ABSTRACT

BACKGROUND:

Serum antinuclear antibodies giving the 'multiple nuclear dots' or the 'rim-like/membranous' patterns are frequently detected by indirect immunofluorescence on HEp-2 cells in patients with primary biliary cirrhosis.

AIM:

To assess the accuracy of multiple nuclear dot and rim-like/membranous antinuclear antibodies for the diagnosis of primary biliary cirrhosis.

METHODS:

Sera from 4371 consecutive patients referred to our laboratory were analysed under code for antinuclear antibodies testing by indirect immunofluorescence on HEp-2 cells.

RESULTS:

Review of the clinical records of the 4371 patients allowed identification of 101 patients with antimitochondrial antibody-positive primary biliary cirrhosis and 22 with antimitochondrial antibody-negative variant. Multiple nuclear dot and/or rim-like/membranous patterns were found in 59 (1.3%) of the 4371 patients 31 antimitochondrial antibody-positive primary biliary cirrhosis, 17 antimitochondrial antibody-negative primary biliary cirrhosis and 11 non-primary biliary cirrhosis. The specificity for primary biliary cirrhosis of both the antinuclear antibodies pattern was 99%. Positive predictive value and likelihood ratio for a positive test were 86% (95% CI 72.7-94) and 221 (95% CI 91.7-544) for multiple nuclear dot, 79% (95% CI 62.2-90.1) and 132 (95% CI 56.8-312.7) for rim-like/membranous, respectively.

CONCLUSIONS:

Multiple nuclear dot and rim-like/membranous antinuclear antibodies are rare findings. Their positivity strongly suggests the diagnosis of primary biliary cirrhosis, irrespective of antimitochondrial antibody status. The high specificity for primary biliary cirrhosis makes them a useful diagnostic tool especially in antimitochondrial antibody-negative patients.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Autoanticuerpos / Técnica del Anticuerpo Fluorescente Indirecta / Cirrosis Hepática Biliar Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Aliment Pharmacol Ther Asunto de la revista: FARMACOLOGIA / GASTROENTEROLOGIA / TERAPIA POR MEDICAMENTOS Año: 2006 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Autoanticuerpos / Técnica del Anticuerpo Fluorescente Indirecta / Cirrosis Hepática Biliar Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Aliment Pharmacol Ther Asunto de la revista: FARMACOLOGIA / GASTROENTEROLOGIA / TERAPIA POR MEDICAMENTOS Año: 2006 Tipo del documento: Article País de afiliación: Italia