Margin Reflex Distance: Differences Based on Camera and Flash Positions.
Choi, Catherine J; Chou, Jonathan C; Lefebvre, Daniel R; Yoon, Michael K.
Afiliación
  • Choi CJ; *Ophthalmic Plastic Surgery, Massachusetts Eye and Ear Infirmary; and †Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts, U.S.A.
Ophthalmic Plast Reconstr Surg ; 32(3): 199-203, 2016.
Article en En | MEDLINE | ID: mdl-25844505
ABSTRACT

PURPOSE:

To evaluate the effect of camera flash position on the measurement of photographic margin reflex distances (MRD).

METHODS:

Subjects without any ophthalmic disease were prospectively enrolled after institutional review board approval. Clinical measurements of MRD1 and interpalpebral fissure were obtained. Photographs were then taken with a digital single lens reflex with built-in pop-up flash (dSLR-pop), a dSLR with lens-mounted ring flash (dSLR-ring), a point-and-shoot camera, and a smartphone, each in 4 positions with the camera upright, rotated 90°, 180°, and 270°. The images were analyzed using ImageJ software to measure MRD1, interpalpebral fissure, horizontal white-to-white, and distance from nasal limbus to the corneal light reflex.

RESULTS:

Thirty-two eyes of 16 subjects were included (ages 27-65). When using the dSLR-ring, point-and-shoot, and smartphone, the difference between clinical and photographic MRD1 did not reach statistical significance. There was, however, a statistically significant difference in the upright position with dSLR-pop (mean difference 0.703 mm, σ = 0.984 mm, p = 0.0008). For dSLR-pop, photographic MRD1 in upright versus inverted position differed significantly (mean difference -0.562 mm, σ =0.348 mm, p < 0.0001). Photographic MRD1 between dSLR-pop and dSLR-ring showed significant difference in upright position (mean difference -0.572 mm, σ = 0.701 mm, p = 0.0002). There were no statistically significant differences between clinical and photographic interpalpebral fissure, and among white-to-white and nasal limbus to light reflex measurements in any position in all 4 cameras.

CONCLUSIONS:

When using photographs for measurement of MRD1, cameras with a near-coaxial light source and aperture have values that are most similar to clinical measurements.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Parpadeo / Programas Informáticos / Fotograbar / Córnea / Oftalmopatías / Luz Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ophthalmic Plast Reconstr Surg Asunto de la revista: OFTALMOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Parpadeo / Programas Informáticos / Fotograbar / Córnea / Oftalmopatías / Luz Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ophthalmic Plast Reconstr Surg Asunto de la revista: OFTALMOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Estados Unidos