Magnetic resonance susceptibility weighted phase imaging for the assessment of reperfusion intramyocardial hemorrhage.
Goldfarb, James W; Hasan, Usama; Zhao, Wenguo; Han, Jing.
Afiliación
  • Goldfarb JW; Department of Research and Education, Saint Francis Hospital, Roslyn, New York, USA; Program in Biomedical Engineering, SUNY Stony Brook, Stony Brook, New York, USA.
Magn Reson Med ; 71(3): 1210-20, 2014 Mar.
Article en En | MEDLINE | ID: mdl-23776036
PURPOSE: To quantitatively investigate myocardial phase in multiple-gradient-echo images to determine normal phase angle ranges as a function of echo time and anatomical position and then compare phase values from patients with myocardial infarction with those normal ranges to determine the feasibility of intramyocardial hemorrhage detection. METHODS: Fifteen normal control and 11 patients with reperfused myocardial infarction participated in this prospective study. A 1.5 T magnetic resonance system was used to perform volumetric CINE, high-pass filtered (HPF) phase, T2-weighted, T2*-weighted and late gadolinium-enhanced infarct imaging at four times points after myocardial infarction. HPF-phase analyzed using a 16-segment model was compared with late gadolinium-enhanced infarct imaging and T2* measurements. RESULTS: Myocardial HPF-phase angle in the normal control group was small (-0.008 ± 0.027 radians). There was a difference between anatomical segments, with less variation in septal segments compared with cyclic variations in non-septal segments. Abnormal phase was only shown in myocardial segments with transmural late gadolinium-enhanced and microvascular obstruction consistent with intramyocardial hemorrhage. There were six studies from three patients (seven segments at 3 days, five segments at follow-up) with HPF-phase outside of normal range indicative of intramyocardial hemorrhage. CONCLUSION: Myocardial HPF-phase angle is normally small and varies by anatomical myocardial segment. intramyocardial hemorrhage causes a phase decrease beyond normal variations.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Algoritmos / Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Daño por Reperfusión Miocárdica / Hemorragia Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Algoritmos / Imagen por Resonancia Magnética / Interpretación de Imagen Asistida por Computador / Aumento de la Imagen / Daño por Reperfusión Miocárdica / Hemorragia Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos