Spectrally resolved motional Stark effect measurements on ASDEX Upgrade.
Rev Sci Instrum
; 84(11): 113503, 2013 Nov.
Article
en En
| MEDLINE
| ID: mdl-24295436
ABSTRACT
A spectrally resolved Motional Stark Effect (MSE) diagnostic has been installed at ASDEX Upgrade. The MSE data have been fitted by a forward model providing access to information about the magnetic field in the plasma interior [R. Reimer, A. Dinklage, J. Geiger et al., Contrib. Plasma Phys. 50, 731-735 (2010)]. The forward model for the beam emission spectra comprises also the fast ion Dα signal [W. W. Heidbrink and G. J. Sadler, Nucl. Fusion 34, 535-615 (1994)] and the smearing on the CCD-chip. The calculated magnetic field data as well as the revealed (dia)magnetic effects are consistent with the results from equilibrium reconstruction solver. Measurements of the direction of the magnetic field are affected by unknown and varying polarization effects in the observation.
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Idioma:
En
Revista:
Rev Sci Instrum
Año:
2013
Tipo del documento:
Article
País de afiliación:
Alemania