Your browser doesn't support javascript.
loading
Antithrombin significantly influences platelet adhesion onto immobilized fibrinogen in an in-vitro system simulating low flow.
Loncar, Robert; Kalina, Uwe; Stoldt, Volker; Thomas, Volker; Scharf, Rüdiger E; Vodovnik, Aleksandar.
Afiliación
  • Loncar R; Department of Hemostasis and Transfusion Medicine, Heinrich Heine University Medical Center Duesseldorf, Germany. Loncar@med.uni-duesseldorf.de
Thromb J ; 4: 19, 2006 Oct 13.
Article en En | MEDLINE | ID: mdl-17040572
BACKGROUND: Adhesion of platelets onto immobilized fibrinogen is of importance in initiation and development of thrombosis. According to a recent increase in evidence of a multiple biological property of antithrombin, we evaluated the influence of antithrombin on platelet adhesion onto immobilized fibrinogen using an in-vitro flow system. METHODS: Platelets in anticoagulated whole blood (29 healthy blood donors) were labelled with fluorescence dye and perfused through a rectangular flow chamber (shear rates of 13 s-1 to 1500 s-1). Platelet adhesion onto fibrinogen-coated slips was assessed using a fluorescence laser-scan microscope and compared to the plasma antithrombin activity. Additionally the effect of supraphysiological AT supplementation on platelets adhesion rate was evaluated. RESULTS: Within a first minute of perfusion, an inverse correlation between platelet adhesion and plasma antithrombin were observed at 13 s-1 and 50 s-1 (r = -0.48 and r = -0.7, p < 0.05, respectively). Significant differences in platelet adhesion related to low (92 +/- 3.3%) and high (117 +/- 4.1%) antithrombin activity (1786 +/- 516 U vs. 823 +/- 331 U, p < 0.05) at low flow rate (13 s-1, within first minute) have been found. An in-vitro supplementation of whole blood with antithrombin increased the antithrombin activity up to 280% and platelet adhesion rate reached about 65% related to the adhesion rate in a non-supplemented blood (1.25 +/- 0.17 vs. 1.95 +/- 0.4 p = 0.008, respectively). CONCLUSION: It appears that antithrombin in a low flow system suppresses platelet adhesion onto immobilized fibrinogen independently from its antithrombin activity. A supraphysiological substitution of blood with antithrombin significantly reduces platelet adhesion rate. This inhibitory effect might be of clinical relevance.

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Thromb J Año: 2006 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Idioma: En Revista: Thromb J Año: 2006 Tipo del documento: Article País de afiliación: Alemania