Your browser doesn't support javascript.
loading
Studying semblances of a true killer: experimental model of human ventricular fibrillation.
Nair, K; Farid, T; Masse, S; Umapathy, K; Watkins, S; Poku, K; Asta, J; Kusha, M; Sevaptsidis, E; Jacob, J; Floras, J S; Nanthakumar, K.
Afiliación
  • Nair K; Division of Cardiology, University Health Network, Toronto General Hospital, University of Toronto, Ontario, Canada.
Am J Physiol Heart Circ Physiol ; 302(7): H1533-7, 2012 Apr 01.
Article en En | MEDLINE | ID: mdl-22268105
ABSTRACT
It is unknown whether ventricular fibrillation (VF) studied in experimental models represents in vivo human VF. First, we examined closed chest in vivo VF induced at defibrillation threshold testing (DFT) in four patients with ischemic cardiomyopathy pretransplantation. We examined VF in these same four hearts in an ex vivo human Langendorff posttransplantation. VF from DFT was compared with VF from the electrodes from a similar region in the right ventricular endocardium in the Langendorff using two parameters the scale distribution width (extracted from continuous wavelet transform) and VF mean cycle length (CL). In a second substudy group where multielectrode phase mapping could be performed, we examined early VF intraoperatively (in vivo open chest condition) in three patients with left ventricular cardiomyopathy. We investigated early VF in the hearts of three patients in an ex vivo Langendorff and compared findings with intraoperative VF using two metrics dominant frequency (DF) assessed by the Welch periodogram and the number of phase singularities (lasting >480 ms). Wavelet analysis (P = 0.9) and VF CL were similar between the Langendorff and the DFT groups (225 ± 13, 218 ± 24 ms; P = 0.9), indicating that wave characteristics and activation rate of VF was comparable between the two models. Intraoperative DF was slower but comparable with the Langendorff DF over the endocardium (4.6 ± 0.1, 5.0 ± 0.4 Hz; P = 0.9) and the epicardium (4.5 ± 0.2, 5.2 ± 0.4 Hz; P = 0.9). Endocardial phase singularity number (9.6 ± 5, 12.1 ± 1; P = 0.6) was lesser in number but comparable between in vivo and ex vivo VF. VF dynamics in the limited experimental human studies approximates human in vivo VF.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fibrilación Ventricular Tipo de estudio: Prognostic_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Physiol Heart Circ Physiol Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2012 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fibrilación Ventricular Tipo de estudio: Prognostic_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Physiol Heart Circ Physiol Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2012 Tipo del documento: Article País de afiliación: Canadá