J-difference editing of gamma-aminobutyric acid (GABA): simulated and experimental multiplet patterns.
Near, Jamie; Evans, C John; Puts, Nicolaas A J; Barker, Peter B; Edden, Richard A E.
Afiliación
  • Near J; Douglas Mental Health University Institute and Department of Psychiatry, McGill University, Montreal, Canada; FMRIB Centre, University of Oxford, Oxford, UK.
Magn Reson Med ; 70(5): 1183-91, 2013 Nov.
Article en En | MEDLINE | ID: mdl-23213033
ABSTRACT

PURPOSE:

To investigate factors that influence the multiplet pattern observed in J-difference editing of gamma-aminobutyric acid (GABA).

METHODS:

Density matrix simulations were applied to investigate the shape of the 3 ppm GABA multiplet as a function of the editing sequence's slice-selective refocusing pulse properties, in particular bandwidth, transition width, and flip angle. For comparison to the calculations, experimental measurements were also made at 3 T on a 10 mM GABA solution using the MEGA-PRESS sequence at various refocusing pulse flip angles.

RESULTS:

Good agreement was found between experiments and simulations. The edited multiplet consists of two outer lines of slightly unequal intensity due to strong coupling, and a smaller central line, the result of the unequal J-couplings between the C4 and C3 protons. The size of the center peak increases with increasing slice-selective refocusing pulse transition width, and deviation of the flip angle from 180°.

CONCLUSION:

The 3 ppm GABA multiplet pattern observed in the MEGA-PRESS experiment depends quite strongly on the properties of the slice-selective refocusing pulses used. Under some circumstance, the central peak can be quite large; this does not necessarily indicate inefficient editing, or a subtraction artifact, but should be recognized as a property of the pulse sequence itself.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Algoritmos / Reconocimiento de Normas Patrones Automatizadas / Espectroscopía de Resonancia Magnética / Ácido gamma-Aminobutírico / Modelos Químicos Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2013 Tipo del documento: Article País de afiliación: Reino Unido

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Algoritmos / Reconocimiento de Normas Patrones Automatizadas / Espectroscopía de Resonancia Magnética / Ácido gamma-Aminobutírico / Modelos Químicos Tipo de estudio: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2013 Tipo del documento: Article País de afiliación: Reino Unido