Serial serum digoxin concentrations and quantitative electrocardiographic changes.
Clin Pharmacol Ther ; 18(6): 757-60, 1975 Dec.
Article en En | MEDLINE | ID: mdl-1204281
ABSTRACT
Four elderly female patients in sinus rhythm and with mild congestive cardiac failure were treated with digoxin and studied over a 6-month period. There were significant linear correlations between serum digoxin concentrations and several quantitative electrocardiographic (ECG) parameters. T-wave amplitude was the most important ECG variable. ECG changes reverted to baseline values when digoxin was discontinued. These findings suggest that quantitative ECG changes are potentially useful in clinical and research situations involving digitalis glycosides.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Digoxina Límite: Aged / Female / Humans Idioma: En Revista: Clin Pharmacol Ther Año: 1975 Tipo del documento: Article