The effect of open-irrigated radiofrequency catheter ablation of atrial fibrillation on left atrial pressure and B-type natriuretic peptide.
Seiler, Jens; Steven, Daniel; Roberts-Thomson, Kurt C; Inada, Keiichi; Tedrow, Usha B; Michaud, Gregory F; Stevenson, William G.
Afiliación
  • Seiler J; Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.
Pacing Clin Electrophysiol ; 37(5): 616-23, 2014 May.
Article en En | MEDLINE | ID: mdl-24372302
ABSTRACT

BACKGROUND:

Open-irrigated radiofrequency catheter ablation (oiRFA) of atrial fibrillation (AF) imposes a volume load and risk of pulmonary edema. We sought to assess the effect of volume administration during ablation on left atrial (LA) pressure and B-type natriuretic peptide (BNP).

METHODS:

LA pressure was measured via transseptal sheath at the beginning and end of 44 LA ablation procedures in 42 patients. BNP plasma levels were measured before and after 10 procedures.

RESULTS:

A median of 3,255 (interquartile range [IQR], 2,014)-mL saline was administered during the procedure. During LA ablation, the median fluid balance was +1,438 (IQR, 1,109) mL and LA pressure increased by median 3.7 (IQR, 5.9) mm Hg (P < 0.001). LA pressure did not change in the 19 procedures with furosemide administration (median ΔP = -0.3 [IQR, 7.1] mm Hg, P = 0.334). The correlation of LA pressure and fluid balance was weak (rs = 0.383, P = 0.021). BNP decreased in all four procedures starting in AF or atrial tachycardia and then converting to sinus rhythm (P = 0.068), and increased in all six procedures starting and finishing in sinus rhythm (P = 0.028). After ablation, symptomatic volume overload responding to diuresis occurred in three patients.

CONCLUSIONS:

A substantial intravascular volume load during oiRFA can be absorbed with little change in LA pressure, such that LA pressure is not a reliable indicator of the fluid balance. Subsequent redistribution of the volume load imposes a risk after the procedure. Conversion to sinus rhythm may improve ability to acutely accommodate the volume load.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fibrilación Atrial / Desequilibrio Hidroelectrolítico / Ablación por Catéter / Péptido Natriurético Encefálico / Presión Atrial Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Fibrilación Atrial / Desequilibrio Hidroelectrolítico / Ablación por Catéter / Péptido Natriurético Encefálico / Presión Atrial Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: Pacing Clin Electrophysiol Año: 2014 Tipo del documento: Article