Your browser doesn't support javascript.
loading
Interatrial mechanical dyssynchrony worsened atrial mechanical function in sinus node disease with or without paroxysmal atrial fibrillation.
Wang, Mei; Lau, Chu Pak; Zhang, Xue Hua; Siu, Chung-Wah; Lee, Kathy L F; Yan, Guo Hui; Yue, Wen Sheng; Tse, Hung Fat.
Afiliación
  • Wang M; Division of Cardiology, Department of Medicine, Queen Mary Hospital.
J Cardiovasc Electrophysiol ; 20(11): 1237-43, 2009 Nov.
Article en En | MEDLINE | ID: mdl-19602020
INTRODUCTION: Atrial electromechanical dysfunction might contribute to the development of atrial fibrillation (AF) in patients with sinus node disease (SND). The aim of this study was to investigate the prevalence and impact of atrial mechanical dyssynchrony on atrial function in SND patients with or without paroxysmal AF. METHODS: We performed echocardiographic examination with tissue Doppler imaging in 30 SND patients with (n = 11) or without (n = 19) paroxysmal AF who received dual-chamber pacemakers. Tissue Doppler indexes included atrial contraction velocities (Va) and timing events (Ta) were measured at midleft atrial (LA) and right atrial (RA) wall. Intraatrial synchronicity was defined by the standard deviation and maximum time delay of Ta among 6 segments of LA (septal/lateral/inferior/anterior/posterior/anterospetal). Interatrial synchronicity was defined by time delay between Ta from RA and LA free wall. RESULTS: There were no differences in age, P-wave duration, left ventricular ejection fraction, LA volume, and ejection fraction between with or without AF. Patients with paroxysmal AF had lower mitral inflow A velocity (70 +/- 19 vs 91 +/- 17 cm/s, P = 0.005), LA active empting fraction (24 +/- 14 vs 36 +/- 13%, P = 0.027), mean Va of LA (2.6 +/- 0.9 vs 3.4 +/- 0.9 cm/s, P = 0.028), and greater interatrial synchronicity (33 +/- 25 vs 12 +/- 19 ms, P = 0.022) than those without AF. Furthermore, a lower mitral inflow A velocity (Odd ratio [OR]= 1.12, 95% Confidence interval [CI] 1.01-1.24, P = 0.025) and prolonged interatrial dyssynchrony (OR = 1.08, 95% CI 1.01-1.16, P = 0.020) were independent predictors for the presence of AF in SND patients. CONCLUSION: SND patients with paroxysmal AF had reduced regional and global active LA mechanical contraction and increased interatrial dyssychrony as compared with those without AF. These findings suggest that abnormal atrial electromechanical properties are associated with AF in SND patients.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Arritmia Sinusal / Fibrilación Atrial / Disfunción Ventricular Izquierda Tipo de estudio: Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2009 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Arritmia Sinusal / Fibrilación Atrial / Disfunción Ventricular Izquierda Tipo de estudio: Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male País/Región como asunto: Asia Idioma: En Revista: J Cardiovasc Electrophysiol Asunto de la revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Año: 2009 Tipo del documento: Article