Your browser doesn't support javascript.
loading
Benefits of fresh-frozen plasma as a replacement fluid to neutralize ABO antibodies.
Won, Dong Il; Ham, Ji Yeon; Kim, Chan Duck; Suh, Jang Soo; Kim, Byung Chang.
Afiliación
  • Won DI; Department of Clinical Pathology, Kyungpook National University School of Medicine, Daegu, Republic of Korea.
  • Ham JY; Department of Clinical Pathology, Kyungpook National University School of Medicine, Daegu, Republic of Korea.
  • Kim CD; Department of Internal Medicine, Kyungpook National University School of Medicine, Daegu, Republic of Korea.
  • Suh JS; Department of Clinical Pathology, Kyungpook National University School of Medicine, Daegu, Republic of Korea.
  • Kim BC; Department of Laboratory Medicine, Maryknoll Medical Center, Busan, Republic of Korea.
J Clin Apher ; 30(5): 288-96, 2015 Oct.
Article en En | MEDLINE | ID: mdl-25546477
ABSTRACT

BACKGROUND:

ABO-incompatible organ transplantation requires pre-transplant conditioning to reduce ABO antibody levels in the recipients. With respect to replacement fluids used in plasma exchange, we intended to verify whether fresh-frozen plasma (FFP) containing soluble ABO substance (SAS) is more effective than albumin solution in reducing ABO IgG antibody levels.

METHODS:

Apheresis data were retrospectively studied for in vivo effects, and in vitro plasma mixing studies were prospectively performed. The amount of ABO IgG antibodies bound to red cells was measured as the mean fluorescence intensity (MFI) using flow cytometry. Neutralization of ABO antibodies in the recipientst plasma by an ABO-incompatible donornc plasma was measured using the inhibition assay principle. The MFI value of the unneutralized control tube was divided by that of the neutralized test tube (neutralizing-capacity index, NCI).

RESULTS:

The plasma exchange procedures replaced with group AB FFP showed a significantly greater decreased titer than those replaced with albumin (P = 0.010). The in vitro plasma mixing study simulating plasma exchange also produced consistent results. When the pooled group O plasma was neutralized for anti-A by individual group AB plasmas (AB-to-O, N = 30), the NCI was 12.8 ± 5.4 (6.5-29.5). When this group O plasma was neutralized by pooled group AB or A plasma, the repeatedly measured NCI (N = 5) of A-to-O (11.4 ± 1.4) was not significantly different from that of AB-to-O (9.7 ± 1.3, P = 0.074).

CONCLUSIONS:

ABO antibody levels are reduced more effectively by group AB FFP than by albumin. Either group AB or donor type (group A or B) FFP can be infused to group O recipients. FFP units with higher SAS levels can be selected from multiple available candidate units using our protocol for measuring the neutralizing-capacity.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Plasma / Intercambio Plasmático / Incompatibilidad de Grupos Sanguíneos / Sistema del Grupo Sanguíneo ABO / Inmunoglobulina G / Sustitutos del Plasma / Acondicionamiento Pretrasplante / Isoanticuerpos Tipo de estudio: Evaluation_studies / Observational_studies Límite: Humans País/Región como asunto: Asia Idioma: En Revista: J Clin Apher Año: 2015 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Plasma / Intercambio Plasmático / Incompatibilidad de Grupos Sanguíneos / Sistema del Grupo Sanguíneo ABO / Inmunoglobulina G / Sustitutos del Plasma / Acondicionamiento Pretrasplante / Isoanticuerpos Tipo de estudio: Evaluation_studies / Observational_studies Límite: Humans País/Región como asunto: Asia Idioma: En Revista: J Clin Apher Año: 2015 Tipo del documento: Article