Your browser doesn't support javascript.
loading
"Over-the-wire" inversion saphenectomy: a simple, minimally invasive vein harvesting technique for arterial bypass.
Hill, Bradley B; Faruqi, Rishad M; Arko, Frank R; Zarins, Christopher K; Fogarty, Thomas J.
Afiliación
  • Hill BB; Division of Vascular Surgery, Stanford University Medical Center, Stanford, California 94305-5642, USA. bhill@stanford.edu
J Endovasc Ther ; 12(3): 394-400, 2005 Jun.
Article en En | MEDLINE | ID: mdl-15943517
ABSTRACT

PURPOSE:

To examine the feasibility and clinical outcome of a novel, minimally invasive technique for harvesting the great saphenous vein (GSV) for use in peripheral arterial bypass surgery.

METHODS:

Between May 2001 through March 2003, 27 patients (15 men; mean age 71+/-10 years) underwent extremity bypass procedures for limb salvage (88%) or disabling claudication (12%) using the inversion technique to harvest the GSV. The veins were turned "inside out" using a unique catheter and guidewire system. With the endothelial surface exposed, valve leaflets were excised, and adherent thrombus was washed away. Veins were inverted again to turn the endothelial surface back inside the lumen for use as a bypass conduit.

RESULTS:

Inversion vein harvesting and arterial bypass were completed in 24 (89%) of 27 patients; 2 patients were treated with synthetic grafts because of small GSVs. Another patient was found after vein harvesting to have inadequate arterial outflow despite a good quality conduit. The average vein length was 45+/-10 cm; a mean 4+/-1 incisions were made, including those for arterial exposure. Incisions made to divide vein tributaries averaged 2 cm in length. Duration of vein harvesting was 25 minutes (range 5-80). Wound complications were minor (2 hematomas, 2 cases of erythema, 2 seromas). Of 6 grafts that occluded after 30 days, 5 involved small-diameter vein grafts (< 3.5 mm). At a mean 12 months, primary and assisted primary graft patency rates were 88% (14/16) and 94% (15/ 16), respectively, for grafts with minimum diameters > or = 4 mm versus 38% (3/8) primary patency for veins < 4 mm (n = 8, p < 0.001). The limb salvage rate was 92% (22/24).

CONCLUSIONS:

Over-the-wire inversion saphenectomy is a simple and reliable minimally invasive technique for arterial bypass. Incisions are small and cosmetically superior to those of the traditional long incision method. One-year follow-up suggests that grafts harvested by inversion technique have excellent durability when the minimum vein diameter is > or = 4 mm, as determined by preoperative vein mapping.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Vena Safena / Procedimientos Quirúrgicos Mínimamente Invasivos / Recolección de Tejidos y Órganos / Recuperación del Miembro / Arteria Femoral / Claudicación Intermitente Tipo de estudio: Observational_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Endovasc Ther Asunto de la revista: ANGIOLOGIA Año: 2005 Tipo del documento: Article País de afiliación: Estados Unidos
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Vena Safena / Procedimientos Quirúrgicos Mínimamente Invasivos / Recolección de Tejidos y Órganos / Recuperación del Miembro / Arteria Femoral / Claudicación Intermitente Tipo de estudio: Observational_studies / Prognostic_studies Límite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Endovasc Ther Asunto de la revista: ANGIOLOGIA Año: 2005 Tipo del documento: Article País de afiliación: Estados Unidos