Your browser doesn't support javascript.
loading
A new nonfluoroscopic navigation system to guide pulmonary vein isolation.
Tondo, Claudio; Mantica, Massimo; Russo, Giovanni; Karapatsoudi, Eleni; Lucchina, Arianna; Nigro, Franco; Wild, Michaela; Molinaro, Cristina; Bavila, Roberto.
Afiliación
  • Tondo C; Cardiac Arrhythmia Center, St. Ambrogio's Clinical Institute, University of Milan, Milan, Italy. claudio.tondo@grupposandonato.it
Pacing Clin Electrophysiol ; 28 Suppl 1: S102-5, 2005 Jan.
Article en En | MEDLINE | ID: mdl-15683472
ABSTRACT
Different techniques have been proposed to treat atrial fibrillation (AF) by catheter ablation. This study compares a new three-dimensional (3D) nonfluoroscopic navigation system with conventional fluoroscopy to guide pulmonary vein (PV) isolation. A total of 60 consecutive patients with paroxysmal or persistent AF were randomly assigned to 3D-guided ablation (group 1, n = 30), versus conventional fluoroscopy guidance ablation (group 2, n = 30). Complete PV isolation was achieved in both groups. The mean duration of fluoroscopy exposure (22 +/- 8 vs 56 +/- 10 minutes), and radiofrequency delivery (5 +/- 1 vs 10 +/- 3 minutes) were significantly shorter in group 1 than in group 2, P < 0.05 for both comparisons). The mean procedural time in group 1 was longer (225 +/- 15 minutes) than in group 2 (156 +/- 10 minutes, P < 0.05) due to the learning curve and time spent to generate the 3D maps. Over a mean follow-up of 7 +/- 2 months, 6 patients (20%) in group 2 had AF recurrences compared to 3 patients (10%) in group 1 (ns). The new nonfluoroscopic 3D system allows a high-resolution reconstruction of the left atrium and PVs. It significantly reduces the mean radiofrequency delivery and fluoroscopy times as opposed to ablation performed under fluoroscopy guidance.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Venas Pulmonares / Fibrilación Atrial / Ablación por Catéter / Atrios Cardíacos Tipo de estudio: Clinical_trials Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Año: 2005 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Venas Pulmonares / Fibrilación Atrial / Ablación por Catéter / Atrios Cardíacos Tipo de estudio: Clinical_trials Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Año: 2005 Tipo del documento: Article País de afiliación: Italia