Note: Upgrade of electron cyclotron emission imaging system and preliminary results on HL-2A tokamak.
Jiang, M; Shi, Z B; Domier, C W; Luhmann, N C; Zhong, W L; Chen, W; Liu, Z T; Ding, X T; Yang, Q W; Zhang, B Y; Yang, Z C; Shi, P W; Liu, Y; Fu, B Z; Xu, Y.
Afiliación
  • Jiang M; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Shi ZB; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Domier CW; Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA.
  • Luhmann NC; Department of Electrical and Computer Engineering, University of California, Davis, California 95616, USA.
  • Zhong WL; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Chen W; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Liu ZT; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Ding XT; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Yang QW; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Zhang BY; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Yang ZC; School of Physics and Chemistry, Xihua University, Chengdu 610039, China.
  • Shi PW; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Liu Y; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Fu BZ; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Xu Y; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
Rev Sci Instrum ; 86(7): 076107, 2015 Jul.
Article en En | MEDLINE | ID: mdl-26233421
The electron cyclotron emission imaging system on the HL-2A tokamak has been upgraded to 24 (poloidally) × 16 (radially) channels based on the previous 24 × 8 array. The measurement region can be flexibly shifted due to the independence of the two local oscillator sources, and the field of view can be adjusted easily by changing the position of the zoom lenses. The temporal resolution is about 2.5 µs and the achievable spatial resolution is 1 cm. After laboratory calibration, it was installed on HL-2A tokamak in 2014, and the local 2D mode structures of MHD activities were obtained for the first time.