Your browser doesn't support javascript.
loading
Harmonisation of short-term in vitro culture for the expansion of antigen-specific CD8(+) T cells with detection by ELISPOT and HLA-multimer staining.
Chudley, Lindsey; McCann, Katy J; Coleman, Adam; Cazaly, Angelica M; Bidmon, Nicole; Britten, Cedrik M; van der Burg, Sjoerd H; Gouttefangeas, Cecile; Jandus, Camilla; Laske, Karoline; Maurer, Dominik; Romero, Pedro; Schröder, Helene; Stynenbosch, Linda F M; Walter, Steffen; Welters, Marij J P; Ottensmeier, Christian H.
Afiliación
  • Chudley L; Cancer Sciences Unit, Faculty of Medicine, Experimental Cancer Medicine Centre, Southampton General Hospital, University of Southampton, Tremona Road, Southampton, SO16 6YD, UK, ll4@soton.ac.uk.
Cancer Immunol Immunother ; 63(11): 1199-211, 2014 Nov.
Article en En | MEDLINE | ID: mdl-25134947
ABSTRACT
Ex vivo ELISPOT and multimer staining are well-established tests for the assessment of antigen-specific T cells. Many laboratories are now using a period of in vitro stimulation (IVS) to enhance detection. Here, we report the findings of a multi-centre panel organised by the Association for Cancer Immunotherapy Immunoguiding Program to investigate the impact of IVS protocols on the detection of antigen-specific T cells of varying ex vivo frequency. Five centres performed ELISPOT and multimer staining on centrally prepared PBMCs from 3 donors, both ex vivo and following IVS. A harmonised IVS protocol was designed based on the best-performing protocol(s), which was then evaluated in a second phase on 2 donors by 6 centres. All centres were able to reliably detect antigen-specific T cells of high/intermediate frequency both ex vivo (Phase I) and post-IVS (Phase I and II). The highest frequencies of antigen-specific T cells ex vivo were mirrored in the frequencies following IVS and in the detection rates. However, antigen-specific T cells of a low/undetectable frequency ex vivo were not reproducibly detected post-IVS. Harmonisation of the IVS protocol reduced the inter-laboratory variation observed for ELISPOT and multimer analyses by approximately 20 %. We further demonstrate that results from ELISPOT and multimer staining correlated after (P < 0.0001 and R (2) = 0.5113), but not before IVS. In summary, IVS was shown to be a reproducible method that benefitted from method harmonisation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Linfocitos T CD8-positivos / Ensayo de Immunospot Ligado a Enzimas / Antígenos HLA Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Humans País/Región como asunto: Europa Idioma: En Revista: Cancer Immunol Immunother Asunto de la revista: ALERGIA E IMUNOLOGIA / NEOPLASIAS / TERAPEUTICA Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Linfocitos T CD8-positivos / Ensayo de Immunospot Ligado a Enzimas / Antígenos HLA Tipo de estudio: Clinical_trials / Diagnostic_studies Límite: Humans País/Región como asunto: Europa Idioma: En Revista: Cancer Immunol Immunother Asunto de la revista: ALERGIA E IMUNOLOGIA / NEOPLASIAS / TERAPEUTICA Año: 2014 Tipo del documento: Article