ABSTRACT

BACKGROUND:

Conventional optical coherence tomography (OCT) has brought new insights to retinal diagnostics, but it is restricted due to its low scanning speed and limited resolution. In this study, high-resolution raster scanning OCT (HR-OCT) was used to identify typical changes in central serous chorioretinopathy (CSC).

METHODS:

Fifteen consecutive patients with acute CSC were imaged using HR-OCT with an axial image resolution of 6 mum. The scanned area measured 6x6 mm2. Three-dimensional (3D) evaluation was performed using various analysing programmes.

RESULTS:

Topographic changes in CSC could be visualised with 3D reconstructions in all locations. Retinal thickness was measured with the automatic segmentation mode and quantified precisely. Results were presented in 2D and 3D maps. En-face imaging as a modality to present an integrative overview showed specific alterations in CSC.

CONCLUSION:

HR-OCT was able to provide essential additional information about CSC when combined with appropriate analysing programmes, allowing the identification of typical differences. Aside from precise volumetric measurements, exact localisation of pathological deviations could be achieved.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Coriorretinitis / Imagenología Tridimensional / Tomografía de Coherencia Óptica Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: De Revista: Ophthalmologe Asunto de la revista: OFTALMOLOGIA Año: 2008 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Coriorretinitis / Imagenología Tridimensional / Tomografía de Coherencia Óptica Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: De Revista: Ophthalmologe Asunto de la revista: OFTALMOLOGIA Año: 2008 Tipo del documento: Article