Objectively determined refraction improves peripheral vision.
Lewis, Peter; Baskaran, Karthikeyan; Rosén, Robert; Lundström, Linda; Unsbo, Peter; Gustafsson, Jörgen.
Afiliación
  • Lewis P; *BOptom †PhD ‡PhD, FAAO Department of Medicine and Optometry, Linnæus University, Kalmar, Sweden (PL, KB, JG); and Biomedical and X-Ray Physics, KTH, Royal Institute of Technology, Stockholm, Sweden (RR, LL, PU).
Optom Vis Sci ; 91(7): 740-6, 2014 Jul.
Article en En | MEDLINE | ID: mdl-24927137
ABSTRACT

PURPOSE:

The purpose of this study was twofold to verify a fast, clinically applicable method for determining off-axis refraction and to assess the impact of objectively obtained off-axis refractive correction on peripheral low-contrast visual acuity.

METHODS:

We measured peripheral low-contrast resolution acuity with Gabor patches both with and without off-axis correction at 20 degrees in the nasal visual field of 10 emmetropic subjects; the correction was obtained using a commercial open-field Hartmann-Shack wavefront sensor, the COAS-HD VR aberrometer. Off-axis refractive errors were calculated for a 5-mm circular pupil inscribed within the elliptical wavefront by COAS using the instruments' inbuilt "Seidel sphere" method.

RESULTS:

Most of the subjects had simple myopic astigmatism, at 20 degrees in the nasal visual field ranging from -1.00 to -2.00 DC, with axis orientations generally near 90 degrees. The mean uncorrected and corrected low-contrast resolution acuities for all subjects were 0.92 and 0.86 logMAR, respectively (an improvement of 0.06 logMAR). For subjects with a scalar power refractive error of 1.00 diopters or more, the average improvement was 0.1 logMAR. The observed changes in low-contrast resolution acuity were strongly correlated with off-axis astigmatism (Pearson r = 0.95; p < 0.0001), the J180 cross-cylinder component (Pearson r = 0.82; p = 0.0034), and power scalar (Pearson r = -0.75; p = 0.0126).

CONCLUSIONS:

The results suggest that there are definite benefits in correcting even moderate amounts of off-axis refractive errors; in this study, as little as -1.50 DC of off-axis astigmatism gave improvements of up to a line in visual acuity. It may be even more pertinent for people who rely on optimal peripheral visual function, specifically those with central visual field loss; the use of open-field aberrometers could be clinically useful in rapidly determining off-axis refractive errors specifically for this patient group who are generally more challenging to refract.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Refracción Ocular / Agudeza Visual / Córnea / Miopía Tipo de estudio: Diagnostic_studies Límite: Adult / Humans Idioma: En Revista: Optom Vis Sci Asunto de la revista: OPTOMETRIA Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Refracción Ocular / Agudeza Visual / Córnea / Miopía Tipo de estudio: Diagnostic_studies Límite: Adult / Humans Idioma: En Revista: Optom Vis Sci Asunto de la revista: OPTOMETRIA Año: 2014 Tipo del documento: Article