Determination of metallic impurities in a silicon wafer by local etching and electrothermal atomic absorption spectrometry.
Anal Sci
; 19(7): 1051-4, 2003 Jul.
Article
en En
| MEDLINE
| ID: mdl-12880091
An etching technique for the determination of the metallic impurities distribution in silicon wafers has been developed. An area of 10 mmphi and 10 microm depth was etched by 100 microL of an etching solution with a HF and HNO3 mixture. The acid matrix was evaporated on the wafer surface by IR lamp illumination and vacuum exhaust. Metallic impurities remaining on the wafer surface were redissolved into the collection solution, which was measured by electrothermal atomic absorption spectrometry (ET-AAS). The recovery invested by local etching/ET-AAS was within 95 - 112% for Fe, Cu and Ni. The detection limit (3sigma) for Fe, Cu and Ni in silicon was 1 x 10(13) atoms/cm3. To confirm the applicability, local etching was applied to evaluate the effects of metallic impurities in a gettering study and the electronic properties of semiconductor devices. It was found that local etching is a useful sample preparation technique for the analysis of metallic impurities in a specific area on a silicon wafer.
Buscar en Google
Colección:
01-internacional
Banco de datos:
MEDLINE
Idioma:
En
Revista:
Anal Sci
Año:
2003
Tipo del documento:
Article