Clinical utility of dual-energy contrast-enhanced spectral mammography for breast microcalcifications without associated mass: a preliminary analysis.
Cheung, Yun-Chung; Tsai, Hsiu-Pei; Lo, Yung-Feng; Ueng, Shir-Hwa; Huang, Pei-Chin; Chen, Shin-Chih.
Afiliación
  • Cheung YC; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Tao Yuan and Linkuo, Medical College of Chang Gung University, 5 Fuxing Street, Guishan Township, Taoyuan County, Taiwan. alex2143@ms33.hinet.net.
  • Tsai HP; Medical Collage of Chang Gung University, Taoyuan, Taiwan. alex2143@ms33.hinet.net.
  • Lo YF; Department of Surgery, Chang Gung Memorial Hospital at Linkuo, Taoyuan, Taiwan.
  • Ueng SH; Medical Collage of Chang Gung University, Taoyuan, Taiwan.
  • Huang PC; Department of Surgery, Chang Gung Memorial Hospital at Linkuo, Taoyuan, Taiwan.
  • Chen SC; Medical Collage of Chang Gung University, Taoyuan, Taiwan.
Eur Radiol ; 26(4): 1082-9, 2016 Apr.
Article en En | MEDLINE | ID: mdl-26159872
ABSTRACT

OBJECTIVE:

To assess the utility of dual-energy contrast-enhanced spectral mammography (DE-CESM) for evaluation of suspicious malignant microcalcifications.

METHODS:

Two hundred and fifty-six DE-CESMs were reviewed from 2012-2013, 59 cases fulfilled the following criteria and were enrolled for

analysis:

(1) suspicious malignant microcalcifications (BI-RADS 4) on mammogram, (2) no related mass, (3) with pathological diagnoses. The microcalcification morphology and associated enhancement were reviewed to analyse the accuracy of the diagnosis and cancer size measurements versus the results of pathology.

RESULTS:

Of the 59 microcalcifications, 22 were diagnosed as cancers, 19 were atypical lesions and 18 were benign lesions. Twenty (76.9 %) cancers, three (11.55 %) atypia and three (11.55 %) benign lesions revealed enhancement. The true-positive rate of intermediate- and high-concern microcalcifications was significantly higher than that of low-concern lesions (93.75 % vs. 50 %). Overall, the diagnostic sensitivity of enhancement was 90.9 %, with 83.78 % specificity, 76.92 % positive predictive value, 93.94 % negative predictive value and 86.4 % accuracy. Performance was good (AUC = 0.87) according to a ROC curve and cancer size correlation with a mean difference of 0.05 cm on a Bland-Altman plot.

CONCLUSIONS:

DE-CESM provides additional enhancement information for diagnosing breast microcalcifications and measuring cancer sizes with high correlation to surgicohistology. KEY POINTS • DE-CESM provides additional enhancement information for diagnosing suspicious breast microcalcifications. • The enhanced cancer size closely correlates to microscopy by Bland-Altman plot. • DE-CESM could be considered for evaluation of suspicious malignant microcalcifications.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Mamografía / Intensificación de Imagen Radiográfica / Medios de Contraste Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Neoplasias de la Mama / Mamografía / Intensificación de Imagen Radiográfica / Medios de Contraste Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Taiwán