in the larger airways while breathing at 38+/-8 L/min, respectively.

CONCLUSIONS:

These results suggest that the targeted delivery of an aerosol to the smaller, peripheral airways or the larger, central airways of adult CF patients may be achieved by generating an aerosol comprised of approximately 1.0-microm particles and inspiring from functional residual capacity at approximately 18 L/min and approximately 38 L/min, respectively.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Pentetato de Tecnecio Tc 99m / Radiofármacos / Fibrosis Quística Tipo de estudio: Clinical_trials Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Chest Año: 2000 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Pentetato de Tecnecio Tc 99m / Radiofármacos / Fibrosis Quística Tipo de estudio: Clinical_trials Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Chest Año: 2000 Tipo del documento: Article País de afiliación: Estados Unidos