Your browser doesn't support javascript.
loading
Combined functional and morphological imaging consisting of gated myocardial perfusion SPECT and 16-detector multislice spiral CT angiography in the noninvasive evaluation of coronary artery disease: first experiences.
Hacker, Marcus; Jakobs, Tobias; Matthiesen, Florian; Nikolaou, Konstantin; Becker, Christoph; Knez, Andreas; Tiling, Reinhold.
Afiliación
  • Hacker M; Department of Nuclear Medicine, University of Munich, Munich, Germany. marcus.hacker@med.uni-muenchen.de
Clin Imaging ; 31(5): 313-20, 2007.
Article en En | MEDLINE | ID: mdl-17825738
ABSTRACT

INTRODUCTION:

Appropriate diagnosis and therapy of coronary artery disease (CAD) frequently require information about both the functional and morphological status of the coronary artery tree. We hypothesized that the combination of multislice spiral CT (MDCT) angiography and myocardial perfusion SPECT (MPI) provides accurate allocation of perfusion defects (PD) to their determining coronary lesion.

METHODS:

Twenty patients (14 male, mean age 64+/-9.2 years) with known CAD were retrospectively studied. Gated MPI, CT angiography using a 16-detector CT scanner, and conventional coronary angiography (CCA) were performed in each patient. Reversible and fixed PD were subsequently allocated to their determining lesion separately by different observers for MDCT angiography and CCA.

RESULTS:

All patients showed significant CAD in CCA; six patients with one-, six with two-, six with three-, and two with four-vessel disease; three patients had bypass grafts; and five patients had prior myocardial infarction. Correct diagnosis of CAD was stated in 14 of 20 patients by MDCT angiography. Five reversible and five fixed PD were detected in 9 of 20 patients; one patient showed both reversible and fixed PD. Five of five reversible PD could be allocated to appropriate coronary artery stenoses in CCA. In MDCT angiography, five of five reversible PD were allocated to the same lesions; all lesions were rated as >/=50%.

CONCLUSIONS:

The preliminary results of the present study show high accuracy for multislice spiral CT angiography to allocate reversible perfusion defects in myocardial scintigraphy to their determining coronary artery lesions in a small patient collective with known coronary artery disease.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Imagen de Acumulación Sanguínea de Compuerta / Tomografía Computarizada de Emisión de Fotón Único / Técnica de Sustracción / Angiografía Coronaria / Tomografía Computarizada Espiral Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2007 Tipo del documento: Article País de afiliación: Alemania
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Imagen de Acumulación Sanguínea de Compuerta / Tomografía Computarizada de Emisión de Fotón Único / Técnica de Sustracción / Angiografía Coronaria / Tomografía Computarizada Espiral Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Imaging Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2007 Tipo del documento: Article País de afiliación: Alemania