ABSTRACT
BACKGROUND AND PURPOSE:
ECG screening of young athletes for risk of sudden cardiac death has grown in popularity throughout the world. The purpose of this study is to assess the technical error rate of ECGs acquired by appropriately trained community volunteers compared to that reported in the literature utilizing trained medical personnel.METHODS:
This is a retrospective study analyzing consecutive ECGs acquired during 5 successive high school screenings at 3 separate schools in 2011.RESULTS:
A total of 4477 consecutive ECGs were acquired and assessed for technical quality. The total rate of technically inadequate tracings was 0.34%. This is lower than that reported in outpatient clinics acquired by medically trained technicians (0.4%) and in ICUs acquired by nurses (4.8%).CONCLUSIONS:
This study demonstrates that the ECG training program utilized by the YH4L program for community volunteers results in a technical error rate that is lower than reported in the literature.Palabras clave
Texto completo:
1
Colección:
01-internacional
Banco de datos:
MEDLINE
Asunto principal:
Competencia Clínica
/
Muerte Súbita Cardíaca
/
Agentes Comunitarios de Salud
/
Electrocardiografía
/
Técnicos Medios en Salud
/
Atletas
/
Enfermeras y Enfermeros
Tipo de estudio:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
/
Screening_studies
Límite:
Adult
/
Female
/
Humans
/
Male
País/Región como asunto:
America do norte
Idioma:
En
Revista:
J Electrocardiol
Año:
2015
Tipo del documento:
Article