Characterization and sequence identification of angiotensin II by a novel method involving ultra-fast liquid chromatography assay coupled with matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight five tandem mass spectrometry analysis.
Zhao, Ning-wei; Yao, Jin-ting.
Afiliación
  • Zhao NW; Shimadzu Global COE for Application & Technical Development, Shanghai 200052, China. ningwei@kth.se
Eur J Mass Spectrom (Chichester) ; 16(6): 663-71, 2010.
Article en En | MEDLINE | ID: mdl-21173463
High-throughput proteomics aims to investigate dynamically changing proteins expressed by a full organism, specific tissue or cellular compartment under certain conditions. High-sensitivity mass spectrometry has gradually become a significant tool for characterizing peptides. Here, we analyzed angiotensin II using ultra-fast liquid chromatography (UFLC) coupled with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS). First, we applied UFLC in isolating and collecting the angiotensin II, and then Axima-Resonance (MALDI-QIT-ToF MS(5)) was adopted, which enables collision-induced dissociation-MS(5) analysis for fine structural characterization of angiotensin II. Resultant MS, MS(2), MS(3) and MS(4) spectra of interested [M+H](+) ions selected as precursor ions yielded detailed information about the sites of fragmentation as well as the amino acid sequence for angiotensin II; meanwhile, the average deviation between theoretical mass and actually measured mass from MS to MS(5) spectra was only 0.32 Da. It indicated that Axima-Resonance was capable of analyzing the peptide sequence accurately and provide the corresponding fragmentation information thoroughly, thus suggesting a potential strategy involving UFLC assay coupled with MALDI-QIT-ToF MS(5) analysis on high-throughput proteomics study in future.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Angiotensina II / Cromatografía Líquida de Alta Presión / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción / Análisis de Secuencia de Proteína / Espectrometría de Masa por Ionización de Electrospray Tipo de estudio: Diagnostic_studies Idioma: En Revista: Eur J Mass Spectrom (Chichester) Año: 2010 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Angiotensina II / Cromatografía Líquida de Alta Presión / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción / Análisis de Secuencia de Proteína / Espectrometría de Masa por Ionización de Electrospray Tipo de estudio: Diagnostic_studies Idioma: En Revista: Eur J Mass Spectrom (Chichester) Año: 2010 Tipo del documento: Article País de afiliación: China