Comparison between eight- and sixteen-channel TEM transceive arrays for body imaging at 7 T.
Snyder, C J; Delabarre, L; Moeller, S; Tian, J; Akgun, C; Van de Moortele, P-F; Bolan, P J; Ugurbil, K; Vaughan, J T; Metzger, G J.
Afiliación
  • Snyder CJ; Department of Radiology, University of Minnesota, Minneapolis, MN, USA.
Magn Reson Med ; 67(4): 954-64, 2012 Apr.
Article en En | MEDLINE | ID: mdl-22102483
ABSTRACT
Eight- and sixteen-channel transceive stripline/TEM body arrays were compared at 7 T (297 MHz) both in simulation and experiment. Despite previous demonstrations of similar arrays for use in body applications, a quantitative comparison of the two configurations has not been undertaken to date. Results were obtained on a male pelvis for assessing transmit, signal to noise ratio, and parallel imaging performance and to evaluate local power deposition versus transmit B(1) (B(1) (+) ). All measurements and simulations were conducted after performing local B(1) (+) phase shimming in the region of the prostate. Despite the additional challenges of decoupling immediately adjacent coils, the sixteen-channel array demonstrated improved or nearly equivalent performance to the eight-channel array based on the evaluation criteria. Experimentally, transmit performance and signal to noise ratio were 22% higher for the sixteen-channel array while significantly increased reduction factors were achievable in the left-right direction for parallel imaging. Finite difference time domain simulations demonstrated similar results with respect to transmit and parallel imaging performance, however, a higher transmit efficiency advantage of 33% was predicted. Simulations at both 3 and 7 T verified the expected parallel imaging improvements with increasing field strength and showed that, for a specific B(1) (+) shimming strategy used, the sixteen-channel array exhibited lower local and global specific absorption rate for a given B(1) (+) .
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Pelvis / Imagen por Resonancia Magnética Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Humans / Male Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Pelvis / Imagen por Resonancia Magnética Tipo de estudio: Prognostic_studies / Risk_factors_studies Límite: Humans / Male Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2012 Tipo del documento: Article País de afiliación: Estados Unidos